Journal de Physique de la SOAPHYS
Latest Publications


TOTAL DOCUMENTS

42
(FIVE YEARS 42)

H-INDEX

1
(FIVE YEARS 1)

Published By SOAPHYS (Societe Ouest Africaine De Physique)

2630-0958
Updated Wednesday, 30 June 2021

2021 ◽  
Vol 2 (2) ◽  
pp. C20A15-1-C20A15-5
Author(s):  
Kalifa Palm ◽  
◽  
Roland Lankouandé ◽  
Boukaré Ouédraogo ◽  
Oumar Sanogo ◽  
...  

The burning of industrial, agricultural wastes and garbage into ashes is source of significant air pollution due to the following gas components CO, CO2, CH4, C2H4, H2O… etc. Thermodestruction remains one of the effective technologies used in the depollution of these components. This paper is devoted to the modelling of the thermodestruction in a cylindrical incinerator of gas waste produced by the combustion of garbage. Dimensionless transfer’s equations are solved using an implicit numerical scheme, Thomas and Gauss algorithms. We analyze the influence of the mass rate of the inlet smoke on the effectiveness of depollution.


2021 ◽  
Vol 2 (2) ◽  
pp. C20A24-1-C20A24-6
Author(s):  
Moussa Koné ◽  
◽  
Fadaba Danioko ◽  
Mamadou Dansoko ◽  
Sid-Ali Addouche ◽  
...  

La transition énergétique vers les énergies renouvelables a poussé les pays notamment ceux du sahel à utiliser au mieux les énergies renouvelables. Parmi ces énergies renouvelables, le biogaz contribue aux défis énergétiques et environnementaux des populations. Dans ce papier, nous proposons une méthodologie capable à la fois de produire du froid et d’électricité à partir des déchets organiques. L’approche proposée donne une étude du potentiel et de la disponibilité des déchets (analyse de la disponibilité, caractérisation des déchets, etc.), une conception et dimensionnement du système de conversion (centrale à déchets), une modélisation et simulation du processus de production de froid et d’électricité sous le logiciel « Thermoptim ». Les résultats obtenus notamment pour le cas de Bamako (capitale du Mali) donnent la quantité journalière de biogaz (déchets méthanisables) de 1544 tonnes/j dont celle du méthane est de 14479,084 m3/j et celle de l’énergie primaire est de 143,922 MWh/j. L’énergie thermique convertible en froid est de 57,93 MW/j et l’énergie électrique est de 52,475 MW/j. Par ailleurs, la simulation a permis d’une part de comprendre le processus thermodynamique, d’obtenir des résultats intéressants sur l’analyse de la biomasse soit 60,51% de matières sèches et 39,08 % de matières organiques pour le cas de Bamako et d’autre part de faire les analyses environnementale et économique. L’application de ce travail peut combler un déficit énergétique par rapport à la demande énergétique (froid, électricité) qui croit 10% environ par an.


2021 ◽  
Vol 2 (2) ◽  
pp. C20A27-1-C20A27-17
Author(s):  
Darius B. A. Gnihatin ◽  
◽  
Agnidé Emmanuel Lawin ◽  
Aristide B. Akpo ◽  

The deficit of last decade rain in West Africa and particularly in Benin pushes us to make the analysis of tendencies of the dry sequences of the tabular stations from daily raining data. The general objective of this survey is the research of rupture and tendency in the dry sequence sets in the period from 1970 to 2009 from daily raining data of the tabular stations of Benin. We have extract of data daily raining of six stations of Benin, the maximal dry sequence length and the dry sequence average in the period from1970 to 2009 and we analyzed the variation of maxima of length of dry sequences and their average on the period from 1970 to 2009.Then, to deepen analyses of tendency, we achieved some statistical tests have been applied to the set of the maxima dry sequence with the help of the software Khronostat. From the results, we can retain the existence of a reduction tendency of the dry sequence with breakpoint in 2006 in the station’s Cotonou. In opposition, an increase tendency with breakpoint in 1978 in the station’s Natitingou. And, a stationary tendency without breakpoint in the set of maxima of dry sequence length to the station of Bohicon, Savè, Parakou and Kandi.


