airway scope
Recently Published Documents


TOTAL DOCUMENTS

176
(FIVE YEARS 9)

H-INDEX

23
(FIVE YEARS 1)

2021 ◽  
pp. 102490792110342
Author(s):  
Christopher J Groombridge ◽  
Amit Maini ◽  
Joseph Mathew ◽  
Peter Fritz ◽  
Yesul Kim ◽  
...  

Background: After failed endotracheal intubation, using direct laryngoscopy, rescued using a supraglottic airway device, the choice of subsequent method to secure a definitive airway is not clearly determined. Objective: The aim of this study was to compare the time to intubation using a fibre-optic airway scope, to guide an endotracheal tube through the supraglottic airway device, with a more conventional approach using a hyperangulated video laryngoscope. Methods: A single-centre randomised controlled trial was undertaken. The population studied were emergency physicians working in an adult major trauma centre. The intervention was intubation through a supraglottic airway device guided by a fibre-optic airway scope. The comparison was intubation using a hyperangulated video laryngoscope. The primary outcome was time to intubation. The trial was registered with ANZCTR.org.au (ACTRN12621000018819). Results: Four emergency physicians completed intubations using both of the two airway devices on four cadavers for a total of 32 experiments. The mean time to intubation was 14.0 s (95% confidence interval = 11.1–16.8) in the hyperangulated video laryngoscope group compared with 29.2 s (95% confidence interval = 20.7–37.7) in the fibre-optic airway scope group; a difference of 15.2 s (95% confidence interval = 8.7–21.7, p < 0.001). All intubations were completed within 2 min, and there were no equipment failures or evidence of airway trauma. Conclusion: Successful intubation of the trachea without airway trauma by emergency physicians in cadavers is achievable by either fibre-optic airway scope via a supraglottic airway device or hyperangulated video laryngoscope. Hyperangulated video laryngoscope was statistically but arguably not clinically significantly faster than fibre-optic airway scope via supraglottic airway device.


2020 ◽  
Vol 2020 ◽  
pp. 1-3
Author(s):  
Koichi Nishikawa ◽  
Yoshihisa Fujita

We report on a case of mechanical damage to the spiral-filled polyvinyl chloride endotracheal tube that occurred shortly after tracheal intubation using a channeled videolaryngoscope (Pentax airway scope). We also found this problem in two other cases among 350 neurosurgery patients over the past 5 years. Prior to intubation, we did not observe any defect in the cuff. However, the cuff could not be filled with air immediately after the intubation. Anesthesiologists should be aware that, during tracheal intubation using an airway scope, friction between the endotracheal tube and inner surface of the introducer might result in sudden rupture of the cuff.


2019 ◽  
Author(s):  
Yoko Okumura ◽  
Masahiro Okuda ◽  
Aiji Sato (Boku) ◽  
Naoko Tachi ◽  
Mayumi Hashimoto ◽  
...  

Abstract Background: Airway Scope (AWS) with its plastic blade does not require a head-tilt or separate laryngoscopy to guide intubations. Therefore, we hypothesized that its use would reduce the intubation time (IT) and the frequency of airway complication events when compared with the use of Macintosh Laryngoscope (ML) for infants with cleft lip and palate (CLP). Methods: The parents of all patients provided written consents; we enrolled 40 infants with CLP (ASA-PS 1). After inducing general anesthesia using sevoflurane and rocuronium, we performed orotracheal intubations using either AWS (n = 20) or ML (n = 20), randomly. We define the duration between manual manipulation using cross finger for maximum mouth opening and the first raising motion of the chest following intubation by artificial ventilation as “IT;” further, the measured IT as primary outcomes. Airway complications were considered secondary outcomes. Moreover, we looked for associations between IT and the patient’s characteristics: extensive clefts, age, height, and weight. We used the Mann–Whitney test and Fisher’s exact probability test for statistical analysis; p < 0.05 was considered as statistically significant. Results: The mean IT was 31.5 ± 8.3 s in AWS group and 26.4 ± 8.9 seconds in ML group. Statistical significant difference was not found in IT between the two groups. The IT of AWS group was statistically related to extensive clefts. Airway complications were detected in ML group. Conclusion: AWS is useful for intubation of infants with CLP; it required IT similar to that required using ML, with a lower rate of airway complications. Trial Registration UMIN-CTR Registration number UMIN000024763 Registered 8 November 2016 Keywords: Airway Scope, Macintosh Laryngoscope, infant, intubation time


2018 ◽  
Vol 65 (4) ◽  
pp. 251-254
Author(s):  
Tomoka Matsumura ◽  
Chihiro Suzuki ◽  
Kazumasa Kubota ◽  
Shunsuke Minakuchi ◽  
Haruhisa Fukayama

We report a case of difficult nasal intubation utilizing a Pentax-Airway scope® AWS-100. A 4-month-old female with a rapidly growing melanotic neuroectodermal tumor was scheduled for resection under general anesthesia. The tumor was a large rubbery mass located in the middle of the mandible. For nasal intubation using the AWS, guidance of the tube toward the glottis was attempted using pediatric Magill forceps. Although we could hold the tube with the Magill forceps, it was difficult to insert the tube into the trachea due to the limited space in her hypopharynx. We then used a standard laryngoscope with a Miller straight blade for direct visual laryngoscopy and successfully intubated the patient with the aid of the pediatric Magill forceps. We often experience difficulty navigating a nasal endotracheal tube toward the glottis even when a clear glottic view is obtained with video laryngoscopes, especially in children with a small oropharyngeal space. However, some reports have been shown that video laryngoscopes are useful for intubation of the difficult airway and causes less stress to the upper airway than direct visual laryngoscopy. Video laryngoscopy can be an excellent way to provide nasal intubation in some but not all children.


Sign in / Sign up

Export Citation Format

Share Document