axon diameter
Recently Published Documents


TOTAL DOCUMENTS

112
(FIVE YEARS 28)

H-INDEX

35
(FIVE YEARS 5)

Author(s):  
Sheryl L. Herrera ◽  
Maxina Sheft ◽  
Morgan E. Mercredi ◽  
Richard Buist ◽  
Kant M. Matsuda ◽  
...  

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Cody L. Call ◽  
Dwight E. Bergles

ABSTRACTAxons in the cerebral cortex show a broad range of myelin coverage. Oligodendrocytes establish this pattern by selecting a cohort of axons for myelination; however, the distribution of myelin on distinct neurons and extent of internode replacement after demyelination remain to be defined. Here we show that myelination patterns of seven distinct neuron subtypes in somatosensory cortex are influenced by both axon diameter and neuronal identity. Preference for myelination of parvalbumin interneurons was preserved between cortical areas with varying myelin density, suggesting that regional differences in myelin abundance arises through local control of oligodendrogenesis. By imaging loss and regeneration of myelin sheaths in vivo we show that myelin distribution on individual axons was altered but overall myelin content on distinct neuron subtypes was restored. Our findings suggest that local changes in myelination are tolerated, allowing regenerated oligodendrocytes to restore myelin content on distinct neurons through opportunistic selection of axons.


2021 ◽  
Vol 15 ◽  
Author(s):  
Takeshi Shimizu ◽  
Hideji Murakoshi ◽  
Hidetoshi Matsumoto ◽  
Kota Ichino ◽  
Atsunori Hattori ◽  
...  

Oligodendrocytes (OLs) form a myelin sheath around neuronal axons to increase conduction velocity of action potential. Although both large and small diameter axons are intermingled in the central nervous system (CNS), the number of myelin wrapping is related to the axon diameter, such that the ratio of the diameter of the axon to that of the entire myelinated-axon unit is optimal for each axon, which is required for exerting higher brain functions. This indicates there are unknown axon diameter-dependent factors that control myelination. We tried to investigate physical factors to clarify the mechanisms underlying axon diameter-dependent myelination. To visualize OL-generating forces during myelination, a tension sensor based on fluorescence resonance energy transfer (FRET) was used. Polystyrene nanofibers with varying diameters similar to neuronal axons were prepared to investigate biophysical factors regulating the OL-axon interactions. We found that higher tension was generated at OL processes contacting larger diameter fibers compared with smaller diameter fibers. Additionally, OLs formed longer focal adhesions (FAs) on larger diameter axons and shorter FAs on smaller diameter axons. These results suggest that OLs respond to the fiber diameter and activate mechanotransduction initiated at FAs, which controls their cytoskeletal organization and myelin formation. This study leads to the novel and interesting idea that physical factors are involved in myelin formation in response to axon diameter.


PLoS ONE ◽  
2021 ◽  
Vol 16 (7) ◽  
pp. e0248323
Author(s):  
Alison L. Wong ◽  
Nicholas Hricz ◽  
Harsha Malapati ◽  
Nicholas von Guionneau ◽  
Michael Wong ◽  
...  

Background Manual axon histomorphometry (AH) is time- and resource-intensive, which has inspired many attempts at automation. However, there has been little investigation on implementation of automated programs for widespread use. Ideally such a program should be able to perform AH across imaging modalities and nerve states. AxonDeepSeg (ADS) is an open source deep learning program that has previously been validated in electron microscopy. We evaluated the robustness of ADS for peripheral nerve axonal histomorphometry in light micrographs prepared using two different methods. Methods Axon histomorphometry using ADS and manual analysis (gold-standard) was performed on light micrographs of naïve or regenerating rat median nerve cross-sections prepared with either toluidine-resin or osmium-paraffin embedding protocols. The parameters of interest included axon count, axon diameter, myelin thickness, and g-ratio. Results Manual and automatic ADS axon counts demonstrated good agreement in naïve nerves and moderate agreement on regenerating nerves. There were small but consistent differences in measured axon diameter, myelin thickness and g-ratio; however, absolute differences were small. Both methods appropriately identified differences between naïve and regenerating nerves. ADS was faster than manual axon analysis. Conclusions Without any algorithm retraining, ADS was able to appropriately identify critical differences between naïve and regenerating nerves and work with different sample preparation methods of peripheral nerve light micrographs. While there were differences between absolute values between manual and ADS, ADS performed consistently and required much less time. ADS is an accessible and robust tool for AH that can provide consistent analysis across protocols and nerve states.


