orthodontic implants
Recently Published Documents


TOTAL DOCUMENTS

38
(FIVE YEARS 12)

H-INDEX

6
(FIVE YEARS 1)

2022 ◽  
Vol 9 (1) ◽  
pp. 12
Author(s):  
Dmitriy Suetenkov ◽  
Dmitriy Ivanov ◽  
Aleksandr Dol ◽  
Ekaterina Diachkova ◽  
Yuriy Vasil’ev ◽  
...  

Orthodontic implants have been developed for the implementation of skeletal anchorage and are effectively used in the design of individual orthodontic devices. However, despite a significant amount of clinical research, the biomechanical aspects of the use of skeletal anchorage have not been adequately studied. The aim of this work was to numerically investigate the stress–strain state of the developed palatal orthodontic device supported by mini-implants. Four possible options for the placement of mini-implants in the bone were analyzed. The effect of a chewing load of 100 N on the bite plane was investigated. The study was carried out using biomechanical modeling based on the finite element method. The installation of the palatal orthodontic device fixed on mini-implants with an individual bite plane positioned on was simulated. The dependence of equivalent stresses and deformation changes on the number and location of the supporting mini-implants of the palatal orthodontic device was investigated. Two materials (titanium alloy and stainless steel) of the palatal orthodontic device were also investigated. The choice of a successful treatment option was based on the developed biomechanical criteria for assessing the surgical treatment success. Application of the criteria made it possible to estimate the stability and strength of fixation of each of the considered mini-implants installation options. As a result, options for the mini-implants optimal placement were identified (the first and the fourth which provide distributed front and side support of the device), as well as the preferred material (titanium alloy) for the manufacture of the palatal orthodontic device.


2021 ◽  
Author(s):  
Abdulqadir Rampurawala ◽  
Amol Patil

Orthodontic miniscrews have had a considerable impact on modern orthodontic treatment, not only by providing a new source of anchors for anchorage-demanding cases, but also for force management and control. Whilst miniscrews need to be mechanically stable during treatment to provide sufficient anchorage and predictable force control, as temporary anchorage devices they need also be easy to remove after orthodontic treatment. These requirements differentiate orthodontic miniscrews from dental implants - which once placed, are not to be removed - and dictate the approach as to how their clinical performance can be optimized. Over the past decade, various titanium surface modifications and improvements in implant surface topography have shown to enhance osseointegration of endosseous dental implants. Some of these techniques have helped provide a similar enhancement of the biomechanical potential of orthodontic miniscrews as well. In this perspective, we present a brief discussion on all such reported techniques followed by a detailed account of the most recently proposed ultraviolet photofunctionalization technique - a novel chair-side surface modification method.


Author(s):  
Mira Hüfner ◽  
Nicole Rauch ◽  
Beryl Schwarz‐Herzke ◽  
Ivonne Jeanette Knorr ◽  
Martin Sager ◽  
...  

2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Kashif Ishfaq ◽  
Mudassar Rehman ◽  
Ahmed Raza Khan ◽  
Yanen Wang

Purpose Human aging is becoming a common issue these days as it results in orthopaedic-related issues such as joints disorderness, bone-fracture. People with age = 60 years suffer more from these aforesaid issues. It is expected that these issues in human beings will ultimately reach 2.1 billion by 2050 worldwide. Furthermore, the increase in traffic accidents in young people throughout the world has significantly emerged the need for artificial implants. Their implantation can act as a substitute for fractured bones or disordered joints. Therefore, this study aims to focus on electron beam melted titanium (Ti)-based orthopaedic implants along with their recent trends in the field. Design/methodology/approach The main contents of this work include the basic theme and background of the metal-based additive manufacturing, different implant materials specifically Ti alloys and their classification based on crystallographic transus temperature (including α, metastable β, β and α + β phases), details of electron beam melting (EBM) concerning its process physics, various control variables and performance characteristics of EBMed Ti alloys in orthopaedic and orthodontic implants, applications of EBMed Ti alloys in various load-bearing implants, different challenges associated with the EBMed Ti-based implants along with their possible solutions. Recent trends and shortfalls have also been described at the end. Findings EBM is getting significant attention in medical implants because of its minor issues as compared to conventional fabrication practices such as Ti casting and possesses a significant research potential to fabricate various medical implants. The elastic modulus and strength of EBMed ß Ti-alloys such as 24Nb-4Zr-8Sn and Ti-33Nb-4Sn are superior compared to conventional Ti for orthopaedic implants. Beta Ti alloys processed by EBM have near bone elastic modulus (approximately 35–50 GPa) along with improved tribo-mechanical performance involving mechanical strength, wear and corrosion resistance, along with biocompatibility for implants. Originality/value Advances in EBM have opened the gateway Ti alloys in the biomedical field explicitly ß-alloys because of their unique biocompatibility, bioactivity along with improved tribo-mechanical performance. Less significant work is available on the EBM of Ti alloys in orthopaedic and orthodontic implants. This study is directed solely on the EBM of medical Ti alloys in medical sectors to explore their different aspects for future research opportunities.


Author(s):  
Carlos Nelson Elias ◽  
Antônio Carlos de Oliveira Ruellas ◽  
Daniel Jogaib Fernandes

Materials ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 5690
Author(s):  
Camelia A. Szuhanek ◽  
Claudia G. Watz ◽  
Ștefana Avram ◽  
Elena-Alina Moacă ◽  
Ciprian V. Mihali ◽  
...  

Selecting the most biocompatible orthodontic implant available on the market may be a major challenge, given the wide array of orthodontic devices currently available on the market. The latest scientific data have suggested that in vitro evaluations using oral cell lines provide reliable data regarding the toxicity of residual particles released by different types of orthodontic devices. In this regard, the in vitro biocompatibility of three different commercially available implants (stainless steel and titanium-based implants) was assessed. Methods: As an in vitro model, human gingival fibroblasts (HGFs) were employed to evaluate the cellular morphology, cell viability, and cytotoxicity by means of 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) and lactate dehydrogenase (LDH) assays at 24 h and 72 h post-exposure to test implants. Results: The results correlate the composition and topography of the implant surface with biological experimental evaluations related to directly affected cells (gingival fibroblasts) and toxicological results on blood vessels (hen’s egg test-chorioallantoic membrane (HET-CAM) assay). The stainless steel implant exhibits a relative cytotoxicity against HGF cells, while the other two samples induced no significant alterations of HGF cells. Conclusion: Among the three test orthodontic implants, the stainless steel implant induced slight cytotoxic effects, thus increased vigilance is required in their clinical use, especially in patients with high sensitivity to nickel.


Odontology ◽  
2019 ◽  
Vol 108 (3) ◽  
pp. 503-510
Author(s):  
Yu-Chuan Tseng ◽  
Chia-Chun Tsai ◽  
Jung-Hsuan Cheng ◽  
Szu-Ting Chou ◽  
Chin-Yun Pan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document