rebound tonometer
Recently Published Documents


TOTAL DOCUMENTS

120
(FIVE YEARS 25)

H-INDEX

26
(FIVE YEARS 2)

2021 ◽  
Author(s):  
Kamolchanok Kerdchuchuen ◽  
Kingkarn Samathayanon ◽  
Pitchapa Phientong ◽  
Suprapha Chattraphirat ◽  
Orapun Jaturakan ◽  
...  

2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Shunsuke Nakakura ◽  
Ryo Asaoka ◽  
Etsuko Terao ◽  
Yuki Nagata ◽  
Yasuko Fukuma ◽  
...  

Abstract Background This study investigated the agreement between a new rebound tonometer, IC200, and IcarePRO and Goldmann applanation tonometry (GAT). Methods This was a prospective cross-sectional study. We measured the intraocular pressure (IOP) in 145 eyes of 145 glaucoma patients in the sitting position using GAT, IcarePRO, and IC200. IcarePRO and IC200 measurements were also obtained in the supine position. IC200 measurement was performed using two modes: single six (IC200-single) and automatic (IC200-continuous) six-measurements mode. Results All tonometers provided high reproducibility in both positions (all intraclass correlation coefficients > 0.90), although it was highest with GAT, followed by IC200-continuous and IC200-single and then IcarePRO. In the sitting position, the mean (± SD) IOPs of GAT, IcarePRO, IC200-single, and IC200-continuous were 14.5 ± 2.9 mmHg, 13.3 ± 3.2 mmHg, 11.6 ± 3.2 mmHg, and 11.5 ± 3.2 mmHg, respectively. IOPs measured with IcarePRO or IC200 were significantly lower than those with GAT, particularly in patients with low IOP. IOPs measured with all tonometers were significantly elevated in the supine position as compared with the sitting position, but this difference was significantly greater with IC200-single and IC200-continuous compared with IcarePRO. IOP elevation was significant in eyes without bleb versus those with bleb, but this finding was not observed when IOP was measured with IcarePRO. The IOPs of the single and continuous modes of IC200 were interchangeable in both positions. Conclusions GAT, IcarePRO, and IC200 had sufficiently high reproducibility, but measurements with IcarePRO may not be accurate in the supine position. Elevation of IOP in the supine position, especially in eyes with bleb, was more sensitively captured with IC200 than with IcarePRO. Trial registration Japan Clinical Trials Register, No. UMIN000039982.


2021 ◽  
Vol 62 (5) ◽  
pp. 665-673
Author(s):  
Jong-uk Lee ◽  
Kee Sup Park ◽  
Jaeyoung Kim ◽  
Sung Bok Lee ◽  
Yeon Hee Lee ◽  
...  
Keyword(s):  

2021 ◽  
pp. 1098612X2110059
Author(s):  
Houman Faghihi ◽  
Seyed Mehdi Rajaei ◽  
Hesam Ostadhasan ◽  
Hannah Emami Alagha

Objectives The aim of this study was to assess the effect of topical tetracaine hydrochloride 0.5% on intraocular pressure (IOP) in ophthalmologically normal cats. Methods Twenty domestic shorthair cats (40 eyes) were used in this study. Each cat was randomly allocated to one of two groups (treatment or control). Baseline IOP (T0) was measured in each cat, and then one drop of tetracaine hydrochloride 0.5% or artificial tears was administered into a randomly chosen eye of each cat in the treatment and control groups, respectively. Repeat IOP measurements were performed at 2 mins (T2), 5 mins (T5), 15 mins (T15) and 30 mins (T30) with a rebound tonometer. Results Mean baseline IOP in all eyes was 20.6 ± 2.5 mmHg. After the unilateral administration of tetracaine, mean IOP decreased significantly in the treated eye at T2 ( P = 0.01). Mean IOP returned to baseline values at T15. The mean IOPs in the treated eyes at T0, T2, T5, T15 and T30 were 20.6 ± 3.3 mmHg, 18.2 ± 2.5 mmHg, 18.2 ± 3.4 mmHg, 20.2 ± 3.2 mmHg and 19.8 ± 2.7 mmHg, respectively. A significant difference in IOP was found at all time points between the tetracaine and control groups (P <0.03). Conclusions and relevance The results of the present study showed a statistically significant reduction in mean IOP 2 mins after the administration of tetracaine hydrochloride 0.5% in the treated eyes of the cats.


2021 ◽  
Vol 14 (3) ◽  
pp. 405-408
Author(s):  
Eldar Rosenfeld ◽  
◽  
Dana Barequet ◽  
Michael Mimouni ◽  
Naomi Fischer ◽  
...  

AIM: To evaluate intraocular pressure (IOP) measurements and fluctuations using the iCare ONE rebound tonometer (RT-ONE), during home monitoring, in diagnosed and suspected glaucoma patients. METHODS: A retrospective case series of consecutive patients with known glaucoma or glaucoma suspects who were followed-up and treated between January 2016 and January 2017. The study included 80 eyes of 40 patients with a mean age of 59.1±14.6y (range, 24-78). All patients have undergone 4-5d of IOP home monitoring with RT-ONE at morning, noon, afternoon, and night time. RESULTS: Baseline mean IOP, as measured in the clinic (8 a.m.-12 p.m.), was 17.4±5.1 mm Hg, compared to RT-ONE home monitoring mean IOP of 15.6±4.1 mm Hg (P=0.002). Mean IOP was significantly lower at noon, afternoon and night times compared to clinic measured IOP and morning measurements (P=0.005). IOP peak measured during home monitoring was significantly higher compared to the clinic measured IOP (21.3±5.6 mm Hg and 17.4±5.1 mm Hg, P<0.001). IOP peaks during home monitoring demonstrated a majority of 47 peaks during morning measurements, compared to 23 at noon, 19 at afternoon and only 12 at night (P<0.001). The home monitoring results led to treatment modification of 44 eyes (55%), treatment regime was insufficient for 40 (50%) eyes. CONCLUSION: Home monitoring IOP with RT-ONE can provide good assessment of mean IOP, IOP fluctuations and peaks throughout the hours of the day, which lead to an accurate treatment for glaucoma patients.


2020 ◽  
Vol 50 (5) ◽  
pp. 271-274
Author(s):  
Dilek Uzlu ◽  
Nurettin Akyol ◽  
Adem Türk ◽  
Nurcan Gürsoy ◽  
Ahmet Mehmet Somuncu ◽  
...  

2020 ◽  
Author(s):  
Blanche D. Rodrigues ◽  
Fabiano Montiani‐Ferreira ◽  
Mariza Bortolini ◽  
André T. Somma ◽  
András M. Komáromy ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document