reaction volumes
Recently Published Documents


TOTAL DOCUMENTS

89
(FIVE YEARS 12)

H-INDEX

16
(FIVE YEARS 2)

2022 ◽  
Author(s):  
Jason Nguyen ◽  
Rebecca Hickman ◽  
Tracy Lee ◽  
Natalie Prystajecky ◽  
John Tyson

This procedure provides instructions on how to prepare DNA libraries for whole genome sequencing on an Illumina MiSeq or NextSeq using Illumina’s DNA Prep Library Preparation Kit scaled to half reaction volumes with modifications to the post-PCR procedures; tagmentation stop buffer and associated washes are removed and libraries are pooled post PCR then a single size selection is performed. This protocol is used to sequence SARS-CoV-2 using the cDNA/PCR protocol: https://dx.doi.org/10.17504/protocols.io.b3viqn4e


2022 ◽  
Author(s):  
Jason Nguyen ◽  
Rebecca Hickman ◽  
Tracy Lee ◽  
Natalie Prystajecky ◽  
John Tyson

This procedure provides instructions on how to prepare DNA libraries for whole genome sequencing on an Illumina MiSeq or NextSeq using Illumina’s DNA Prep Library Preparation Kit scaled to half reaction volumes with modifications to the post-PCR procedures; tagmentation stop buffer and associated washes are removed and libraries are pooled post PCR then a single size selection is performed.


Diseases ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 84
Author(s):  
Sabine Bock ◽  
Bernd Hoffmann ◽  
Martin Beer ◽  
Kerstin Wernike

Since the beginning of 2020, the betacoronavirus SARS-CoV-2 is causing a global pandemic of an acute respiratory disease termed COVID-19. The diagnostics of the novel disease is primarily based on direct virus detection by RT-PCR; however, the availability of test kits may become a major bottleneck, when millions of tests are performed per week. To increase the flexibility of SARS-CoV-2 diagnostics, three real-time RT-PCR assays listed on the homepage of the World Health Organization were selected and investigated regarding their compatibility with three different RT-PCR kits. Furthermore, the reaction volume of the PCR chemistry was reduced up to half of the original protocol to make the individual reactions more cost- and resource-effective. When testing dilution series of culture-grown virus, nearly identical quantification cycle values (Cq) were obtained for all RT-PCR assay/chemistry combinations. Regarding the SARS-CoV-2 detection in clinical samples, agreeing results were obtained for all combinations for virus negative specimens and swabs containing high to medium viral genome loads. In cases of very low SARS-CoV-2 genome loads (Cq > 36), inconsistent results were observed, with some test runs scoring negative and some positive. However, no preference of a specific target within the viral genome (E, RdRp, or N) or of a certain chemistry was seen. In summary, a reduction of the reaction volume and the type of PCR chemistry did not influence the PCR sensitivity.


2021 ◽  
Author(s):  
Marc Fuchs ◽  
Clara Radulescu ◽  
Miao Tang ◽  
Arun Mahesh ◽  
Deborah Lavin ◽  
...  

Introduction: The COVID-19 pandemic has highlighted the importance of whole genome sequencing (WGS) of SARS-CoV-2 to inform public health policy. By enabling definition of lineages it facilitates tracking of the global spread of the virus. The evolution of new variants can be monitored and knowledge of specific mutations provides insights into the mechanisms through which the virus increases transmissibility or evades immunity. To date almost one million SARS-CoV-2 genomes have been sequenced by members of the COVID-19 Genomics UK (COG-UK) Consortium. To achieve similar feats in a more cost-effective and sustainable manner in future, improved high throughput virus sequencing protocols are required. We have therefore developed a miniaturized library preparation protocol with drastically reduced consumable use and costs. Methods: SARS-CoV-2 RNA was amplified using the ARTIC nCov-2019 multiplex RT-PCR protocol and purified using a conventional liquid handling system. Acoustic liquid transfer (Echo 525) was employed to reduce reaction volumes and the number of tips required for a Nextera XT library preparation. Sequencing was performed on an Illumina MiSeq. Results: We present the 'Mini-XT' miniaturized tagmentation-based library preparation protocol available on protocols.io (https://dx.doi.org/10.17504/protocols.io.bvntn5en). The final version of Mini-XT has been used to sequence 4,384 SARS-CoV-2 samples from N. Ireland with a COG-UK QC pass rate of 97.4%. Sequencing quality was comparable and lineage calling consistent for replicate samples processed with full volume Nextera DNA Flex (333 samples) or using nanopore technology (20 samples). SNP calling between Mini-XT and these technologies was consistent and sequences from replicate samples paired together in maximum likelihood phylogenetic trees. Conclusion: The Mini-XT protocol maintains sequence quality while reducing library preparation reagent volumes 8-fold and halving overall tip usage from sample to sequence to provide concomitant cost savings relative to standard protocols. This will enable more efficient high-throughput sequencing of SARS-CoV-2 isolates and future pathogen WGS.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Scott Sherrill-Mix ◽  
Young Hwang ◽  
Aoife M. Roche ◽  
Abigail Glascock ◽  
Susan R. Weiss ◽  
...  

