circuit breakers
Recently Published Documents


TOTAL DOCUMENTS

2711
(FIVE YEARS 464)

H-INDEX

41
(FIVE YEARS 7)

Author(s):  
Huangqing Xiao ◽  
Xiaowei Huang ◽  
Feng Xu ◽  
Leisi Dai ◽  
Yongjun Zhang ◽  
...  
Keyword(s):  

2022 ◽  
Vol 10 (1) ◽  
pp. 065-074
Author(s):  
Elijah Adebayo Olajuyin ◽  
Eniola Olubakinde

Power system especially the distribution system which is the closest to the consumer is very fundamental and important to a nation’s economy development and that was the reason this study titled “Evaluation of reliability of power system distribution components, a case study of Sagamu Substation, Ogun State” was carried out in response to the yawning of the consumer for reliable and stable power supply. It is indispensable to find means of shaping which component failure contributes most to the unavailability, outage or interruption of the distribution system, and how this unavailability essentially affects the customers. A year power outages data that caused as a result of failure on each of these components such as Switch gears, Supply lines (11Kv),Busbar, circuit breakers, Fuses, Switches, Outgoings feeders, Over current relays, Earth fault relays, Surge arresters, transformers e.t.c. were collected from Ibadan Electricity Distribution company (IBDEC), Sagamu Substation Zone, Ogun State and were typified in Table 1-11.The failure rate (f/yr) (λ) of transformer, switch gear, supply line (incoming),bus bars, circuit breakers, fuses, switches, outgoing feeder, over current relay, earth fault relay and surge arrester were evaluated as follows 0.0059, 0.0044, 0.0011, 0.6667, 0.0007, 0.0082, 0.0000, 0.0039, 0.0003, 0.0001 and 0.0000 respectively and others such as average outages time (hours) ,outages time hours and other basic reliability indices were calculated and illustrated in Table 12. Some of these failures were also represented in bar chart. This method relates reliability theory with the experience gained from statistics and practical knowledge of components failures and maintenance. The findings from this work revealed that fuses had the highest failure followed by transformers and the least was surge arresters and it was also discovered that the outages time was reduced during the December period. This approach can be applied to rural and urban distribution systems. This submission made reliability theory a powerful tool to assist distribution Engineers in solving difficult and complicated problems.


Author(s):  
Suliang Ma ◽  
Jianlin Li ◽  
Yiwen Wu ◽  
Chao Xin ◽  
Yaxin Li ◽  
...  

Abstract Evaluating the mechanical state of high-voltage circuit breakers (HVCBs) based on vibration information has currently become an important research direction. In contrast to the unicity of the travel–time and current–time curves, the vibration information from the different positions is diverse. These differences are often overlooked in HVCB fault identification applications. Additionally, the fault recognition results based on different location information often vary, and conflicting diagnosis results directly cause the accurate identification of the fault type to fail. Therefore, in this paper, a novel multi-information decision fusion approach is proposed based on the improved random forest (RF) and Dempster-Shafer evidence theory. In the proposed method, the diagnostic distribution of all classification regression trees (CART) in the RF is considered to solve the conflicts among the multi-information diagnosis results. Experimental results show that the proposed method eases the contradiction of multi-position diagnostic results and improves the accuracy of fault identification. Furthermore, compared to the common classifiers and probability generation methods, the effectiveness and superiority of the proposed method are verified.


Author(s):  
Xin Lin ◽  
Jia Zhang ◽  
Jianyuan Xu ◽  
Jianying Zhong ◽  
Yu Song ◽  
...  

Vestnik MGTU ◽  
2021 ◽  
Vol 24 (4) ◽  
pp. 350-360
Author(s):  
E. I. Gracheva ◽  
A. N. Gorlov ◽  
A. N. Alimova ◽  
P. P. Mukhanova

The main Russian and foreign manufacturers of low-voltage electrical devices - circuit breakers, fuses, magnetic starters, knife switches and packet switches are presented. The data of experiments for determining the resistance values of contact groups of low-voltage switching equipment are considered. The design features of the devices that determine the value of the resistances of the power circuits of low-voltage equipment are investigated and a classification is proposed depending on the design elements of the devices. A methodological approach and an algorithm for experiments and detailed analysis of the contact groups of devices are given. Experimental schemes for the study of contact groups are proposed. The data of the conducted experiments on the study of contact groups and the resistance values as a function of the flowing currents are shown. During the experiments it is revealed that the value of the resistance of the contacts changes depending on the value, type and time of exposure to current within +/-5 %. The laws that characterize the ratio of the resistance values of the structural components of devices (contact systems, thermal relay, coil of the maximum relay) have been revealed and defined. Empirical expressions and graphical dependences of the resistances of contacts and contact systems are obtained as a function of the magnitude of the rated currents of low-voltage contact equipment. The minimum sample size of the number of devices during experimental research is determined, sufficient to calculate the mathematical expectation of the resistances of the contact connections of the devices with a given accuracy. As a result of experimental studies, it is revealed that the resistance value of contacts and contact joints can increase during operation by 2-2.5 times. The established dependences of the change in contact resistance can be used to predict the technical state of electrical installations of intrashop low-voltage networks, to clarify the amount of electricity losses in shop networks up to 1 kV, and can also be used as an additional regulation for maintenance and scheduled preventive maintenance.


Author(s):  
David Maldonado ◽  
Francisco Gómez-Campos ◽  
M. B. González ◽  
Andrés Roldan ◽  
Francisco Jimenez-Molinos ◽  
...  

Abstract An in-depth analysis of resistive switching (RS) in unipolar devices is performed by means of a new simulator based on resistive circuit breakers of different features. The forming, set and reset processes are described in terms of the stochastic formation and rupture of conductive filaments of several branches in the dielectric. Both, the electric field and temperature dependencies are incorporated in the simulation. The simulation tool was tuned with experimental data of devices fabricated making use of the Ti/HfO2/Si stack. The variability and the stochastic behavior are characterized and reproduced correctly by simulation to understand the physics behind RS. Reset curves with several current steps are explained considering the rupture of different branches of the conductive filament. The simulation approach allows to connect in a natural manner to compact modeling solutions for the devices under study.