2021 ◽  
Vol 2 (2) ◽  
pp. C20A25-1-C20A25-9
Author(s):  
Souleymane Ouédraogo ◽  
◽  
Augustin S Zongo ◽  
Jean-Fidèle N’Zihou ◽  
Tizane Daho ◽  
...  
Keyword(s):  

Les paramètres météorologiques et radiométriques tels que le rayonnement solaire influencent fondamentalement la rentabilité et la performance des systèmes de conversion de l’énergie solaire. L’optimisation des convertisseurs d’énergie solaire dépend du modèle de rayonnement solaire utilisé. Cette étude porte sur l’estimation du rayonnement solaire incident global sur le plan horizontal et incliné sur le site de la ville de Ouagadougou. L’étude des quatre modèles de rayonnement solaire permet d’estimer le rayonnement solaire global incident sur un plan horizontal et incliné. Les différents modèles sont évalués sur une base graphique et statistique, en utilisant les indicateurs du coefficient de détermination de R^2, de l’erreur quadratique moyenne (RMSE) et le pourcentage de l'erreur absolue moyenne (MAPE). Les résultats obtenus avec les quatre modèles semi-empiriques ont été comparés avec les valeurs expérimentales instantanées mesurées sur le site de Ouagadougou. Les résultats montrent que le modèle semiempirique d’Eufrat présente la meilleure estimation du rayonnement solaire global pour le site de Ouagadougou.


2021 ◽  
Vol 2 (2) ◽  
pp. C20A26-1-C20A26-7
Author(s):  
Daouda Sawadogo ◽  
◽  
Ousmane Coulibaly ◽  
Tizane Daho
Keyword(s):  

Cette étude porte principalement sur la modélisation et la simulation d’un bâtiment à usage d’habitation et orienté vers le Bâtiment à Energie POSitive (BEPOS). C’est un bâtiment de niveau R+1 et notre étude a portée au niveau de Rez-De-Chaussée. Le Logiciel KoZiBu nous a permis d’entreprendre une simulation du bâtiment en situation de référence et optimisé. Les conclusions de ces travaux, ont montré pour les charges de climatisation que le bâtiment en situation optimisé présente une économie d’énergie de 20,16% par rapport au bâtiment en situation de référence. De plus la production d’énergie à l’aide des panneaux photovoltaïques sous PV SYST est comparée avec les consommations d’énergie électrique du bâtiment pour analyser son autonomie énergétique. Une étude comparée au niveau de la variation de température à l’intérieur du bâtiment étudié en situation de référence et optimisé a été réalisée. Enfin, une étude économique et écologique du projet d’isolation du bâtiment nous a permis de savoir que son temps de retour est de 7 ans 5 mois et permet d’éviter l’émission de 256,5 tonnes eq de CO2 en 50 ans.


2021 ◽  
Vol 2 (2) ◽  
pp. C20A28-1-C20A28-9
Author(s):  
Modou Badiane ◽  
◽  
Prince Abdoul Aziz Honadia ◽  
Fabé Idrissa Barro ◽  
◽  
...  

A theoretical and experimental study of a conventional boost converter is presented. Based on the real behavior of the components, the conventional boost converter model dealing with both inductive and capacitive losses as well as switching losses is introduced. From this model, the detailed analytical expressions of the voltage gain factor and the conversion efficiency are established taking into account the losses due to parasitic resistances and switching losses. The behavior of the converter is then analyzed by simulating the voltage gain factor and the conversion efficiency as a function of the duty cycle. The converter prototype was manufactured and a set of experimental measurements was made; these measurements made it possible to demonstrate that the proposed theoretical models were reliable for a large range of duty cycle for the boost converter.


2021 ◽  
Vol 2 (2) ◽  
pp. C20A23-1-C20A23-5
Author(s):  
Alfred Dèdonougbo Dohou ◽  
◽  
Koto Gabin N’Gobi ◽  
Clément Adéyèmi Kouchade ◽  
Basile Bruno Kounouhewa

La jacinthe d’eau (Eichornia crassipes) est une plante aquatique invasive. Elle est devenue un véritable fléau dans les eaux du monde entier en générale et dans les eaux du lac Nokoué en particulier rendant difficile la navigation aux usagers locaux de la plus grande cité lacustre du Bénin. Devant cette urgence, nous pensons que la biomasse lignocellulosique issue de l’exploitation de la jacinthe peut constituer une voie prometteuse permettant son utilisation comme matière première pour la production du bio méthane. De plus, l’urgence de trouver d’autres sources d’énergie énergies renouvelables suite à l’amenuisement des énergies fossiles n’est plus à démontrer. L’objectif de notre travail est d’évaluer le pouvoir méthanogène de la jacinthe d’eau prélevée sur le lac Nokoué à Ganvié dans la commune de So-Ava au Bénin. Ainsi, nous avons introduit à titre expérimental, dans un bidon de 25litres, 150g de jacinthe d’eau hachée avec 1litre d’inoculum. Après 40 jours de fermentation, il a été produit 5169,025 ml de méthane ou 34,46 ml/g CH4 soit 58% du volume total de biogaz produit. Le taux du sulfure d’hydrogène remarqué dans le biogaz produit permet de conclure que la concentration en soufre ou en ses dérivés dans l’eau du lac Nokoué est importante. La jacinthe d’eau (Eichornia crassipes) peut être un bon substrat pour la bio méthanisation anaérobie en milieu lacustre.


