blood pumps
Recently Published Documents


TOTAL DOCUMENTS

520
(FIVE YEARS 66)

H-INDEX

34
(FIVE YEARS 4)

Author(s):  
Christopher Blum ◽  
Sascha Groß-Hardt ◽  
Ulrich Steinseifer ◽  
Michael Neidlin

Abstract Purpose Thrombosis ranks among the major complications in blood-carrying medical devices and a better understanding to influence the design related contribution to thrombosis is desirable. Over the past years many computational models of thrombosis have been developed. However, numerically cheap models able to predict localized thrombus risk in complex geometries are still lacking. The aim of the study was to develop and test a computationally efficient model for thrombus risk prediction in rotary blood pumps. Methods We used a two-stage approach to calculate thrombus risk. The first stage involves the computation of velocity and pressure fields by computational fluid dynamic simulations. At the second stage, platelet activation by mechanical and chemical stimuli was determined through species transport with an Eulerian approach. The model was compared with existing clinical data on thrombus deposition within the HeartMate II. Furthermore, an operating point and model parameter sensitivity analysis was performed. Results Our model shows good correlation (R2 > 0.93) with clinical data and identifies the bearing and outlet stator region of the HeartMate II as the location most prone to thrombus formation. The calculation of thrombus risk requires an additional 10–20 core hours of computation time. Conclusion The concentration of activated platelets can be used as a surrogate and computationally low-cost marker to determine potential risk regions of thrombus deposition in a blood pump. Relative comparisons of thrombus risk are possible even considering the intrinsic uncertainty in model parameters and operating conditions.


ASAIO Journal ◽  
2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Joshua Cysyk ◽  
Choon-Sik Jhun ◽  
Ray Newswanger ◽  
Walter Pae ◽  
Jenelle Izer ◽  
...  

2021 ◽  
pp. 37-39
Author(s):  
Pradeep Kumar Radhakrishnan ◽  
Sujatha Mohanty ◽  
Pulivarthi Nageshwar Rao ◽  
Sivakrishna Rao G V ◽  
Nagesh Kumar ◽  
...  

In recent years, the use of rotary blood pumps (RBPs) as continuous ow VADs has surged ahead, and virtually eliminated the use of pulsatile-ow or volume-displacement pumps for implantable, chronic mechanical circulatory support (MCS). Circuit Design modications like that in Saispandan has imparted pulsatility into RBP.Impeller designs are a signicant factor when designing centrifugal pumps as mechanical circulatory assist devices as smaller diameter impellers with higher rotational speeds to achieve target outputs would cause more blood component trauma compared to larger diameter impellers.Hydraulic performance and hemolysis tests in the same pump housing with different prototypes is needed. Ventricular assist parameters for efcient circulatory support would include an output of 5 L/min against 100 mmHg at speeds of 2500-3500 rpm. Vein height does not contribute signicantly to evaluation metric in most studies.


2021 ◽  
Author(s):  
Shelby A. Bieritz ◽  
P. Alex Smith ◽  
Yaxin Wang ◽  
William E. Cohn ◽  
Jane Grande-Allen

2021 ◽  
pp. 039139882110525
Author(s):  
Akiko Oota-Ishigaki ◽  
Takashi Yamane ◽  
Daisuke Sakota ◽  
Ryo Kosaka ◽  
Osamu Maruyama ◽  
...  

Low-flow blood pumps rated under 1 L/min are emerging for new medical applications, such as hemofiltration in acute use. In those pumps, platelet adhesion and aggregation have to be carefully considered because of clogging risk in the filter part. To find an acceptable hemocompatibility that can be applied to low-flow centrifugal blood pump design, the platelet aggregation index, clogging on a micromesh filter, and the hemolysis index were investigated using a low-flow blood pump designed for hemofiltration use. We conducted circulation testing in vitro using fresh porcine blood and two centrifugal pumps with different impeller inlet shapes. The Negative Log Platelet Aggregation Threshold Index (NL-PATI), which reflects the ability of residual platelets to aggregate, and flow rate were measured during reflux for 60 min, and the Normalized Index of Hemolysis (NIH (g/20 min)) was calculated. In addition, blood cell clogging after reflux was observed on the micromesh filter by SEM, and the adhesion rate was calculated. Our results showed that the platelet clogging on the micromesh filter occurred when the average NL-PATI was greater than 0.28 and the average NIH (g/20 min) was greater than 0.01. In contrast, platelet clogging on the micromesh was suppressed when NL-PATI was less than 0.17 and the NIH (g/20 min) was less than 0.003. These values might be used as acceptable hemocompatibility of low-flow centrifugal blood pumps with suppressed platelet clogging for hemofiltration pumps.


