laa closure
Recently Published Documents


TOTAL DOCUMENTS

98
(FIVE YEARS 61)

H-INDEX

6
(FIVE YEARS 2)

Author(s):  
Mohammad Mahdi Peighambari ◽  
Firoozeh Moradkarami ◽  
Anita Sadeghpour ◽  
Bahador Baharestani ◽  
Alireza Alizadeh-Ghavidel ◽  
...  

Background: Several surgical procedures such as excision or exclusion are recommended for the closure of the left atrial appendage (LAA). This study was conducted with the aim to evaluate the success rate of different surgical techniques for LAA closure, their respective complications, and the rate of post-surgical cerebrovascular accident (CVA). Methods: This retrospective study included 150 consecutive patients who underwent LAA closure most commonly after mitral valve surgery within 3 to 6 months after surgery. An expert echocardiographic fellow collected the data on patients’ surgical LAA closure methods and history of CVA, types of prosthetic valves, mortality, and bleeding. Results: The failure rate for complete LAA closure was 36.7% (55 patients) in our study. The greatest success rate of complete LAA closure was seen in purse-string method (75.5%), followed by resection method (71.4%), while the lowest success rate (≈ 33.3%) was observed in ligation method. A significant relationship was observed between clots on the surface of metallic valve and postoperative CVA (P = 0.001; likelihood ratio: 32). significant relationship between partial LAA closure and the incidence of post-surgical CVA (P > 0.050). Conclusion: We observed the highest success rate of complete LAA closure in purse-string method followed by resection method. Interestingly, our results showed that despite the higher rate of residual LAA clot in cases of partial LAA closure, the occurrence of post-surgical CVA was mostly related to the presence of clots on the surface of metallic mitral prostheses rather than the presence of partial LAA closure.


Author(s):  
Ahmet Güner ◽  
Ezgi Gültekin Güner ◽  
Macit Kalçık ◽  
Mehmet Özkan

2021 ◽  
Author(s):  
Yoichi Takaya ◽  
Rie Nakayama ◽  
Fumi Yokohama ◽  
Norihisa Toh ◽  
Koji Nakagawa ◽  
...  

Abstract Left atrial appendage (LAA) size is crucial for determining the indication of transcatheter LAA closure. The aim of this study was to evaluate the differences in LAA morphology according to the types of atrial fibrillation (AF). A total of 340 patients (mean age: 65 ± 15 years) who underwent transesophageal echocardiography (TEE) were included. Patients were classified into non-AF (n = 105), paroxysmal AF (n = 86), persistent AF (n = 87), or long-standing persistent AF (n = 62). LAA morphology, including LAA ostial diameter and depth, was assessed using TEE. Patients with long-standing persistent AF had larger LAA ostial diameter and depth, greater LAA lobes, and lower LAA flow velocity. The maximum LAA ostial diameter was 19 ± 4 mm in patients with non-AF, 21 ± 4 mm in patients with paroxysmal AF, 23 ± 5 mm in patients with persistent AF, and 26 ± 5 mm in patients with long-standing persistent AF. LAA ostial diameter was increased by 2 or 3 mm with the progression of AF. LAA ostial diameter was correlated with LA volume index (r = 0.37, p < 0.01) and the duration of continuous AF (r = 0.30, p < 0.01), but not with age or the period from the onset of AF. In conclusion, LAA size, which is the determinant for selecting device size of transcatheter LAA closure, was increased with the progression of AF. Our findings have potential implications for therapeutic strategy of transcatheter LAA closure.


Author(s):  
Mahmoud Wehbe ◽  
Marc Albert ◽  
Thorsten Lewalter ◽  
Taoufik Ouarrak ◽  
Jochen Senges ◽  
...  

Abstract Background The aim of this study was to describe outcomes of patients undergoing surgical ablation for atrial fibrillation (AF) as either stand-alone or concomitant cardiosurgical procedures in Germany. Methods Patients with AF undergoing concomitant or stand-alone surgical ablation were included in the registry. Cardiac surgery centers across Germany were invited to participate and sought to enroll 1,000 consecutive patients. Data was obtained through electronic case report forms. The protocol mandated follow-up interviews at 1 year. Results Between January 2017 and April 2020, 17 centers enrolled 1,000 consecutive patients. Among concomitant surgical patients (n = 899), paroxysmal AF was reported in 55.4% patients. Epicardial radio frequency (RF) bilateral pulmonary vein isolation (PVI) with excision of the left atrial appendage (LAA) was the most common operative strategy. In the stand-alone cohort (n = 101), persistent AF forms were reported in 84.1% of patients. Moderate-to-severe symptoms were reported in 85.1%. Sixty-seven patients had previously underwent at least two failed catheter ablative procedures. Thoracoscopic epicardial RF bilateral PVI and completion of a “box-lesion” with LAA closure were frequently preformed. Major cardiac and cerebrovascular complications occurred in 38 patients (4.3%) in the concomitant group. No deaths were reported in the stand-alone group. At discharge, sinus rhythm was achieved in 88.1% of stand-alone and 63.4% concomitant patients. Conclusion The CArdioSurgEry Atrial Fibrillation registry provides insights into surgical strategies for AF ablation in a considerable cohort across Germany. This in-hospital data demonstrates that concomitant and stand-alone ablation during cardiac surgery is safe and effective with low complication rates.