2021 ◽  
Vol 15 ◽  
Author(s):  
Muhamed Barakovic ◽  
Gabriel Girard ◽  
Simona Schiavi ◽  
David Romascano ◽  
Maxime Descoteaux ◽  
...  

In the central nervous system of primates, several pathways are characterized by different spectra of axon diameters. In vivo methods, based on diffusion-weighted magnetic resonance imaging, can provide axon diameter index estimates non-invasively. However, such methods report voxel-wise estimates, which vary from voxel-to-voxel for the same white matter bundle due to partial volume contributions from other pathways having different microstructure properties. Here, we propose a novel microstructure-informed tractography approach, COMMITAxSize, to resolve axon diameter index estimates at the streamline level, thus making the estimates invariant along trajectories. Compared to previously proposed voxel-wise methods, our formulation allows the estimation of a distinct axon diameter index value for each streamline, directly, furnishing a complementary measure to the existing calculation of the mean value along the bundle. We demonstrate the favourable performance of our approach comparing our estimates with existing histologically-derived measurements performed in the corpus callosum and the posterior limb of the internal capsule. Overall, our method provides a more robust estimation of the axon diameter index of pathways by jointly estimating the microstructure properties of the tissue and the macroscopic organisation of the white matter connectivity.


2021 ◽  
Author(s):  
Mariam Andersson ◽  
Marco Pizzolato ◽  
Hans Martin Kjer ◽  
Katrine Forum Skodborg ◽  
Henrik Lundell ◽  
...  

Noninvasive estimation of axon diameter with diffusion MRI holds potential to investigate the dynamic properties of the brain network and pathology of neurodegenerative diseases. Recent methods use powder averaging to account for complex white matter architectures, such as fibre crossing regions, but these have not been validated for real axonal geometries. Here, we present 120-313 μm long segmented axons from X-ray nano-holotomography volumes of a splenium and crossing fibre region of a vervet monkey brain. We show that the axons in the complex crossing fibre region, which contains callosal, association, and corticospinal connections, are larger and exhibit a wider distribution than those of the splenium region. To accurately estimate the axon diameter in these regions, therefore, sensitivity to a wide range of diameters is required. We demonstrate how the q-value, b-value, signal-to-noise ratio and the assumed intra-axonal parallel diffusivity influence the range of measurable diameters with powder average approaches. Furthermore, we show how Gaussian distributed noise results in a wider range of measurable diameter at high b-values than with Rician distributed noise, even at high signal-to-noise ratios of 100. The number of gradient directions is also shown to impose a lower bound on measurable diameter. Our results indicate that axon diameter estimation can be performed with only few b-shells, and that additional shells do not improve the accuracy of the estimate. Through Monte Carlo simulations of diffusion, we show that powder averaging techniques succeed in providing accurate estimates of axon diameter across a range of sequence parameters and diffusion times, even in complex white matter architectures. At sufficiently low b-values, the acquisition becomes sensitive to axonal microdispersion and the intra-axonal parallel diffusivity shows time dependency at both in vivo and ex vivo intrinsic diffusivities.


2021 ◽  
pp. 1-11
Author(s):  
Zehra Çınar ◽  
Ufuk Emre ◽  
Mehmet Gül ◽  
Özgür Yiğit ◽  
Elshan Mammadov ◽  
...  