Abstract Background Rapid spread of SARS-CoV-2 has led to a global pandemic, resulting in the need for rapid assays to allow diagnosis and prevention of transmission. Reverse transcription-polymerase chain reaction (RT-PCR) provides a gold standard assay for SARS-CoV-2 RNA, but instrument costs are high and supply chains are potentially fragile, motivating interest in additional assay methods. Reverse transcription and loop-mediated isothermal amplification (RT-LAMP) provides an alternative that uses orthogonal and often less expensive reagents without the need for thermocyclers. The presence of SARS-CoV-2 RNA is typically detected using dyes to report bulk amplification of DNA; however, a common artifact is nonspecific DNA amplification, which complicates detection. Results Here we describe the design and testing of molecular beacons, which allow sequence-specific detection of SARS-CoV-2 genomes with improved discrimination in simple reaction mixtures. To optimize beacons for RT-LAMP, multiple locked nucleic acid monomers were incorporated to elevate melting temperatures. We also show how beacons with different fluorescent labels can allow convenient multiplex detection of several amplicons in “single pot” reactions, including incorporation of a human RNA LAMP-BEAC assay to confirm sample integrity. Comparison of LAMP-BEAC and RT-qPCR on clinical saliva samples showed good concordance between assays. To facilitate implementation, we developed custom polymerases for LAMP-BEAC and inexpensive purification procedures, which also facilitates increasing sensitivity by increasing reaction volumes. Conclusions LAMP-BEAC thus provides an affordable and simple SARS-CoV-2 RNA assay suitable for population screening; implementation of the assay has allowed robust screening of thousands of saliva samples per week.


PLoS ONE ◽  
2021 ◽  
Vol 16 (4) ◽  
pp. e0243333
Author(s):  
Julien Fassy ◽  
Caroline Lacoux ◽  
Sylvie Leroy ◽  
Latifa Noussair ◽  
Sylvain Hubac ◽  
...  

The emergence and quick spread of SARS-CoV-2 has pointed at a low capacity response for testing large populations in many countries, in line of material, technical and staff limitations. The traditional RT-qPCR diagnostic test remains the reference method and is by far the most widely used test. These assays are limited to a few probe sets, require large sample PCR reaction volumes, along with an expensive and time-consuming RNA extraction step. Here we describe a quantitative nanofluidic assay that overcomes some of these shortcomings, based on the BiomarkTM instrument from Fluidigm. This system offers the possibility of performing 4608 qPCR end-points in a single run, equivalent to 192 clinical samples combined with 12 pairs of primers/probe sets in duplicate, thus allowing the monitoring of SARS-CoV-2 including the detection of specific SARS-CoV-2 variants, as well as the detection other pathogens and/or host cellular responses (virus receptors, response markers, microRNAs). The 10 nL-range volume of BiomarkTM reactions is compatible with sensitive and reproducible reactions that can be easily and cost-effectively adapted to various RT-qPCR configurations and sets of primers/probe. Finally, we also evaluated the use of inactivating lysis buffers composed of various detergents in the presence or absence of proteinase K to assess the compatibility of these buffers with a direct reverse transcription enzymatic step and we propose several protocols, bypassing the need for RNA purification. We advocate that the combined utilization of an optimized processing buffer and a high-throughput real-time PCR device would contribute to improve the turn-around-time to deliver the test results to patients and increase the SARS-CoV-2 testing capacities.


2021 ◽  
Vol 61 (1_suppl) ◽  
pp. 92-95
Author(s):  
Stefania Turrina ◽  
Domenico De Leo

The introduction of next generation sequencing (NGS; also known as massively parallel sequencing) technology in the field of forensic genetics has been welcomed by the scientific community, above all because it complements the weaknesses of capillary electrophoresis (CE) in the analysis of genetic markers, such as single nucleotide polymorphism (SNP) typing. However, one of the main obstacles to its adoption does not seem to be the cost of the instrumentation, but rather the cost of the NGS library preparation kits. With the aim of reducing the cost of library preparation without compromising the quality of the results, we tried to scale down reaction volumes for the first two polymerase chain reactions in the amplification and enrichment phases of the targeted loci of library preparation using the ForenSeq™ DNA Signature Prep kit. We used 1 µL templated DNA input to a concentration of 1 ng/µL, instead of the 5 µL at 0.2 ng/µL recommended by the manufacturer. Our findings indicate that reduction of the library preparation volume using the ForenSeq™ DNA Signature Prep kit did not interfere with the quality and reproducibility of the DNA profiles obtained and can help lower the overall cost of NGS.


