ultrasound system
Recently Published Documents


TOTAL DOCUMENTS

836
(FIVE YEARS 147)

H-INDEX

33
(FIVE YEARS 3)

Molecules ◽  
2022 ◽  
Vol 27 (2) ◽  
pp. 541
Author(s):  
Luis M. Carrillo-Lopez ◽  
Bianka Y. Cruz-Garibaldi ◽  
Mariana Huerta-Jimenez ◽  
Ivan A. Garcia-Galicia ◽  
Alma D. Alarcon-Rojo

The effect of high-intensity ultrasound (HIU) system (bath, 37 kHz and 90 W/cm2; or probe, 24 kHz and 400 W) and application time (25 or 50 min, one-side exposition) on the properties of bovine Longissimus lumborum after 7 d of storage at 4 °C was studied. The bath system significantly increased the lightness of the muscle, while other color parameters (a*, b*, hue, and chroma) were not different from the control. The water holding capacity and shear force decreased significantly (3.1–5% and 0.59–0.72 kgf, respectively) in sonicated meat independently of the system, favoring the tenderization of the muscle after storage. Microstructural changes observed in the HIU-exposed surface provided evidence of a higher area of interfibrillar spaces (1813 vs. 705 µm2 in the control), producing tenderization of the muscle, compared with the control. HIU significantly increased counts of total aerobic and coliform bacteria, especially after 50 min of ultrasonication. HIU also increased lactic acid bacterial counts in the bath system. Single-sided muscle exposition to ultrasound may produce sufficient significant changes in muscle properties, which could decrease long treatment times that would be needed for the exposition of both sides. HIU in bath systems increases tenderness by modifying meat ultrastructure, with no significant changes in physicochemical parameters. Nevertheless, microbiological quality may need to be considered during the process due to a slight increase in bacterial counts.


2021 ◽  
Author(s):  
Jun Umehara ◽  
Norio Fukuda ◽  
Shoji Konda ◽  
Masaya Hirashima

Accurate measurement of muscle morphology is crucial for assessing skeletal muscle capacity. Although the freehand three-dimensional ultrasound (3DUS) system is a promising technique for assessing muscle morphology, its accuracy has been validated mainly in terms of volume by examining lower limb muscles. The purpose of this study was to validate 3DUS in the measurements of 3D surface shape and volume by comparing them with MRI measurements while ensuring the reproducibility of participant posture by focusing on the shoulder muscles. The supraspinatus, infraspinatus, and posterior deltoid muscles of 10 healthy males were scanned using 3DUS and MRI while secured by an immobilization support customized for each participant. A 3D surface model of each muscle was created from the 3DUS and MRI methods, and the agreement between them was assessed. For the muscle volume, the mean difference between the two models was within 0.51 cm3 for all muscles. For the surface shape, the distances between the closest points of the two models was calculated for every point on the 3DUS surface model. The results showed that the median (third quartile) of the distances was less than 1.21 mm (1.89 mm) for all muscles. These results suggest that, given the above error is permitted, 3DUS can be used as an alternative to MRI in measuring volume and surface shape, even for the shoulder muscles.


2021 ◽  
Author(s):  
Deepak Raina ◽  
Hardeep Singh ◽  
Subir Kumar Saha ◽  
Chetan Arora ◽  
Ayushi Agarwal ◽  
...  

2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Reza Fotouhi ◽  
Atieh Najafi Semnani ◽  
QianWei Zhang ◽  
Scott J. Adams ◽  
Haron Obaid

Abstract Objective To develop a collision engine (haptic force feedback simulator) compatible with a 5-degrees-of-freedom (DOF) haptic wand. This has broad applications such as telerobotic ultrasound systems. Integrating force feedback into systems is critical to optimize remote scanning. A collision engine compatible with a 5-DOF haptic wand was developed based on the Gilbert–Johnson–Keerthi algorithm. The collision engine calculated force during collision between the wand and a virtual object based on code developed using MATLAB. A proportional force was subsequently returned to a user via the haptic wand, thereby simulating the collision force for the user. Three experiments were conducted to assess the accuracy of the collision engine on curved and flat surfaces. Results The average errors in calculation of distances between the wand and virtual object were 2.1 cm, 3.4 cm, and 4.2 cm for the model of the human hand, cylinder, and cuboid, respectively. The collision engine accurately simulated forces on a flat surface, though was less accurate on curved surfaces. Future work will incorporate haptic force feedback into a telerobotic ultrasound system. The haptic force simulator presented here may also be used in the development of ultrasound simulators for training and education.


2021 ◽  
Vol 12 ◽  
Author(s):  
Josanne S. de Maar ◽  
Charis Rousou ◽  
Benjamin van Elburg ◽  
Hendrik J. Vos ◽  
Guillaume P.R. Lajoinie ◽  
...  

Chemotherapy efficacy is often reduced by insufficient drug uptake in tumor cells. The combination of ultrasound and microbubbles (USMB) has been shown to improve drug delivery and to enhance the efficacy of several drugs in vitro and in vivo, through effects collectively known as sonopermeation. However, clinical translation of USMB therapy is hampered by the large variety of (non-clinical) US set-ups and US parameters that are used in these studies, which are not easily translated to clinical practice. In order to facilitate clinical translation, the aim of this study was to prove that USMB therapy using a clinical ultrasound system (Philips iU22) in combination with clinically approved microbubbles (SonoVue) leads to efficient in vitro sonopermeation. To this end, we measured the efficacy of USMB therapy for different US probes (S5-1, C5-1 and C9-4) and US parameters in FaDu cells. The US probe with the lowest central frequency (i.e. 1.6 MHz for S5-1) showed the highest USMB-induced intracellular uptake of the fluorescent dye SYTOX™ Green (SG). These SG uptake levels were comparable to or even higher than those obtained with a custom-built US system with optimized US parameters. Moreover, USMB therapy with both the clinical and the custom-built US system increased the cytotoxicity of the hydrophilic drug bleomycin. Our results demonstrate that a clinical US system can be used to perform USMB therapy as efficiently as a single-element transducer set-up with optimized US parameters. Therefore, future trials could be based on these clinical US systems, including validated US parameters, in order to accelerate successful translation of USMB therapy.


Author(s):  
Jaebum Park ◽  
Yeongdae Kim ◽  
Junyeon Kim ◽  
Tai-Kyong Song

Sign in / Sign up

Export Citation Format

Share Document