light reflectance
Recently Published Documents


TOTAL DOCUMENTS

264
(FIVE YEARS 53)

H-INDEX

28
(FIVE YEARS 3)

2022 ◽  
Vol 2 ◽  
Author(s):  
Tim Granata ◽  
Bernd Rattenbacher ◽  
Gernot John

Bioreactors in space have applications from basic science to microbial factories. Monitoring bioreactors in microgravity has challenges with respect to fluidics, aeration, sensor size, sample volume and disturbance of medium and cultures. We present a case study of the development of small bioreactors and a non-invasive method to monitor dissolved oxygen, pH, and biomass of yeast cultures. Two different bioreactor configurations were tested for system volumes of 60 ml and 10.5 ml. For both configurations, the PreSens SFR vario, an optical sensor array, collected data autonomously. Oxygen and pH in the cultures were monitored using chemically doped spots, 7 mm in diameter, that were fixed to the bottom of sampling chambers. Spots emitted a fluorescent signal for DO and pH when reacted with oxygen molecules and hydrogen ions, respectively. Biomass was sensed using light reflectance at centered at 605 nm. The, optical array had three light detectors, one for each variable, that returned signals that were pre- and post-calibrated. For heterotrophic cultures requiring oxygen and respiring carbon dioxide, a hollow fiber filter, in-line with the optical array, oxygenated cells and remove carbon dioxide. This provided oxygen levels that were sufficient to maintain aerobic respiration for steady state conditions. Time series of yeast metabolism in the two bioreactors are compared and discussed. The bioreactor configurations can be easily be modified for autotrophic cultures such that carbon dioxide is enhanced and oxygen removed, which would be required for photosynthetic algal cultures.


2021 ◽  
Vol 2021 (49) ◽  
pp. 37-44
Author(s):  
I. B. Ivasiv ◽  

It has been proposed to utilize the median algorithm for determination of the extrema positions of diffuse light reflectance intensity distribution by a discrete signal of a photodiode linear array. The algorithm formula has been deduced on the base of piecewise-linear interpolation for signal representation by cumulative function. It has been shown that this formula is much simpler for implementation than known centroid algorithm and the noise immune Blais and Rioux detector algorithm. Also, the methodical systematic errors for zero noise as well as the random errors for full common mode additive noises and uncorrelated noises have been estimated and compared for mentioned algorithms. In these terms, the proposed median algorithm is proportionate to Blais and Rioux algorithm and considerably better then centroid algorithm.


Oral Oncology ◽  
2021 ◽  
Vol 123 ◽  
pp. 105627
Author(s):  
Oisín Bugter ◽  
Yassine Aaboubout ◽  
Mahesh Algoe ◽  
Henriëtte S. de Bruijn ◽  
Stijn Keereweer ◽  
...  

2021 ◽  
Author(s):  
Smriti Baruah ◽  
Janmoni Borah ◽  
Joyatri Bora ◽  
Santanu Maity

Abstract Proficiency in light reflectance mitigation is the most crucial factor for high photodetector performance. In this respect light trapping mechanism based on nanostructures or microstructures such as nanopillars, nanocones, nanopyramids have emerged as the most promising candidate for reducing overall light reflectance. This could be attributed to its effective large irradiation area, multiple scattering of incident light as well as increased path length of incident rays in these nanostructures. This paper proposes an optical modelling of a GaAs/GaSb material based vertically oriented core-shell cone topped octagonal shaped nanopillar structure with periodical trapezoidal nanotexturization over it to be deployed over a circular planar detector’s surface of radius 50um. The geometrical analytical investigation of the proposed model exhibits a 0.999 overall absorbance and 0.995A/W photoresponsivity along with 87% EQE at 1um operating wavelength.


Author(s):  
Andrzej Molak ◽  
Anna Z. Szeremeta ◽  
Janusz Koperski

This work shows a correlation between light reflectance, absorption, and morphologies of series of (1-x) BM–x PT, (x = 0.0, 0.02, 0.04, 0.08, 0.12, 0.16, 0.24) ceramics composite. The (1-x) BM–x PT showed features of a black mirror with a low optical energy gap. The measured Vis-NIR diffused reflectance enabled the calculation of the energy gap using the modified Kubelka-Munk function. The estimated energy gap was lower than 1.5 eV related to low reflectance in the Vis-NIR range. Moreover, obtained histograms of grains, using scanning electron microscope, enabled the correlation between grains size and amount of lead titanate. We deduced from the ceramics surface morphology that marked porosity also induced reflectivity of low magnitude. We correlated the magnitude of the energy gap with phases of the BM-PT composite and with the electrical conductivity activation energy reported in the literature. Our results findings opened prospect studied materials for optical applications.


Biosensors ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 268
Author(s):  
Dimitra Tsounidi ◽  
Georgios Koukouvinos ◽  
Vasilios Christianidis ◽  
Evangelia Legaki ◽  
Vasiliki Giogli ◽  
...  

The development of methods and miniaturized systems for fast and reliable quantitative determinations at the Point-of-Care is a top challenge and priority in diagnostics. In this work, a compact bench-top system, based on White Light Reflectance Spectroscopy, is introduced and evaluated in an application with high clinical interest, namely the determination of C-Reactive protein (CRP) in human blood samples. The system encompassed all the necessary electronic and optical components for the performance of the assay, while the dedicated software provided the sequence and duration of assay steps, the reagents flow rate, the real-time monitoring of sensor response, and data processing to deliver in short time and accurately the CPR concentration in the sample. The CRP assay included two steps, the first comprising the binding of sample CRP onto the chip immobilized capture antibody and the second the reaction of the surface immunosorbed CRP molecules with the detection antibody. The assay duration was 12 min and the dynamic range was from 0.05 to 200 μg/mL, covering both normal values and acute inflammation incidents. There was an excellent agreement between CRP values determined in human plasma samples using the developed device with those received for the same samples by a standard diagnostic laboratory method.