2021 ◽  
Vol 12 ◽  
Author(s):  
Peng Wu ◽  
Wenjing Xiang ◽  
Chengke Yin ◽  
Shu Li

In recent years, blood pumps have become the bridge to heart transplantation for patients with heart failure. Portability and wearability of blood pumps should be considered to ensure patient satisfaction in everyday life. To date, the focus has been on the development of portable and wearable peripheral components, little attention has been paid to the portable and wearable performance of the blood pump itself. This study reported a novel design of a wearable and portable extracorporeal centrifugal blood pump. Based on an in-house centrifugal maglev blood pump, the wearable and portable blood pump was designed with parallel inlet and outlet pipes to improve the wearable performance. A ring cavity was set at the inlet to convert the circumferential velocity of the inlet pipe to an axial velocity. The hydraulic and hemolytic performance of the baseline and portable blood pumps were analyzed and compared. Compared with the baseline pump, the hydrodynamic and hemolytic performance of the portable pump has been maintained without serious degradation. The results of this study will improve the life quality of patients with heart failure, and enhance the clinical benefits of artificial heart.


2021 ◽  
pp. 039139882110416
Author(s):  
Ge He ◽  
Jiafeng Zhang ◽  
Aakash Shah ◽  
Zachary B Berk ◽  
Lu Han ◽  
...  

Blood pumps have been increasingly used in mechanically assisted circulation for ventricular assistance and extracorporeal membrane oxygenation support or during cardiopulmonary bypass for cardiac surgery. However, there have always been common complications such as thrombosis, hemolysis, bleeding, and infection associated with current blood pumps in patients. The development of more biocompatible blood pumps still prevails during the past decades. As one of those newly developed pumps, the Breethe pump is a novel extracorporeal centrifugal blood pump with a hybrid magnetic and mechanical bearing with attempt to reduce device-induced blood trauma. To characterize the hydrodynamic and hemolytic performances of this novel pump and demonstrate its superior biocompatibility, we use a combined computational and experimental approach to compare the Breethe pump with the CentriMag and Rotaflow pumps in terms of flow features and hemolysis under an operating condition relevant to ECMO support (flow: 5 L/min, pressure head: ~350 mmHg). The computational results showed that the Breethe pump has a smaller area-averaged wall shear stress (WSS), a smaller volume with a scalar shear stress (SSS) level greater than 100 Pa and a lower device-generated hemolysis index compared to the CentriMag and Rotaflow pumps. The comparison of the calculated residence times among the three pumps indicated that the Breethe pump might have better washout. The experimental data from the in vitro hemolysis testing demonstrated that the Breethe pump has the lowest normalized hemolysis index (NIH) than the CentriMag and Rotaflow pumps. It can be concluded based on both the computational and experimental data that the Breethe pump is a viable pump for clinical use and it has better biocompatibility compared to the clinically accepted pumps.


2021 ◽  
pp. 039139882110416
Author(s):  
Jia-Dong Huo ◽  
Peng Wu ◽  
Liudi Zhang ◽  
Wei-Tao Wu

An accurate representation of the flow field in blood pumps is important for the design and optimization of blood pumps. The primary turbulence modeling methods applied to blood pumps have been the Reynolds-averaged Navier–Stokes (RANS) or URANS (unsteady RANS) method. Large eddy simulation (LES) method has been introduced to simulate blood pumps. Nonetheless, LES has not been widely used to assist in the design and optimization of blood pumps to date due to its formidable computational cost. The purpose of this study is to explore the potential of the LES technique as a fast and accurate engineering approach for the simulation of rotary blood pumps. The performance of “Light LES” (using the same time and spatial resolutions as the URANS) and LES in two rotary blood pumps was evaluated by comparing the results with the URANS and extensive experimental results. This study showed that the results of both “Light LES” and LES are superior to URANS, in terms of both performance curves and key flow features. URANS could not predict the flow separation and recirculation in diffusers for both pumps. In contrast, LES is superior to URANS in capturing these flows, performing well for both design and off-design conditions. The differences between the “Light LES” and LES results were relatively small. This study shows that with less computational cost than URANS, “Light LES” can be considered as a cost-effective engineering approach to assist in the design and optimization of rotary blood pumps.