multispectral mri
Recently Published Documents


TOTAL DOCUMENTS

53
(FIVE YEARS 3)

H-INDEX

14
(FIVE YEARS 1)

Author(s):  
Andrea Chiappiniello ◽  
Roberto Tarducci ◽  
Cristina Muscio ◽  
Maria Grazia Bruzzone ◽  
Marco Bozzali ◽  
...  

AbstractAccurate and reproducible automated segmentation of human hippocampal subfields is of interest to study their roles in cognitive functions and disease processes. Multispectral structural MRI methods have been proposed to improve automated hippocampal subfield segmentation accuracy, but the reproducibility in a multicentric setting is, to date, not well characterized. Here, we assessed test–retest reproducibility of FreeSurfer 6.0 hippocampal subfield segmentations using multispectral MRI analysis pipelines (22 healthy subjects scanned twice, a week apart, at four 3T MRI sites). The harmonized MRI protocol included two 3D-T1, a 3D-FLAIR, and a high-resolution 2D-T2. After within-session T1 averaging, subfield volumes were segmented using three pipelines with different multispectral data: two longitudinal (“long_T1s” and “long_T1s_FLAIR”) and one cross-sectional (“long_T1s_FLAIR_crossT2”). Volume reproducibility was quantified in magnitude (reproducibility error—RE) and space (DICE coefficient). RE was lower in all hippocampal subfields, except for hippocampal fissure, using the longitudinal pipelines compared to long_T1s_FLAIR_crossT2 (average RE reduction of 0.4–3.6%). Similarly, the longitudinal pipelines showed a higher spatial reproducibility (1.1–7.8% of DICE improvement) in all hippocampal structures compared to long_T1s_FLAIR_crossT2. Moreover, long_T1s_FLAIR provided a small but significant RE improvement in comparison to long_T1s (p = 0.015), whereas no significant DICE differences were found. In addition, structures with volumes larger than 200 mm3 had better RE (1–2%) and DICE (0.7–0.95) than smaller structures. In summary, our study suggests that the most reproducible hippocampal subfield FreeSurfer segmentations are derived from a longitudinal pipeline using 3D-T1s and 3D-FLAIR. Adapting a longitudinal pipeline to include high-resolution 2D-T2 may lead to further improvements.


Radiology ◽  
2019 ◽  
Vol 291 (2) ◽  
pp. 351-357 ◽  
Author(s):  
Cristina Chirizzi ◽  
Davide De Battista ◽  
Ilaria Tirotta ◽  
Pierangelo Metrangolo ◽  
Giancarlo Comi ◽  
...  

2018 ◽  
Vol 9 ◽  
Author(s):  
Stefan Winzeck ◽  
Arsany Hakim ◽  
Richard McKinley ◽  
José A. A. D. S. R. Pinto ◽  
Victor Alves ◽  
...  

Author(s):  
Zoltán Kapás ◽  
László Lefkovits ◽  
David Iclănzan ◽  
Ágnes Győrfi ◽  
Barna László Iantovics ◽  
...  

2017 ◽  
Vol 35 ◽  
pp. 250-269 ◽  
Author(s):  
Oskar Maier ◽  
Bjoern H. Menze ◽  
Janina von der Gablentz ◽  
Levin Häni ◽  
Mattias P. Heinrich ◽  
...  

2016 ◽  
Vol 36 (4) ◽  
pp. 470-484 ◽  
Author(s):  
Subhranil Koley ◽  
Ashwini Galande ◽  
Bhooshan Kelkar ◽  
Anup K. Sadhu ◽  
Debranjan Sarkar ◽  
...  

2016 ◽  
Vol 45 (1) ◽  
pp. 51-58 ◽  
Author(s):  
S. Sivaram Kaushik ◽  
Robin Karr ◽  
Matthew Runquist ◽  
Cathy Marszalkowski ◽  
Abhishiek Sharma ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document