radius fractures
Recently Published Documents


TOTAL DOCUMENTS

2471
(FIVE YEARS 740)

H-INDEX

62
(FIVE YEARS 9)

2022 ◽  
Vol 1 (1) ◽  
pp. 1-8
Author(s):  
Alejandro Alvarez López

Background: Distal radius fractures are frequent in emergency departments, treatment is generally conservative, but there are patients who meet certain criteria of instability who need surgical treatment, including external fixation. Aim: To update on the most important elements regarding the use of external fixation in unstable fractures of the distal radius. Methods: The search and analysis of the information was carried out in a period of 30 days (from April 1 to April 30, 2021) and the following words were used: distal radius fractures, distal radius fractures and external fixation and unstable radius fractures from the information obtained, a bibliographic review of a total of 809 articles published in the PubMed databases, Hinari, SciELO and Medline was carried out using the search manager and EndNote reference manager, of which 44 selected citations were used to perform the review, 37 from the last five years. Development: The criteria to be taken into account for the instability described by various authors are indicated, as well as the imaging parameters. The two most used classification systems are mentioned. Reference is made to general surgical indications, external fixation, and placement of additional wires. Complications are discussed and a comparison is made between external fixation and blocked volar plates.


Author(s):  
Ha Sung Park ◽  
Shin Woo Choi ◽  
Joo-Yul Bae

Purpose: During volar plate fixation of distal radius fractures, we have encountered patients with an anomalous course of the palmar cutaneous branch (PCB) of the median nerve within the sheath of the flexor carpi radialis (FCR) tendon. The purpose of this study was to assess the frequency and location of variations of the PCB within the sheath of the FCR tendon.Methods: This retrospective study enrolled 83 patients who underwent volar locking plate fixations through a modified Henry approach for distal radius fractures from July 2018 to April 2020. When we encountered an anomalous PCB within the sheath of the FCR tendon, we documented the specific finding and location where the PCB entered the sheath of the FCR tendon.Results: There were nine patients (10.8%) who had an anomalous course of PCB penetrating the sheath of the FCR tendon. The average entering point of PCB into the sheath of the FCR tendon was 3.07 cm from the distal wrist crease (range, 2.5–3.6 cm).Conclusion: An anomalous course of the PCB entering the sheath of the FCR tendon was observed at a high frequency (10.8%). Care must be taken not to injure the PCB during a dissecting of the FCR sheath during a modified Henry approach for a distal radius fracture.


Author(s):  
Simon Sun ◽  
Christian Geannette ◽  
Natalie Braun ◽  
Scott W. Wolfe ◽  
Yoshimi Endo

2022 ◽  
Vol 23 (1) ◽  
Author(s):  
Mariya Hadzhinikolova ◽  
Ivan Zderic ◽  
Daniel Ciric ◽  
Jan P. Barcik ◽  
Dian Enchev ◽  
...  

AbstractComplex intraarticular distal radius fractures (DRFs), commonly managed with volar locking plates, are challenging. Combined volar and dorsal plating is frequently applied for treatment, however, biomechanical investigations are scant. The aim of this biomechanical study was to investigate volar plating versus double plating in DRFs with different degrees of lunate facet comminution.Thirty artificial radii with simulated AO/OTA 23-C2.1 and C3.1 DRFs, including dorsal defect and lunate facet comminution, were assigned to 3 groups: Group 1 with two equally-sized lunate facet fragments; Group 2 with small dorsal and large volar fragment; Group 3 with three equally-sized fragments. The specimens underwent volar and double locked plating and non-destructive ramped loading in 0° neutral position, 40° flexion and 40° extension.In each tested position, stiffness: (1) did not significantly differ among groups with same fixation method (p ≥ 0.15); (2) increased significantly after supplemental dorsal plating in Group 2 and Group 3 (p ≤ 0.02).Interfragmentary displacements between styloid process and lunate facet in neutral position were below 0.5 mm, being not significantly different among groups and plating techniques (p ≥ 0.63).Following volar plating, angular displacement of the lunate facet to radius shaft was significantly lower in Group 1 versus both Group 2 and Group 3 (p < 0.01). It decreased significantly after supplemental dorsal plating in Group 2 and Group 3 (p < 0.01), but not in Group 1 (p ≥ 0.13), and did not differ significantly among the three groups after double plating (p ≥ 0.74).Comminution of the lunate facet within its dorsal third significantly affected the biomechanical outcomes related to complex intraarticular DRFs treated with volar and double locked plates.Double plating demonstrates superior stability versus volar plating only for lunate facet comminution within its dorsal third. In contrast, volar plating could achieve stability comparable with double plating when the dorsal third of the lunate facet is not separated by the fracture pattern. Both fixation methods indicated achievable absolute stability between the articular fragments.


2022 ◽  
Vol 23 (1) ◽  
Author(s):  
Yin-Ming Huang ◽  
Chun-Yu Chen ◽  
Kai-Cheng Lin ◽  
Yih-Wen Tarng ◽  
Ching-Yi Liao ◽  
...  

Abstract Introduction The volar locking plate has been widely used for unstable distal radius fractures to provide early recovery of wrist function. Volar plate prominence to the watershed line has been reported to be related to flexor tendon irritation, and avoid implant prominence in this area was suggested. On the other hand, marginal distal radius fracture patterns required the plate to cross the watershed line, making conflict over plate positioning on marginal distal radius fractures. This study compared functional outcomes in patients with marginal distal radius fractures treated with two different implants. Materials and methods A retrospective study was conducted, all patients who received a Synthes 2.4 mm LCP or an Acumed Acu-Loc VLP between January 2015 and December 2018 were reviewed. The marginal distal radius fracture pattern was the most distal horizontal fracture line within 10 mm of the lunate fossa’s joint line. The primary outcomes including patient-reported pain scores, range of motion, and grip strength were assessed. Secondary outcomes included patient-based subjective satisfaction scores of the injured wrist and hand function. The Mayo Wrist Score and the requirement for a secondary procedure related to hardware complications were also recorded. Results Forty-two patients met our inclusion criteria. Twenty-one patients were treated with the Synthes 2.4 mm LCP, and 21 patients with the Acumed Acu-Loc VLP. The primary outcome revealed that post-operative range of motion (P = 0.016) and grip strengths (P = 0.014) were significantly improved in the Acu-Loc VLP group. The MAYO wrist score in the Acu-Loc VLP group was also significantly better (P = 0.006). Conclusions Despite advances in implant designs, flexor tendon irritation or rupture is still a complication following distal radius’s volar plating. We believe the Acumed Acu-Loc VLP design provided better functional outcomes than the Synthes 2.4 mm LCP if appropriately and carefully placed into its designed-for position. This positioning results in promising patient satisfaction when treating marginal distal radius fractures.


2022 ◽  
pp. 470-484
Author(s):  
Daniel A. London ◽  
Ryan P. Calfee

2022 ◽  
Vol 86 (1) ◽  
pp. 372-378
Author(s):  
Abdelsalam Eid Abdelsala ◽  
Osam Mohammed Metwally ◽  
Salah Mahmoud Abd El Kader ◽  
Emad Mohammed Ali Alfirjani

Sign in / Sign up

Export Citation Format

Share Document