breast magnetic resonance
Recently Published Documents


TOTAL DOCUMENTS

407
(FIVE YEARS 67)

H-INDEX

33
(FIVE YEARS 4)

Author(s):  
Janice Hui Ling Goh ◽  
Toh Leong Tan ◽  
Suraya Aziz ◽  
Iqbal Hussain Rizuana

Digital breast tomosynthesis (DBT) is a fairly recent breast imaging technique invented to overcome the challenges of overlapping breast tissue. Ultrasonography (USG) was used as a complementary tool to DBT for the purpose of this study. Nonetheless, breast magnetic resonance imaging (MRI) remains the most sensitive tool to detect breast lesion. The purpose of this study was to evaluate diagnostic performance of DBT, with and without USG, versus breast MRI in correlation to histopathological examination (HPE). This was a retrospective study in a university hospital over a duration of 24 months. Findings were acquired from a formal report and were correlated with HPE. The sensitivity of DBT with or without USG was lower than MRI. However, the accuracy, specificity and PPV were raised with the aid of USG to equivalent or better than MRI. These three modalities showed statistically significant in correlation with HPE (p < 0.005, chi-squared). Generally, DBT alone has lower sensitivity as compared to MRI. However, it is reassuring that DBT + USG could significantly improve diagnostic performance to that comparable to MRI. In conclusion, results of this study are vital to centers which do not have MRI, as complementary ultrasound can accentuate diagnostic performance of DBT.


2022 ◽  
Author(s):  
Youssef Chahid ◽  
Hein J. Verberne ◽  
Edwin Poel ◽  
N. Harry Hendrikse ◽  
Jan Booij

Abstract Background: Accurate sentinel lymph node (SLN) staging is essential for both prognosis and treatment in patients with breast cancer. However, the preoperative lymphoscintigraphy may fail to visualize the SLN. The aim of this retrospective study was to investigate whether parameters derived from anatomical breast imaging can predict SLN nonvisualization on lymphoscintigraphy. For this single-center retrospective study all data of mammography, breast magnetic resonance imaging (MRI), and lymphoscintigraphy of SLN procedures from January 2016 to April 2021 were collected and reviewed from the Amsterdam UMC electronic health records database.Results: A total of 758 breast cancer patients were included in this study. The SLN nonvisualization rate was 29.7% on lymphoscintigraphy. Multivariable analysis showed that age ≥ 70 years (P = 0.019; OR: 1.82; 95% CI: 1.10–3.01), BMI ≥ 30 kg/m2 (P = 0.031; OR: 1.59; 95% CI: 1.04–2.43), and nonpalpable tumors (P = 0.034; OR: 1.54; 95% CI: 1.03–2.04) were independent predictors of SLN nonvisualization. Differences in tumor size, Breast Imaging-Reporting and Data System (BI-RADS) classification, or breast density were not significantly associated with SLN nonvisualization.Conclusions: This study shows that, by using a multivariable analysis, risk factors for SLN nonvisualization in breast cancer patients during preoperative lymphoscintigraphy are age ≥70 years, BMI ≥30 kg/m2, and nonpalpable tumors. Parameters derived from mammography or breast MRI, however, are not useful to predict SLN nonvisualization on lymphoscintigraphy.


Cancers ◽  
2021 ◽  
Vol 14 (1) ◽  
pp. 159
Author(s):  
Susana I. S. Patuleia ◽  
Karijn P. M. Suijkerbuijk ◽  
Elsken van der Wall ◽  
Paul J. van Diest ◽  
Cathy B. Moelans

Nipple aspirate fluid (NAF) is an intraductal mammary fluid that, because of its close proximity to and origin from the tissue from which breast cancer originates, is a promising source of biomarkers for early breast cancer detection. NAF can be non-invasively acquired via the nipple by aspiration using a suction device; using oxytocin nasal spray helps increase yield and tolerability. The aspiration procedure is generally experienced as more tolerable than the currently used breast imaging techniques mammography and breast magnetic resonance imaging. Future applications of NAF-derived biomarkers include their use as a tool in the detection of breast carcinogenesis at its earliest stage (before a tumor mass can be seen by imaging), or as a supporting diagnostic tool for imaging, such as when imaging is less reliable (to rule out false positives from imaging) or when imaging is not advisable (such as during pregnancy and breastfeeding). Ongoing clinical studies using NAF samples will likely shed light on NAF’s content and clinical potential. Here, we present a narrative review and perspectives of NAF research at a glance.


2021 ◽  
Vol 1 ◽  
Author(s):  
David E. Frankhouser ◽  
Eric Dietze ◽  
Ashish Mahabal ◽  
Victoria L. Seewaldt

Angiogenesis is a key step in the initiation and progression of an invasive breast cancer. High microvessel density by morphological characterization predicts metastasis and poor survival in women with invasive breast cancers. However, morphologic characterization is subject to variability and only can evaluate a limited portion of an invasive breast cancer. Consequently, breast Magnetic Resonance Imaging (MRI) is currently being evaluated to assess vascularity. Recently, through the new field of radiomics, dynamic contrast enhanced (DCE)-MRI is being used to evaluate vascular density, vascular morphology, and detection of aggressive breast cancer biology. While DCE-MRI is a highly sensitive tool, there are specific features that limit computational evaluation of blood vessels. These include (1) DCE-MRI evaluates gadolinium contrast and does not directly evaluate biology, (2) the resolution of DCE-MRI is insufficient for imaging small blood vessels, and (3) DCE-MRI images are very difficult to co-register. Here we review computational approaches for detection and analysis of blood vessels in DCE-MRI images and present some of the strategies we have developed for co-registry of DCE-MRI images and early detection of vascularization.


2021 ◽  
pp. 1127-1133
Author(s):  
Mohamed El Beheiry ◽  
Thomas Gaillard ◽  
Noémie Girard ◽  
Lauren Darrigues ◽  
Marie Osdoit ◽  
...  

PURPOSE The treatment of breast cancer, the leading cause of cancer and cancer mortality among women worldwide, is mainly on the basis of surgery. In this study, we describe the use of a medical image visualization tool on the basis of virtual reality (VR), entitled DIVA, in the context of breast cancer tumor localization among surgeons. The aim of this study was to evaluate the speed and accuracy of surgeons using DIVA for medical image analysis of breast magnetic resonance image (MRI) scans relative to standard image slice-based visualization tools. MATERIALS AND METHODS In our study, residents and practicing surgeons used two breast MRI reading modalities: the common slice-based radiology interface and the DIVA system in its VR mode. Metrics measured were compared in relation to postoperative anatomical-pathologic reports. RESULTS Eighteen breast surgeons from the Institut Curie performed all the analysis presented. The MRI analysis time was significantly lower with the DIVA system than with the slice-based visualization for residents, practitioners, and subsequently the entire group ( P < .001). The accuracy of determination of which breast contained the lesion significantly increased with DIVA for residents ( P = .003) and practitioners ( P = .04). There was little difference between the DIVA and slice-based visualization for the determination of the number of lesions. The accuracy of quadrant determination was significantly improved by DIVA for practicing surgeons ( P = .01) but not significantly for residents ( P = .49). CONCLUSION This study indicates that the VR visualization of medical images systematically improves surgeons' analysis of preoperative breast MRI scans across several different metrics irrespective of surgeon seniority.


Sign in / Sign up

Export Citation Format

Share Document