Biology ◽  
2021 ◽  
Vol 10 (5) ◽  
pp. 445
Author(s):  
Roshani S. Acharya ◽  
Timothy Leslie ◽  
Emily Fitting ◽  
Joan Burke ◽  
Kelly Loftin ◽  
...  

The decline in insect pollinators has increased the importance of accurately monitoring pollinator diversity and abundance over time. Sampling techniques include the use of passive insect traps such as pan traps, yet there is still discussion over their utility and effectiveness in different ecosystems. The objective was to examine four different colors of pan traps (blue, green, yellow, and purple) for their utility in sampling bees in native forages rotationally grazed by sheep and to compare the relative abundance, richness, similarity, and community assemblage patterns among the four trap colors. Most bees were from the Halictidae family (89%). The most abundant species were Lasioglossum imitatum (42.2%), Augochlorella aurata (8.3%), L. subviridatum (6.8), Agapostemon texanus (6.4), and L. birkmani (4.1%). Blue color traps exhibited the highest rates of bee capture and species accumulation. Purple and yellow colored traps were moderately effective in capturing bees, while the green color pan traps were least effective. Similarly, observed and extrapolated species richness was highest in blue trap, followed by purple, yellow, and green. Notably, the blue trap captured the highest number of unique species, followed by purple, yellow and green traps. Considering the total number of insects collected (including bees and other insects), yellow and green traps captured a significantly higher number of insects than other colored traps. The light reflectance from blue, purple, green and yellow pan traps had peaks at ~450, 400, 550, and 600 nm, respectively. Since different insects respond to different light intensities, wavelengths, and reflectivity, these results could be used to guide future trapping protocols targeting certain insect groups in livestock pasture and similar ecosystems.


Biosensors ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 153
Author(s):  
Georgios Koukouvinos ◽  
Chrysoula-Evangelia Karachaliou ◽  
Ioannis Raptis ◽  
Panagiota Petrou ◽  
Evangelia Livaniou ◽  
...  

Carbendazim is a systemic benzimidazole-type fungicide with broad-spectrum activity against fungi that undermine food products safety and quality. Despite its effectiveness, carbendazim constitutes a major environmental pollutant, being hazardous to both humans and animals. Therefore, fast and reliable determination of carbendazim levels in water, soil, and food samples is of high importance for both food industry and public health. Herein, an optical biosensor based on white light reflectance spectroscopy (WLRS) for fast and sensitive determination of carbendazim in fruit juices is presented. The transducer is a Si/SiO2 chip functionalized with a benzimidazole conjugate, and determination is based on a competitive immunoassay format. Thus, for the assay, a mixture of an in-house developed rabbit polyclonal anti-carbendazim antibody with the standards or samples is pumped over the chip, followed by biotinylated secondary antibody and streptavidin. The WLRS platform allows for real-time monitoring of biomolecular interactions carried out onto the Si/SiO2 chip by transforming the shift in the reflected interference spectrum caused by the immunoreaction to effective biomolecular adlayer thickness. The sensor is able to detect 20 ng/mL of carbendazim in fruit juices with high accuracy and precision (intra- and inter-assay CVs ≤ 6.9% and ≤9.4%, respectively) in less than 30 min, applying a simple sample treatment that alleviates any “matrix-effect” on the assay results and a 60 min preincubation step for improving assay sensitivity. Excellent analytical characteristics and short analysis time along with its small size render the proposed WLRS immunosensor ideal for future on-the-spot determination of carbendazim in food and environmental samples.


2021 ◽  
Author(s):  
Joel Kuttruff ◽  
Roman Krahne ◽  
Antonio de Luca ◽  
Vincenzo Caligiuri ◽  
Nicolò Maccaferri

Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2683
Author(s):  
Michailia Angelopoulou ◽  
Konstantina Tzialla ◽  
Angeliki Voulgari ◽  
Mary Dikeoulia ◽  
Ioannis Raptis ◽  
...  

Biosensors represent an attractive approach for fast bacteria detection. Here, we present an optical biosensor for the detection of Salmonella typhimurium lipopolysaccharide (LPS) and Salmonella bacteria in drinking water, based on white light reflectance spectroscopy. The sensor chip consisted of a Si die with a thin SiO2 layer on top that was transformed into a biosensor through the immobilization of Salmonella LPS. The optical setup included a reflection probe with seven 200 μm fibers, a visible and near-infrared light source, and a spectrometer. The six fibers at the reflection probe circumference were coupled with the light source and illuminated the biosensor chip vertically, whereas the central fiber collected the reflected light and guided it to the spectrometer. A competitive immunoassay configuration was adopted for the analysis. Accordingly, a mixture of LPS or bacteria solution, pre-incubated for 15 min, with an anti-Salmonella LPS antibody was pumped over the chip followed by biotinylated secondary antibody and streptavidin for signal enhancement. The binding of the free anti-Salmonella antibody to chip-immobilized LPS led to a shift of the reflectance spectrum that was inversely related to the analyte concentration (LPS or bacteria) in the calibrators or samples. The total assay duration was 15 min, and the detection limits achieved were 4 ng/mL for LPS and 320 CFU/mL for bacteria. Taking into account the low detection limits, the short analysis time, and the small size of the chip and instrumentation employed, the proposed immunosensor could find wide application for bacteria detection in drinking water.


Sign in / Sign up

Export Citation Format

Share Document