medical implants
Recently Published Documents


TOTAL DOCUMENTS

747
(FIVE YEARS 216)

H-INDEX

43
(FIVE YEARS 9)

Author(s):  
VIJAY KUMAR MEENA ◽  
PARVEEN KALRA ◽  
RAVINDRA KUMAR SINHA

Additive manufacturing (AM) of titanium (Ti) alloys has always fascinated researchers owing to its high strength to weight ratio, biocompatibility, and anticorrosive properties, making Ti alloy an ideal candidate for medical applications. The aim of this paper is to optimize the AM parameters, such as Laser Power (LP), Laser Scan Speed (LSS), and Hatch Space (HS), using Analysis of Variance (ANOVA) and Grey Relational analysis (GRA) for mechanical and surface characteristics like hardness, surface roughness, and contact angle, of Ti6Al4V ELI considering medical implant applications. The input parameters are optimized to have optimum hardness, surface roughness and hydrophilicity required for medical implants.


Metals ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 78
Author(s):  
Rafael G. Estrada ◽  
Marta Multigner ◽  
Marcela Lieblich ◽  
Santiago Fajardo ◽  
Joaquín Rams

This paper shows the results of applying a combination of high energy processing and magnesium (Mg) as an alloying element in a strategy for enhancing the degradation rate of iron (Fe) for applications in the field of non-permanent medical implants. For this purpose, Fe powder was milled with 5 wt% of Mg (Fe5Mg) and its microstructure and characterized degradation behavior. As-received Fe powder was also milled in order to distinguish between the effects due to high energy processing from those due to the presence of Mg. The powders were prepared by high energy planetary ball milling for 16 h. The results show that the initial crystallite size diminishes from >150 nm to 16 nm for Fe and 46 nm for Fe5Mg. Static degradation tests of loose powder particles were performed in Hanks’ solution. Visual inspection of the immersed powders and the X-ray diffraction (XRD) phase quantification indicate that Fe5Mg exhibited the highest degradation rate followed by milled Fe and as received Fe, in this order. The analysis of degradation products of Fe5Mg showed that they consist on magnesium ferrite and pyroaurite, which are known to present good biocompatibility and low toxicity. Differences in structural features and degradation behaviors of milled Fe and milled Fe5Mg suggest the effective dissolution of Mg in the Fe lattice. Based on the obtained results, it can be said that Fe5Mg powder would be a suitable candidate for non-permanent medical implants with a higher degradation rate than Fe.


Polymers ◽  
2022 ◽  
Vol 14 (1) ◽  
pp. 182 ◽  
Author(s):  
R. A. Ilyas ◽  
M. Y. M. Zuhri ◽  
Mohd Nor Faiz Norrrahim ◽  
Muhammad Syukri Mohamad Misenan ◽  
Mohd Azwan Jenol ◽  
...  

Recent developments within the topic of biomaterials has taken hold of researchers due to the mounting concern of current environmental pollution as well as scarcity resources. Amongst all compatible biomaterials, polycaprolactone (PCL) is deemed to be a great potential biomaterial, especially to the tissue engineering sector, due to its advantages, including its biocompatibility and low bioactivity exhibition. The commercialization of PCL is deemed as infant technology despite of all its advantages. This contributed to the disadvantages of PCL, including expensive, toxic, and complex. Therefore, the shift towards the utilization of PCL as an alternative biomaterial in the development of biocomposites has been exponentially increased in recent years. PCL-based biocomposites are unique and versatile technology equipped with several importance features. In addition, the understanding on the properties of PCL and its blend is vital as it is influenced by the application of biocomposites. The superior characteristics of PCL-based green and hybrid biocomposites has expanded their applications, such as in the biomedical field, as well as in tissue engineering and medical implants. Thus, this review is aimed to critically discuss the characteristics of PCL-based biocomposites, which cover each mechanical and thermal properties and their importance towards several applications. The emergence of nanomaterials as reinforcement agent in PCL-based biocomposites was also a tackled issue within this review. On the whole, recent developments of PCL as a potential biomaterial in recent applications is reviewed.


Author(s):  
Thomas K Varghese ◽  
Leo Antony Joji ◽  
Noel Sebastian ◽  
Niranjan V.V. ◽  
Sidheek P.A. ◽  
...  

2021 ◽  
pp. 47-52
Author(s):  
A. S. Gnedenkov ◽  
S. V. Lamaka ◽  
S. L. Sinebryukhov ◽  
V. S. Filonina ◽  
M. L. Zheludkevich ◽  
...  

2021 ◽  
Vol 13 (1) ◽  
pp. 2
Author(s):  
Inês Miranda ◽  
Andrews Souza ◽  
Paulo Sousa ◽  
João Ribeiro ◽  
Elisabete M. S. Castanheira ◽  
...  