2021 ◽  
Vol 2 (2) ◽  
pp. C20A19-1-C20A19-7
Author(s):  
Fati Amadou-Oumarou ◽  
◽  
Souleymane Ouédraogo ◽  
Adrien Sanembaye ◽  
Amadou Konfé ◽  
...  

The energy demand in buildings sector is always increasing due to the climate, the economic growth, and also the need for thermal comfort. The aim of this paper is to find a way that can significantly reduce the energy demand for a building through an improvement of the design of its thermal envelope. Within this work, we utilized the thermophysical properties of four building materials: three local materials (compressed earth block (BTC), lateritic block (BLT), and raw earth), and one modern (Hollow cement). The numerical optimization of the building design has been performed dynamically by Comsol 5.3a software: the case study is Ouagadougou and the surface is 100m2. Also, the temporal variations in the inside of the room, as well as the internal and external temperatures of the walls and the ceiling with four different materials, have been determined. The result of the simulation shows that, for BLT, the maximum of ambiante temperature is obtained 308K around 22h, for Adobe it is 308.8K around 21h, for BTC it was 309.2K at 19h30, and finally for cement block it is 310K around 17. We can safely say that BLT is the material leading to the lowest average daily indoor temperature variation, thus leading to the reduction of air conditioning load and the need for thermal comfort and around the order of 4KW of energy saving can be obtained.


2021 ◽  
Vol 2 (2) ◽  
pp. C20A21-1-C20A21-5
Author(s):  
Hilaire Kougbeagbede ◽  
◽  
Sounmaïla Moumouni ◽  
Loïc S. Adjikpe ◽  
Joseph A. Adechinan ◽  
...  

La distribution granulométrique de la taille des gouttes de pluie joue un rôle crucial dans l’étude de la microphysique des précipitations, l’érosion des sols et la télécommunication. Elle est souvent modélisée par les lois exponentielle, lognormale, gamma standard ou gamma généralisé. Jusqu’à présent en Afrique de l’ouest, la distribution granulométrique de la taille des gouttes de pluie est modélisée par la loi gamma ou lognormale. La présente étude s’est intéressée à la modélisation de la distribution par la loi gamma généralisée normalisée par un double moment. Les données exploitées sont les spectres de gouttes de pluie de durée une minute de la ligne de grain du 25/07/2006. Elles ont été recueillies au cours de la campagne AMMA à Djougou (Nord-Ouest du Bénin) en 2006. Les résultats obtenus montrent que la loi gamma généralisée normalisée par un double moment estime mieux les moments que la loi gamma standard normalisée par un double moment proposé par Moumouni et al., 2008.


2021 ◽  
Vol 2 (2) ◽  
pp. C20A16-1-C20A16-7
Author(s):  
Malick Sow ◽  

We report in this paper the total energies of the 2p2 1D, 3d2 1G, 4f2 1I doubly excited states of Helium isoelectronic sequence with nuclear charge Z ≤ 20. Calculations are performed using the Modified Atomic Orbital Theory (MAOT) [1;2] in the framework of a variational procedure. The purpose of this study required a mathematical development of the Hamiltonian applied to Slater-type wave function [3] combining with Hylleraas-type wave function [4]. The study leads to analytical expressions which are carried out under special MAXIMA computational program. This proposed MAOT variational procedure, leads to accurate results in good agreement as well as with available other theoretical results than experimental data. In the present work, a new correlated wave function is presented to express analytically the total energies for each 2p2 1D, 3d2 1G, 4f 2 1I Doubly Excited States (DES) in the He-like systems. The present accurate data may be a useful guideline for future experimental and theoretical studies in the (nl2 ) systems.


Sign in / Sign up

Export Citation Format

Share Document