respiratory gating
Recently Published Documents


TOTAL DOCUMENTS

415
(FIVE YEARS 58)

H-INDEX

40
(FIVE YEARS 2)

Author(s):  
Bruno Madore ◽  
Gabriela Belsley ◽  
Cheng-Chieh Cheng ◽  
Frank Preiswerk ◽  
Marie Foley Kijewski ◽  
...  

Abstract Breathing motion can displace internal organs by up to several cm; as such, it is a primary factor limiting image quality in medical imaging. Motion can also complicate matters when trying to fuse images from different modalities, acquired at different locations and/or on different days. Currently available devices for monitoring breathing motion often do so indirectly, by detecting changes in the outline of the torso rather than the internal motion itself, and these devices are often fixed to floors, ceilings or walls, and thus cannot accompany patients from one location to another. We have developed small ultrasound-based sensors, referred to as ‘organ configuration motion’ (OCM) sensors, that attach to the skin and provide rich motion-sensitive information. In the present work we tested the ability of OCM sensors to enable respiratory gating during in vivo PET imaging. A motion phantom involving an FDG solution was assembled, and two cancer patients scheduled for a clinical PET/CT exam were recruited for this study. OCM signals were used to help reconstruct phantom and in vivo data into time series of motion-resolved images. As expected, the motion-resolved images captured the underlying motion. In Patient #1, a single large lesion proved to be mostly stationary through the breathing cycle. However, in Patient #2, several small lesions were mobile during breathing, and our proposed new approach captured their breathing-related displacements. In summary, a relatively inexpensive hardware solution was developed here for respiration monitoring. Because the proposed sensors attach to the skin, as opposed to walls or ceilings, they can accompany patients from one procedure to the next, potentially allowing data gathered in different places and at different times to be combined and compared in ways that account for breathing motion.


2021 ◽  
pp. 13-20
Author(s):  
April-Louise Smith ◽  
Richard Manber
Keyword(s):  

Cancers ◽  
2021 ◽  
Vol 13 (20) ◽  
pp. 5092
Author(s):  
Kim Melanie Kraus ◽  
Cristoforo Simonetto ◽  
Pavel Kundrát ◽  
Vanessa Waitz ◽  
Kai Joachim Borm ◽  
...  

We investigated the potential of respiratory gating to mitigate the motion-caused misdosage in lung stereotactic body radiotherapy (SBRT). For fourteen patients with lung tumors, we investigated treatment plans for a gating window (GW) including three breathing phases around the maximum exhalation phase, GW40-60. For a subset of six patients, we also assessed a preceding three-phase GW20-40 and six-phase GW20-70. We analyzed the target volume, lung, esophagus, and heart doses. Using normal tissue complication probability (NTCP) models, we estimated radiation pneumonitis and esophagitis risks . Compared to plans without gating, GW40-60 significantly reduced doses to organs at risk without impairing the tumor doses. On average, the mean lung dose decreased by 0.6 Gy (p < 0.001), treated lung V20Gy by 2.4% (p = 0.003), esophageal dose to 5cc by 2.0 Gy (p = 0.003), and maximum heart dose by 3.2 Gy (p = 0.009). The model-estimated mean risks of 11% for pneumonitis and 12% for esophagitis without gating decreased upon GW40-60 to 7% and 9%, respectively. For the highest-risk patient, gating reduced the pneumonitis risk from 43% to 32%. Gating is most beneficial for patients with high-toxicity risks. Pre-treatment toxicity risk assessment may help optimize patient selection for gating, as well as GW selection for individual patients.


2021 ◽  
pp. 20201350
Author(s):  
Michael Messerli ◽  
Virginia Liberini ◽  
Hannes Grünig ◽  
Alexander Maurer ◽  
Stephan Skawran ◽  
...  

Objectives: To evaluate the impact of fully automatic motion correction by data-driven respiratory gating (DDG) on positron emission tomography (PET) image quality, lesion detection and patient management. Materials and Methods: A total of 149 patients undergoing PET/CT for cancer (re-)staging were retrospectively included. Patients underwent a PET/CT on a digital detector scanner and for every patient a PET data set where DDG was enabled (PETDDG) and as well as where DDG was not enabled (PETnonDDG) was reconstructed. All PET data sets were evaluated by two readers which rated the general image quality, motion effects and organ contours. Further, both readers reviewed all scans on a case-by-case basis and evaluated the impact of PETDDG on additional apparent lesion, change of report, and change of management. Results: In 85% (n = 126) of the patients, at least one bed position was acquired using DDG, resulting in mean scan time increase of 4:37 min per patient in the whole study cohort (n = 149). General image quality was not rated differently for PETnonDDG and PETDDG images (p = 1.000) while motion effects (i.e. indicating general blurring) was rated significantly lower in PETDDG images and organ contours, including liver and spleen, were rated significantly sharper using PETDDG as compared to PETnonDDG (all p < 0.001). In 27% of patients, PETDDG resulted in a change of the report and in a total of 12 cases (8%), PETDDG resulted in a change of further clinical management. Conclusion: Deviceless DDG provided reliable fully automatic motion correction in clinical routine and increased lesion detectability and changed management in a considerable number of patients. Advances in knowledge: DDG enables PET/CT with respiratory gating to be used routinely in clinical practice without external gating equipment needed.