Polydimethylsiloxane (PDMS) is an elastomer with excellent optical, electrical and mechanical properties, which makes it well-suited for several engineering applications. Due to its biocompatibility, PDMS is widely used for biomedical purposes. This widespread use has also led to the massification of the soft-lithography technique, introduced for facilitating the rapid prototyping of micro and nanostructures using elastomeric materials, most notably PDMS. This technique has allowed advances in microfluidic, electronic and biomedical fields. In this review, an overview of the properties of PDMS and some of its commonly used treatments, aiming at the suitability to those fields’ needs, are presented. Applications such as microchips in the biomedical field, replication of cardiovascular flow and medical implants are also reviewed.


Materials ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 7847
Author(s):  
Viacheslav Bazhenov ◽  
Anastasia Lyskovich ◽  
Anna Li ◽  
Vasily Bautin ◽  
Alexander Komissarov ◽  
...  

Mg alloys have mechanical properties similar to those of human bones, and have been studied extensively because of their potential use in biodegradable medical implants. In this study, the influence of different heat treatment regimens on the microstructure and mechanical and corrosion properties of biodegradable Mg–Zn–Ga alloys was investigated, because Ga is effective in the treatment of disorders associated with accelerated bone loss. Solid–solution heat treatment (SSHT) enhanced the mechanical properties of these alloys, and a low corrosion rate in Hanks’ solution was achieved because of the decrease in the cathodic-phase content after SSHT. Thus, the Mg–4 wt.% Zn–4 wt.% Ga–0.5 wt.% Y alloy after 18 h of SSHT at 350 °C (ultimate tensile strength: 207 MPa; yield strength: 97 MPa; elongation at fracture: 7.5%; corrosion rate: 0.27 mm/year) was recommended for low-loaded orthopedic implants.


Materials ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 7829
Author(s):  
Rolf G. Winnen ◽  
Kristian Kniha ◽  
Ali Modabber ◽  
Faruk Al-Sibai ◽  
Andreas Braun ◽  
...  

Osseointegration is the basis of successful dental implantology and the foundation of cementless arthroplasty and the osseointegrated percutaneous prosthetic system. Osseointegration has been considered irreversible thus far. However, controlled heating or cooling of dental implants could selectively damage the bone at the bone–implant interface, causing the reversal of osseointegration or “osseodisintegration”. This review compares five methods for implant removal, published as patent documents between 2010 and 2018, which have not yet been discussed in the scientific literature. We describe these methods and evaluate their potential for reversing osseointegration. The five methods have several technical and methodological similarities: all methods include a handpiece, a connecting device for coronal access, and a controlling device, as well as the application of mechanical and/or thermal energy. The proposed method of quantifying the temperature with a sensor as the sole means for regulating the process seems inadequate. A database used in one of the methods, however, allows a more precise correlation between a selected implant and the energy needed for its removal, thus avoiding unnecessary trauma to the patient. A flapless, microinvasive, and bone-conserving approach for removing failed dental implants, facilitating successful reimplantation, would benefit dental implantology. These methods could be adapted to cementless medical implants and osseointegrated percutaneous prosthetics. However, for some of the methods discussed herein, further research may be necessary.


Author(s):  
T. M. Amulya ◽  
K. G. Siree ◽  
T. M. Pramod Kumar ◽  
M. B. Bharathi ◽  
K. Divith ◽  
...  

The scope and applications of biomaterials have spread out throughout a broad spectrum. Particularly in pharmacy, biomaterials are an attractive choice because they can be modified to decrease toxicity, increase the targeting ability among many other aspects of drug delivery. Extensive studies have led to the development of many metal-based, ceramic, biocompatible and biodegradable biomaterials for medical purposes among many others. The utilization of 3D printing in this discipline is a very novel research subject with infinite potential. Personalized and customized nasal implants are a great option to increase patient compliance and 3D printed accurate anatomical structures are rendered to be effective tools of learning. One of the disadvantages of biomaterial-based implants is the formation of a thick fibrous capsule formation around the implant, others being breakage, soft tissue loss and so on. Regulatory aspects are less explored for nasal implants. 3D printing is a unique technique that allows for a high degree of customisation in pharmacy, dentistry and in designing of medical devices. Current research in 3D printing indicates towards reproducing an organ in the form of a chip; paving the way for more studies and opportunities to perfecting the existing technique.


2021 ◽  
Vol 2 (11) ◽  
pp. 1168-1169
Author(s):  
Tadeusz Hryniewicz

This work is to reveal and present some contemporary surface treatment methods used in view of improving performance of parts of a variety of metals and alloys. Stainless steels and titanium alloys are with the group of particular focus, important for medical implants in chirurgy and instruments used in dentistry. Improved, anti-corrosion properties and mechanical strength of materials are the primary features for examination.


Sign in / Sign up

Export Citation Format

Share Document