2020 ◽  
Author(s):  
Julien Fassy ◽  
Caroline Lacoux ◽  
Sylvie Leroy ◽  
Latifa Noussair ◽  
Sylvain Hubac ◽  
...  

AbstractThe emergence and quick spread of SARS-CoV-2 has pointed at a low capacity response for testing large populations in many countries, in line of material, technical and staff limitations. The traditional RT-qPCR diagnostic test remains the reference method and is by far the most widely used test. These assays are limited to a couple of probe sets, require large sample PCR reaction volumes, along with an expensive and time-consuming RNA extraction steps. Here we describe a quantitative nanofluidic assay that overcomes some of these shortcomings, based on the Biomark instrument from Fluidigm. This system offers the possibility of performing 4608 qPCR end-points in a single run, equivalent to 192 clinical samples combined with 12 pairs of primers/probe sets in duplicate, thus allowing the monitoring in addition to SARS-CoV-2 probes of other pathogens and/or host cellular responses (virus receptors, response markers, microRNAs). Its 10 nL range volume is compatible with sensitive and reproducible reactions that can be easily and cost-effectively adapted to various RT-qPCR configurations and sets of primers/probe. Finally, we also evaluated the use of inactivating lysis buffers composed of various detergents in the presence or absence of proteinase K to assess the compatibility of these buffers with a direct reverse transcription enzymatic step and we propose several procedures, bypassing the need for RNA purification. We advocate that the combined utilization of an optimized processing buffer and a high-throughput real-time PCR device would contribute to improve the turn-around-time to deliver the test results to patients and increase the SARS-CoV-2 testing capacities.


2020 ◽  
Vol 2 (2) ◽  
pp. 164-171
Author(s):  
Hanan K. Mahmood ◽  
Nadia F. Salman ◽  
Dhurgham H. Hasan ◽  
Khaleefah M. Salih ◽  
Maryam A. Sadiq ◽  
...  

DNA amplification is known to be the most expensive step during forensic DNA analysis. This study evaluated the half-reaction amplification protocol (12.5 µL PCR product) using DNA amplification kits from Promega PowerPlex® (PowerPlex® 18D System, PowerPlex ®21System, PowerPlex® Fusion System and PowerPlex® Y23 System), which might aid in reducing sample analysis cost by half and allow the analysis of more samples. A sensitivity study (15 samples) along with testing of various blood stain samples (n=100) that were submitted to the Medico-Legal Directorate laboratory for DNA testing was accomplished to compare the DNA profiles resulting from half-reaction volume procedure to those with full-reaction volume procedure, using three differed methods along with standard protocol to evaluate the effect of half reaction volume with some variables. Results demonstrated the use of half-reaction amplification protocol preceded by washing step for all aforementioned DNA amplification kits gave a robust and reliable amplification result that aid to increase the number of samples analyzed and decreased the test cost for each kit without compromising the quality of 3DNA profiles obtained.


Author(s):  
Ghulam Destgeer ◽  
Mengxing Ouyang ◽  
Chueh-Yu Wu ◽  
Dino Di Carlo

Reactions performed in uniform microscale volumes have enabled numerous applications in the analysis of rare entities (e.g. cells and molecules), however, sophisticated instruments are usually required to form large numbers of uniform compartments. Here, uniform aqueous droplets are formed by simply mixing microscale multi-material particles, consisting of concentric hydrophobic outer and hydrophilic inner layers, with oil and water. The particles are manufactured in batch using a 3D printed device to co-flow four concentric streams of polymer precursors which are polymerized with UV light. The size of the particles is readily controlled by adjusting the fluid flow rate ratios and mask design; whereas the cross-sectional shapes are altered by microfluidic nozzle design in the 3D printed device. Once a particle encapsulates an aqueous volume, each “dropicle” provides uniform compartmentalization and customizable shape-coding for each sample volume to enable multiplexing of uniform reactions in a scalable manner. We implement an enzymatically-amplified affinity assay using the dropicle system, yielding a detection limit of <1 pM with a dynamic range of at least 3 orders of magnitude. Moreover, multiplexing using two types of shape-coded particles was demonstrated without cross talk, laying a foundation for democratized single-entity assays.


Sign in / Sign up

Export Citation Format

Share Document