Sensors ◽  
2021 ◽  
Vol 21 (16) ◽  
pp. 5525
Author(s):  
Qi Zhan ◽  
Wenjin Wang ◽  
Xiaorong Ding

To control the spread of coronavirus disease 2019 (COVID-19), it is effective to perform a fast screening of the respiratory rate of the subject at the gate before entering a space to assess the potential risks. In this paper, we examine the potential of a novel yet cost-effective solution, called thermopile-based respiratory gating, to contactlessly screen a subject by measuring their respiratory rate in the scenario with an entrance gate. Based on a customized thermopile array system, we investigate different image and signal processing methods that measure respiratory rate from low-resolution thermal videos, where an automatic region-of-interest selection-based approach obtains a mean absolute error (MAE) of 0.8 breaths per minute. We show the feasibility of thermopile-based respiratory gating and quantify its limitations and boundary conditions in a benchmark (e.g., appearance of face mask, measurement distance and screening time). The technical validation provided by this study is helpful for designing and implementing a respiratory gating solution toward the prevention of the spread of COVID-19 during the pandemic.


Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S150
Author(s):  
Gordon Ho ◽  
Todd Atwood ◽  
Andrew Bruggeman ◽  
Kevin Moore ◽  
Elliot McVeigh ◽  
...  

PLoS ONE ◽  
2021 ◽  
Vol 16 (7) ◽  
pp. e0254758
Author(s):  
Naoharu Kobayashi

Respiratory motion management is crucial for high-resolution MRI of the heart, lung, liver and kidney. In this article, respiration guide using acoustic sound generated by pulsed gradient waveforms was introduced in the pulmonary ultrashort echo time (UTE) sequence and validated by comparing with retrospective respiratory gating techniques. The validated sound-guided respiration was implemented in non-contrast enhanced renal angiography. In the sound-guided respiration, breathe−in and–out instruction sounds were generated with sinusoidal gradient waveforms with two different frequencies (602 and 321 Hz). Performance of the sound-guided respiration was evaluated by measuring sharpness of the lung-liver interface with a 10–90% rise distance, w10-90, and compared with three respiratory motion managements in a free-breathing UTE scan: without respiratory gating (w/o gating), 0-dimensional k-space navigator (k-point navigator), and image-based self-gating (Img-SG). The sound-guided respiration was implemented in stack-of-stars balanced steady-state free precession with inversion recovery preparation for renal angiography. No subjects reported any discomfort or inconvenience with the sound-guided respiration in pulmonary or renal MRI scans. The lung-liver interface of the UTE images for sound-guided respiration (w10-90 = 6.99 ± 2.90 mm), k-point navigator (8.51 ± 2.71 mm), and Img-SG (7.01 ± 2.06 mm) was significantly sharper than that for w/o gating (17.13 ± 2.91 mm; p < 0.0001 for all of sound-guided respiration, k-point navigator and Img-SG). Sharpness of the lung-liver interface was comparable between sound-guided respiration and Img-SG (p = 0.99), but sound-guided respiration achieved better visualization of pulmonary vasculature. Renal angiography with the sound-guided respiration clearly delineated renal, segmental and interlobar arteries. In conclusion, the gradient sound guided respiration can facilitate a consistent diaphragm position in every breath and achieve performance of respiratory motion management comparable to image-based self-gating.


Author(s):  
D. Hubers ◽  
E. B. van Dieren ◽  
D. P. Woutersen ◽  
C. H. Slump

Abstract Aim: This study aims to compare the gating signals of patients with lung cancer recorded during the planning computed tomography scan with the ones recorded during treatment fractions. The results provide insights into how representative the respiratory signals from the planning scan are for radiation dose partitioning. Materials and methods: The amplitude and frequency of the respiratory signals of 29 patients with lung carcinoma were analysed and compared with the amplitude and frequency of those recorded during their planning scans. Moreover, a cross-correlation analysis was performed between the difference between the planning scan and fractions and features from the planning scan. Results: Two patients showed significantly different amplitude and frequency during treatment fractions compared to those from the planning scan. These patients showed low variances in frequency and amplitude during the different fractions. The difference between planning scan and fractions is correlated with the variances within the planning scan. Findings: Respiratory signals can differ between the planning scan and the fractions. In this case, a new planning scan may be beneficial. The respiratory signals from the planning scan may be predictive of whether the planning scan will be representative and usable as a control measure during radiotherapy fractions.


Author(s):  
Jian-Kuen Wu ◽  
Shih-Han Chen ◽  
Feng-Ming Hsu ◽  
Shu-Hsien Liao ◽  
Yu-Jen Wang