intraocular lens power
Recently Published Documents


TOTAL DOCUMENTS

710
(FIVE YEARS 175)

H-INDEX

46
(FIVE YEARS 6)

2021 ◽  
pp. 112067212110655
Author(s):  
Alessandro Arrigo ◽  
Gianpiera Gambaro ◽  
Francesco Fasce ◽  
Emanuela Aragona ◽  
Innocente Figini ◽  
...  

Purpose This study aimed to analyze biometry values cutoffs for the choice of the best intraocular lens power calculation formula for AcrySof IQ Vivity intraocular lens. Methods The study was designed as interventional case series with 3 months of follow-up. Intraocular lens power calculation formulas included Barrett Universal II and SRK/T. The first was adopted for the intraocular lens power choice. The quantitative analysis focused on the identification of specific biometric cutoffs considering axial length, anterior chamber depth, and corneal powers. We included only the dominant eye in the statistical analysis. Results One hundred and eight eyes of 54 patients (23 males; mean age 62 ± 5 years) with no ocular diseases were included. Best-corrected visual acuity improved from 0.3 ± 0.2 to 0.0 ± 0.0 logMAR. All the eyes reached spectacles-free far and intermediate visions; a spherical addition of + 1.0D was necessary to adjust near vision. We identified significant quantitative cutoffs based on axial length and anterior chamber depth. Barrett Universal II resulted the best formula for eyes disclosing an axial length >25 mm, whereas SRK/T turned out to be the best choice for the eyes characterized by an anterior chamber depth <2.8 mm. Our analysis disclosed an overall sensitivity of 0.8 and a specificity of 0.7 ( p < 0.01). Conclusions Axial length and anterior chamber depth influence the choice of Barrett Universal II and SRK/T formulas. Quantitative biometric cutoffs may be useful to discriminate the best formula to be adopted.


2021 ◽  
pp. 112067212110655
Author(s):  
Joaquim Fernández-Rosés ◽  
José Lamarca ◽  
David P. Piñero ◽  
Rafael I. Barraquer

Purpose To compare the accuracy of Sirius ray tracing software with the Barrett Universal II formula for intraocular lens power prediction in virgin eyes. Methods Retrospective case series including 86 eyes that have undergone uneventful cataract surgery with SN60WF implantation. The median absolute error, mean prediction error, variance, and the percentage of eyes within ± 0.25 D, ± 0.50 D, ± 0.75 D, and ± 1.00 D of the prediction error in refraction were calculated. The correlation of prediction error with different baseline parameters was investigated. Results No differences were found between the median absolute error of the Barrett Universal II formula (0.226 D) and the ray tracing software with different intraocular lens centerings; apex (0.331 D), limbus (0.345 D), and pupil (0.342 D) ( p = 0.084). The variance, from lowest to highest, was the Barrett Universal II (0.144 D2), ray tracing-limbus (0.285 D2), ray tracing-pupil (0.285 D2), and ray tracing-apex (0.287 D2) ( p = 0.027). The Barrett Universal II formula showed a higher percentage of eyes within ± 0.25 D (56.98%), ± 0.50 D (82.56%), and ± 0.75 D (93.02%) compared to ray tracing software ( p < 0.01). A significant correlation between the prediction error of the Barrett Universal II formula and corneal diameter (r = 0.322, p = 0.002) and pupil diameter (r = 0.230, p = 0.033) was found. Also, a positive correlation between the prediction error of Sirius ray tracing and axial length ( p < 0.001) and pupil diameter ( p = 0.01) was found. Conclusion There is a trend of the Barrett Universal II formula to be more accurate than Sirius ray tracing software for intraocular lens power calculation in virgin eyes. This should be confirmed in future prospective comparative studies.


2021 ◽  
Vol 71 (5) ◽  
pp. 1828-32
Author(s):  
Aisha Rafique ◽  
Omar Zafar ◽  
Summaya Khan

Objective: To compare optical biometry and A-scan for calculating intraocular lens power in patients with nuclear cataract at tertiary care eye hospital. Study Design: Cross sectional comparative study. Place and Duration of Study: Armed Forces Institute of Ophthalmology, Pak Emirates Military Hospital, Rawalpindi, from Jul to Dec 2018. Methodology: In this study 70 eyes of 70 patients planned for cataract surgery by phacoemulsification underwent both optical biometry with intraocular lens master and ultrasound biometry applanation by A scan after informed consent. Intraocular lens power calculated by these two methods of biometry was compared. Phacoemulsification surgery was performed through a 2.3 mm superior temporal clear corneal incision. All patients underwent in the bag implantation of the same intraocular lens type. Results: The mean age of the patients was 62.89 ± 6.69 years. A significant (p-value<0.001) difference in intraocular lens power calculation was noted (20.96 ± 1.76 vs. 22.03 ± 1.61) with optical biometry and A-scan respectively. Association on the basis of age groups showed a significant (p-value<0.001) difference in both strata that was among patients having age ≤65 years and patients having age >65 years. Conclusion: Optical biometry was found efficient and safe method for calculation of intraocular lens power. Optical biometry is noncontact method having very less chance of infection and suitable for most of the eye types.