pipe heat
Recently Published Documents


TOTAL DOCUMENTS

800
(FIVE YEARS 292)

H-INDEX

41
(FIVE YEARS 11)

Author(s):  
Liu Shuailing ◽  
Ma Guoyuan ◽  
Jia Xiaoya ◽  
Xu Shuxue ◽  
Wu Guoqiang

2021 ◽  
Vol 43 (4) ◽  
pp. 34-42
Author(s):  
V.S. Oliinyk ◽  
P.G. Krukovskyi ◽  
A.I. Deineko

The results of the study of the intensification of the heat transfer process under forced air convection in the annular gap of a pipe-in-pipe heat exchanger with a spiral-wire intensifier located near the outer surface of the inner pipe are presented. The intensifier does not touch the pipe surface. The height of the wire of the intensifier is taken as 1.5 mm. The change in the winding pitch varied within the range of 12-20mm. Boundary conditions of the first kind + 20 ° C are set on the inner surface of the inner pipe. The temperature of the air moving in the annular gap is 300 ° C. The air velocity varied from 6 to 15 m / s. For the CFD model of a pipe-in-pipe heat exchanger, the use of a computational grid with 4.7 million elements is justified. The CFD model was validated using literature data. Based on the analysis of the ratio of the intensified Nusselt number to the Nusselt number for a smooth pipe, a 1.7-fold increase in heat transfer was found for Reynolds numbers from 5000 to 7000. This result is explained by the periodic destruction of the boundary layer along the pipe. With a further increase in Reynolds numbers to 13000, the intensification of heat transfer decreases from 1.7 to 1.3, which is explained by an increase in the vortex zone immediately behind the wire and the appearance of recirculation zones that make a minimum contribution to heat transfer. It has been determined that the spiral-wire intensifier with the maximum possible step of 20 mm contributes to the greatest increase in heat transfer by 1.7 times and has the smallest coefficient of hydraulic friction of 0.076-0.06 for the studied range of Reynolds numbers.


Author(s):  
M.L.R. Chaitanya Lahari ◽  
◽  
P.H.V. Sesha Talpa Sai ◽  
K.V. Sharma ◽  
K.S. Narayanaswamy ◽  
...  

The Nusselt number, overall heat transfer, and convective heat transfer coefficients of glycerol-water-based Cu nanofluids flowing in a parallel flow double pipe heat exchanger are estimated using CFD analysis. Single-phase fluid approach technique is used in the analysis. Ansys 19.0 workbench was used to create the heat exchanger model. Heat transfer tests with nanofluids at three flow rates (680<Re<1900) are carried out in a laminar developing flow zone. For testing, a 500 mm long concentric double pipe heat exchanger with tube dimensions of ID=10.2 mm, OD= 12.7 mm, and annulus dimensions of ID=17.0 mm, OD= 19.5 mm is employed. Copper is utilized for the tube and annulus material. This study employed three-particle volume concentrations of 0.2 percent, 0.6 percent, and 1.0 percent. The mass flow rates of hot water in the tube are 0.2, 0.017, and 0.0085 kg/s, while the mass flow rates of nanofluids in the annulus are 0.03, 0.0255, and 0.017 kg/s. The average temperature of nanofluids is 36°C, whereas hot water is 58°C. In comparison to base liquid, the overall heat transfer coefficient and convective HTC of 1.0 percent copper nanofluids at 0.03 kg/s are raised by 26.2 and 46.2 percent, respectively. The experimental findings are compared to CFD values, and they are in close agreement.


2021 ◽  
Vol 92 (11-5) ◽  
Author(s):  
Abdugaffor Khurmamatov ◽  
Ganisher Rakhimov ◽  
Feruzbek Murtazaev