radiostereometric analysis
Recently Published Documents


TOTAL DOCUMENTS

200
(FIVE YEARS 48)

H-INDEX

26
(FIVE YEARS 4)

2022 ◽  
pp. 212-221
Author(s):  
Ruben Y Kok ◽  
Lennard A Koster ◽  
Bart L Kaptein ◽  
Marta Fiocco ◽  
Stefan B Keizer

Background and purpose – The Taperloc Complete hip is the successor of the Taperloc hip, aiming to increase range of motion and optimizing femoral fit with intermediate stem sizes. We evaluated whether these design changes affect fixation, and this RSA study compares 2-year migration. Patients and methods – In this prospective, multi-arm study, 100 patients were randomized to cementless total hip arthroplasty (THA) with Taperloc Complete full profile (TCFP), Taperloc Complete reduced distal (TCRD), Taperloc full profile (TFP), or Taperloc reduced distal (TRD). Migration was measured with model-based RSA postoperatively, and after 3, 12, and 24 months. Results – Results based on mixed-model analysis on 2-year postoperative RSA data from 74 patients showed similar subsidence (mm) in the first 3 months (mean [95% CI] TCFP 0.44 [0.20–0.69], TCRD 0.91 [0.40–1.42], TFP 0.71 [0.22–1.19], TRD 1.25 [0.58–1.91]) and stabilization afterwards. The TCFP showed statistically significantly less retroversion (°) at 2-year postoperatively compared with TFP and TCRD (mean [95% CI] TCFP: –0.13 [–0.64 to 0.38], TCRD: 0.84 [0.35–1.33], TFP: 0.56 [0.12–1.00], TRD: 0.37 [–0.35 to 1.09]). Interpretation – As expected in successful cementless THA, RSA shows stabilization after initial subsidence. Based on these results the Taperloc Complete stem is expected to have similar long-term fixation to the Taperloc stems. The reduced distal groups have larger, but statistically non-significant, initial migration compared with the TCFP group, which could be due to implantation in Dorr B, C femur types. It may be important to consider the femur shape for choosing a full profile or reduced distal stem to minimize migration.


2022 ◽  
pp. 206-211
Author(s):  
Andreas Nyström ◽  
Demostenis Kiritopoulos ◽  
Hans Mallmin ◽  
Stergios Lazarinis

Background and purpose — We previously described a decrease in bone mineral density (BMD) in the calcar region 2 years after insertion of the collum femoris-preserving (CFP) stem, but the implants were stable. Now we have examined the long-term changes in periprosthetic BMD and stability of the CFP stem. Patients and methods — We conducted a minimum 8-year follow-up of 21 patients from our original investigation. We examined periprosthetic BMD by dual-energy X-ray absorptiometry (DEXA) and implant stability by radiostereometric analysis (RSA). Results — Between 2 and 8 years 1 stem was revised due to aseptic loosening. Between 2 and 8 years we found a 14% (95% confidence interval [CI] 9–19) reduction in BMD in Gruen zone 6 and 17% (CI 6–28) in Gruen zone 7. From baseline the reduction in BMD was 30% (CI 23–36) in Gruen zone 6, 39% (CI 31–47) in Gruen zone 7, and 19% (CI 14–23) in Gruen zone 2. Between 2 and 8 years, RSA (n = 17) showed a mean translation along the stem axis of 0.02mm (CI –0.02 to 0.06) and a mean rotation around the stem axis of 0.08° (CI –0.26 to 0.41). From baseline mean subsidence was 0.07 mm (CI –0.16 to 0.03) and mean rotation around the stem axis was 0.23° (CI –0.23 to 0.68) at 8 years. Interpretation — There was continuous loss of proximomedial BMD at 8 years while the CFP stem remained stable. Proximal periprosthetic bone loss cannot be prevented by this stem.


2021 ◽  
pp. 112070002198999
Author(s):  
Volker Otten ◽  
Daniel Wästerlund ◽  
John Lindbjörn ◽  
Carl Mertens ◽  
Sebastian Mukka ◽  
...  

Background and purpose: The aim of this prospective, randomised and controlled study was to evaluate the wear and fixation properties of a new cemented highly cross-linked all-polyethylene (HXLPE) cup in comparison with a conventional cemented ultra-high molecular weight polyethylene (ConvPE) cup using radiostereometric analysis (RSA). Patients and methods: A total of 58 patients (58 hips) with primary osteoarthritis (OA) were enrolled in a randomised controlled trial to receive either a ConvPE cup (control) or HXLPE cup (intervention) with identical geometry. The subjects were randomised in a 1:1 ratio. The primary endpoint was proximal wear measured as femoral head penetration into the cup, secondary outcomes were 3D-wear and annual proximal wear from 1 to 5 years. Cup fixation was measured as movement of the cup in relation to the acetabular bone with proximal migration being the primary outcome measure, 3D-migration and change in inclination as secondary outcomes. The patients were followed for 5 years with RSA performed postoperatively, at 3, 12, 24, and 60 months. Results: The HXLPE displayed a lower median proximal femoral head penetration compared to ConvPE, with a median difference at 2 years of –0.07 mm (95% CI, –0.10 to –0.04 mm), and –0.19 mm (95% CI, –0.27 to –0.15 mm) at 5 years. Annual proximal wear between 1 and 5 years was 0.03 mm/year for HXLPE and 0.06 mm/year for ConvPE (mean difference 0.05 mm, [95% CI, 0.03–0.07 mm]). Proximal migration, 3D migration and change in inclination was numerically slightly higher for HXLPE, albeit not statistically significant. Conclusions: Compared to ConvPE, the HXLPE cup displayed significantly lower polyethylene wear. Cup migration was not statistically significant different. ClinicalTrials.gov Identifier: NCT04322799.