Objective: The aim of this study was to investigate the effects of systemic administration of decorin (DC) on facial nerve (FN) regeneration. Methods: A total of 32 female albino Wistar rats were divided into 4 groups: control (C) group: no bilateral FN neurorrhaphy (B-FNN), no DC application, sham-operated group: B-FNN without DC application, DC group: DC application without B-FNN, and B-FNN + DC group: B-FNN and DC application. Nerve conduction studies were performed before and after skin incisions at 1st, 3rd, 5th, and 7th weeks in all groups. The amplitude and latency of compound muscle action potentials were recorded. FN samples were obtained and were investigated under light microscopy and immunohistochemical staining. The nerve and axon diameter, number of axons, H score, Schwann cell proliferation, and myelin and axonal degeneration were recorded quantitatively. Results: In the sham group, the 3rd and 5th postoperative week, amplitude values were significantly lower than those of the B-FNN + DC group (p < 0.05). Nerve diameters were found to be significantly larger in the sham, DC, and B-FNN + DC groups than in the C group (p < 0.05). The number of axons, the axon diameter, and the H scores were found to be significantly higher in the B-FNN + DC group than in the sham group (p < 0.05). The Schwann cell proliferation, myelin degeneration, and axonal degeneration scores were significantly lower in the B-FNN + DC group than in the sham group (p < 0.05). Conclusion: Electrophysiological and histopathological evaluation revealed the potential benefits provided by DC. This agent may increase FN regeneration.


2021 ◽  
Author(s):  
Alison L. Wong ◽  
Nicholas Hricz ◽  
Harsha Malapati ◽  
Nicholas von Guionneau ◽  
Michael Wong ◽  
...  

AbstractBackgroundManual axon histomorphometry (AH) is time- and resource-intensive, which has inspired many attempts at automation. However, there has been little investigation on implementation of automated programs for widespread use. Ideally such a program should be able to perform AH across imaging modalities and nerve states. AxonDeepSeg (ADS) is an open source deep learning program that has previously been validated in electron microscopy. We evaluated the robustness of ADS for peripheral nerve axonal histomorphometry in light micrographs prepared using two different methods.MethodsAxon histomorphometry using ADS and manual analysis (gold-standard) was performed on light micrographs of naïve or regenerating rat median nerve cross-sections prepared with either toluidine-resin or osmium-paraffin embedding protocols. The parameters of interest included axon count, axon diameter, myelin thickness, and g-ratio.ResultsManual and automatic ADS axon counts demonstrated good agreement in naïve nerves and moderate agreement on regenerating nerves. There were small but consistent differences in measured axon diameter, myelin thickness and g-ratio; however, absolute differences were small. Both methods appropriately identified differences between naïve and regenerating nerves. ADS was faster than manual axon analysis.ConclusionsWithout any algorithm retraining, ADS was able to appropriately identify critical differences between naïve and regenerating nerves and work with different sample preparation methods of peripheral nerve light micrographs. While there were differences between absolute values between manual and ADS, ADS performed consistently and required much less time. ADS is an accessible and robust tool for AH that can provide consistent analysis across protocols and nerve states.


2020 ◽  
Vol 117 (52) ◽  
pp. 33649-33659
Author(s):  
Mariam Andersson ◽  
Hans Martin Kjer ◽  
Jonathan Rafael-Patino ◽  
Alexandra Pacureanu ◽  
Bente Pakkenberg ◽  
...  

Axonal conduction velocity, which ensures efficient function of the brain network, is related to axon diameter. Noninvasive, in vivo axon diameter estimates can be made with diffusion magnetic resonance imaging, but the technique requires three-dimensional (3D) validation. Here, high-resolution, 3D synchrotron X-ray nano-holotomography images of white matter samples from the corpus callosum of a monkey brain reveal that blood vessels, cells, and vacuoles affect axonal diameter and trajectory. Within single axons, we find that the variation in diameter and conduction velocity correlates with the mean diameter, contesting the value of precise diameter determination in larger axons. These complex 3D axon morphologies drive previously reported 2D trends in axon diameter and g-ratio. Furthermore, we find that these morphologies bias the estimates of axon diameter with diffusion magnetic resonance imaging and, ultimately, impact the investigation and formulation of the axon structure–function relationship.


Sign in / Sign up

Export Citation Format

Share Document