secondary mitral regurgitation
Recently Published Documents


TOTAL DOCUMENTS

331
(FIVE YEARS 205)

H-INDEX

23
(FIVE YEARS 8)

Author(s):  
Lukas Stolz ◽  
Mathias Orban ◽  
Daniel Braun ◽  
Philipp Doldi ◽  
Martin Orban ◽  
...  

Abstract Background The impact of postero-anterior and medio-lateral mitral valve (MV) tethering patterns on outcomes in patients undergoing transcatheter edge-to-edge repair (M-TEER) for secondary mitral regurgitation (SMR) is unknown. Methods The ratio of the posterior to anterior MV leaflet angle (PLA/ALA) in MV segment 2 was defined as postero-anterior tethering asymmetry. Medio-lateral tethering asymmetry was assessed as the ratio of the medial (segment 3) to lateral (segment 1) MV tenting area. We used receiver-operating characteristics and a Cox regression model to identify cut-off values of asymmetric anteroposterior and medio-lateral tethering for prediction of 2 year all-cause mortality after TMVR. Results Among 178 SMR patients, postero-anterior tethering was asymmetric in 67 patients (37.9%, PLA/ALA ratio > 1.54). Asymmetric medio-lateral tethering (tenting area ratio > 1.49) was observed in 49 patients (27.5%). M-TEER reduced MR to ≤ 2 + in 92.1% of patients; MR reduction was less effective in the presence of asymmetric postero-anterior tethering (p = 0.02). A multivariable Cox regression model identified both types of asymmetric MV tethering to be associated with increased all-cause 2-year mortality (postero-anterior tethering asymmetry: HR = 2.77, CI 1.43–5.38; medio-lateral tethering asymmetry: HR = 2.90, CI 1.54–5.45; p < 0.01). Conclusions Asymmetric postero-anterior and medio-lateral MV tethering patterns are associated with increased 2-year mortality in patients undergoing M-TEER for SMR. A detailed echocardiographic analysis of MV anatomy may help to identify patients who profit most from M-TEER. Graphical abstract


2021 ◽  
Vol 2021 (11) ◽  
Author(s):  
Harish Sharma ◽  
Sarah Maria Birkhoelzer ◽  
Boyang Liu ◽  
Kyaw Linn Su Khin ◽  
Simiao Liu ◽  
...  

2021 ◽  
Vol 10 (20) ◽  
pp. 4748
Author(s):  
Magnus J. Hagnäs ◽  
Carmelo Grasso ◽  
Maria Elena Di Salvo ◽  
Anna Caggegi ◽  
Marco Barbanti ◽  
...  

Objectives: To investigate how the changes of left ventricle ejection fraction (LVEF) between admission and discharge affected the long-term outcome in patients who underwent percutaneous edge-to-edge mitral valve repair for secondary mitral regurgitation. Background: An acute impairment of LVEF after surgical repair of mitral regurgitation, known as afterload mismatch, has been associated with increased all-cause mortality. Afterload mismatch after percutaneous edge-to-edge mitral valve repair has been postulated to be a transient phenomenon. Methods: This study is based on a single-center, retrospective, observational registry of patients who underwent percutaneous edge-to-edge mitral valve repair with the MitraClip (Abbot Vascular) system for the treatment of symptomatic, moderate-to-severe mitral regurgitation. We included data on 399 patients who underwent percutaneous edge-to-edge mitral valve repair for secondary mitral regurgitation. Expert echocardiographers assessed LVEF before the procedure and at discharge. The patients were divided into three groups according to the difference of periprocedural LVEF measurements: unchanged (n = 318), improved (n = 40), and decreased (n = 41) LVEF. Results: The median follow-up time was 2.0 years. When adjusted for gender, NYHA class and estimated glomerular filtration rate, decreased postprocedural LVEF was associated with an increased risk of death (adjusted HR 2.05, 95% CI 1.26–3.34) and increased postprocedural LVEF with a reduced risk of death (adjusted HR 0.47, 95% CI 0.24–0.91) compared to unchanged LVEF. Conclusion: Among patients who underwent percutaneous edge-to-edge mitral valve repair, decreased postprocedural LVEF was associated with increased mortality, while improved LVEF was associated with lower mortality compared to unchanged LVEF.


Sign in / Sign up

Export Citation Format

Share Document