2021 ◽  
Vol 3 (12) ◽  
pp. 1419-1421
Author(s):  
Hemal Bhatt ◽  
Lucy M. Safi ◽  
Vladimir Jelnin ◽  
Tilak K.R. Pasala ◽  
Grant R. Simons

2021 ◽  
Author(s):  
Yoichi Takaya ◽  
Rie Nakayama ◽  
Fumi Yokohama ◽  
Norihisa Toh ◽  
Koji Nakagawa ◽  
...  

Abstract Left atrial appendage (LAA) size is crucial for determining the indication of transcatheter LAA closure. The aim of this study was to evaluate the differences in LAA morphology according to the types of atrial fibrillation (AF). A total of 340 patients (mean age: 65 ± 15 years) who underwent transesophageal echocardiography (TEE) were included. Patients were classified into non-AF (n = 105), paroxysmal AF (n = 86), persistent AF (n = 87), or long-standing persistent AF (n = 62). LAA morphology, including LAA ostial diameter and depth, was assessed using TEE. Patients with long-standing persistent AF had larger LAA ostial diameter and depth, greater LAA lobes, and lower LAA flow velocity. The maximum LAA ostial diameter was 19 ± 4 mm in patients with non-AF, 21 ± 4 mm in patients with paroxysmal AF, 23 ± 5 mm in patients with persistent AF, and 26 ± 5 mm in patients with long-standing persistent AF. LAA ostial diameter was increased by 2 or 3 mm with the progression of AF. LAA ostial diameter was correlated with LA volume index (R = 0.37, P < 0.01) and the duration of continuous AF (R = 0.30, P < 0.01), but not with age or the period from the onset of AF. LAA size, which is the determinant for selecting device size of transcatheter LAA closure, was increased with the progression of AF. Our findings have potential implications for therapeutic strategy of transcatheter LAA closure.


Author(s):  
Carola Gianni ◽  
J David Burkhardt ◽  
Domenico G Della Rocca ◽  
Andrea Natale ◽  
Rodney P Horton
Keyword(s):  

Author(s):  
William Hucker ◽  
Aneesh Bapat ◽  
Alan Hanley ◽  
Samuel Bernard ◽  
Phillippe Bertrand ◽  
...  

Background: Surgical or percutaneous occlusion of the left atrial appendage (LAA) is increasingly used for thromboembolic protection in atrial fibrillation. Incomplete LAA closure may increase risk of thrombosis and thromboembolism, and therefore approaches to address residual communications are needed. Objective: To analyze the technique of closing an incompletely occluded LAA and subsequent patient outcomes. Methods: We performed a retrospective analysis of 5 consecutive patients who presented for completion of LAA closure. Results: Four patients were male, mean age 75, average CHA2DS2-VASc score 5.4, and four had prior surgical LAA ligation. One patient had previously had a WATCHMAN device placed for whom a 3D printed model was created from preprocedural imaging data to guide Amplatzer occluder device selection for closure. The residual LAA communication maximal diameter averaged 6.2 mm (range 5-8mm). In 4 of 5 cases, an ablation catheter was used to enter the LAA. The residual LAA communication was closed with either an Amplatzer occluder (n=3) or a WATCHMAN device (n=2). No procedural complications occurred, and no residual leak remained afterwards. No neurologic events occurred during follow up (average 603 days, range 155-1177 days). Anticoagulation or dual antiplatelet therapy was stopped following a transesophageal echo (TEE) ³ 6 weeks after the procedure demonstrated no residual communication in 4 of 5 patients, and after 20 weeks in the fifth patient without a follow up TEE. Conclusion: Large residual LAA communications after LAA occlusion attempts can be successfully and safely closed percutaneously using either Amplatzer occluder devices or WATCHMAN devices.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Nicolas Lellouche ◽  
Raphaele Arrouasse ◽  
Julien Ternacle ◽  
Romain Gallet ◽  
Jean-Sylvain Hermida ◽  
...  

Abstract Background Percutaneous left atrial appendage (LAA) closure is an alternative to oral anticoagulation (OAC) for atrial fibrillation (AF) patients with high thromboembolism risk, particularly with contraindications to OAC. The LAA itself could possess proarrhythmogenic properties. As patients undergoing LAA closure could be candidates for cardioversion or ablation, we aimed to evaluate AF disease progression following LAA closure and the outcome of patients undergoing a rhythm control strategy after the procedure. Methods The prospective multicenter French Nationwide Observational LAA Closure Registry (FLAAC) comprises 33 French interventional cardiology departments. Patients were included if they fulfilled the following criteria: history of non-valvular AF, successful LAA closure and long-term ECG follow-up. Results A total of 331 patients with successful LAA closure were enrolled in the study. Patients mean age was 75.4 ± 0.5 years. The study population was characterized by a high thromboembolic risk (CHA2DS2-VASc score: 4.5 ± 0.1) and frequent comorbidities. The median follow-up was 11.9 months. One hundred and nineteen (36.0%) patients were in sinus rhythm (SR) at baseline. Among SR patients, documented AF was observed in 16 (13.4%) patients whereas 15 (7.1%) patients in AF at baseline restored SR, at the end of follow up. Finally, only 13 patients (4%) underwent procedures to restore SR without complications during the follow-up. Conclusions The vast majority of patients undergoing LAA closure have the same AF status at baseline and one year after the index procedure. During the follow-up, a very small proportion (4%) of our population underwent procedures to restore SR without complications whatever the post-procedural antithrombotic strategy was.


Sign in / Sign up

Export Citation Format

Share Document