scholarly journals Channel-levee evolution in combined contour current–turbidity current flows from flume-tank experiments

Geology ◽  
2020 ◽  
Vol 48 (4) ◽  
pp. 353-357 ◽  
Author(s):  
Elda Miramontes ◽  
Joris T. Eggenhuisen ◽  
Ricardo Silva Jacinto ◽  
Giovanni Poneti ◽  
Florian Pohl ◽  
...  

Abstract Turbidity currents and contour currents are common sedimentary and oceanographic processes in deep-marine settings that affect continental margins worldwide. Their simultaneous interaction can form asymmetric and unidirectionally migrating channels, which can lead to opposite interpretations of paleocontour current direction: channels migrating against the contour current or in the direction of the contour current. In this study, we performed three-dimensional flume-tank experiments of the synchronous interaction between contour currents and turbidity currents to understand the effect of these combined currents on channel architecture and evolution. Our results show that contour currents with a velocity of 10–19 cm s−1 can substantially deflect the direction of turbidity currents with a maximum velocity of 76–96 cm s−1, and modify the channel-levee system architecture. A lateral and nearly stationary front formed on the levee located upstream of the contour current, reduced overspill and thus restrained the development of a levee on this side of the channel. Sediment was preferentially carried out of the channel at the flank located downstream of the contour current. An increase in contour-current velocity resulted in an increase in channel-levee asymmetry, with the development of a wider levee and more abundant bedforms downstream of the contour current. This asymmetric deposition along the channel suggests that the direction of long-term migration of the channel form should go against the direction of the contour current due to levee growth downstream of the contour current, in agreement with one of the previously proposed conceptual models.

JOIDES drilling results provide new evidence concerning facies patterns on evolving passive margins that strengthens and extends hypotheses constructed from studies of morphology, seismic reflexion data and shallow samples on modern margins, and from field geologic studies of uplifted ancient margins. On the slopes and rise, gravity-controlled mechanisms - turbidity currents, debris flows, slides and the like - play the dominant role in sediment transport over the long term, but when clastic supplies are reduced, as for example during rapid transgressions, then oceanic sedimentation and the effects of thermohaline circulation become important. Sedimentary facies models used as the basis of unravelling tectonic complexities of some deformed margins, for example in the Mesozoic Tethys, may be too simplistic in the light of available data from modern continental margins.


Author(s):  
C.L. Woodcock

Despite the potential of the technique, electron tomography has yet to be widely used by biologists. This is in part related to the rather daunting list of equipment and expertise that are required. Thanks to continuing advances in theory and instrumentation, tomography is now more feasible for the non-specialist. One barrier that has essentially disappeared is the expense of computational resources. In view of this progress, it is time to give more attention to practical issues that need to be considered when embarking on a tomographic project. The following recommendations and comments are derived from experience gained during two long-term collaborative projects.Tomographic reconstruction results in a three dimensional description of an individual EM specimen, most commonly a section, and is therefore applicable to problems in which ultrastructural details within the thickness of the specimen are obscured in single micrographs. Information that can be recovered using tomography includes the 3D shape of particles, and the arrangement and dispostion of overlapping fibrous and membranous structures.


2020 ◽  
Vol 36 (06) ◽  
pp. 696-702
Author(s):  
Nolan B. Seim ◽  
Enver Ozer ◽  
Sasha Valentin ◽  
Amit Agrawal ◽  
Mead VanPutten ◽  
...  

AbstractResection and reconstruction of midface involve complex ablative and reconstructive tools in head and oncology and maxillofacial prosthodontics. This region is extraordinarily important for long-term aesthetic and functional performance. From a reconstructive standpoint, this region has always been known to present challenges to a reconstructive surgeon due to the complex three-dimensional anatomy, the variable defects created, combination of the medical and dental functionalities, and the distance from reliable donor vessels for free tissue transfer. Another challenge one faces is the unique features of each individual resection defect as well as individual patient factors making each preoperative planning session and reconstruction unique. Understanding the long-term effects on speech, swallowing, and vision, one should routinely utilize a multidisciplinary approach to resection and reconstruction, including head and neck reconstructive surgeons, prosthodontists, speech language pathologists, oculoplastic surgeons, dentists, and/or craniofacial teams as indicated and with each practice pattern. With this in mind, we present our planning and reconstructive algorithm in midface reconstruction, including a dedicated focus on dental rehabilitation via custom presurgical planning.


Author(s):  
Tingting Xia ◽  
Chengfei Xu ◽  
Pengfei Dai ◽  
Xiaoyun Li ◽  
Riming Lin ◽  
...  

Three-dimensional (3D) conductive polymers are promising conductive matrices for electrode materials toward electrochemical energy storage. However, their fragile nature and weak binding forces with active materials could not guarantee long-term...


2021 ◽  
pp. 112067212110000
Author(s):  
Annabel LW Groot ◽  
Jelmer S Remmers ◽  
Roel JHM Kloos ◽  
Peerooz Saeed ◽  
Dyonne T Hartong

Purpose: Recurrent contracted sockets are complex situations where previous surgeries have failed, disabling the wear of an ocular prosthesis. A combined method of surgery and long-term fixation using custom-made, three-dimensional (3D) printed conformers is evaluated. Methods: Retrospective case series of nine patients with recurrent excessive socket contraction and inability to wear a prosthesis, caused by chemical burns ( n = 3), fireworks ( n = 3), trauma ( n = 2) and enucleation and radiotherapy at childhood due to optic nerve glioma ( n = 1) with three average previous socket surgeries (range 2–6). Treatment consisted of a buccal mucosal graft and personalized 3D-printed conformer designed to be fixated to the periosteum and tarsal plates for minimal 2 months. Primary outcome was the retention of an ocular prosthesis. Secondary outcome was the need for additional surgeries. Results: Outcomes were measured at final follow-up between 7 and 36 months postoperatively (mean 20 months). Eight cases were able to wear an ocular prosthesis after 2 months. Three cases initially treated for only the upper or only the lower fornix needed subsequent surgery for the opposite fornix for functional reasons. Two cases had later surgery for cosmetic improvement of upper eyelid position. Despite pre-existing lid abnormalities (scar, entropion, lash deficiency), cosmetic outcome was judged highly acceptable in six cases because of symmetric contour and volume, and reasonably acceptable in the remaining two. Conclusions: Buccal mucosal transplant fixated with a personalized 3D-designed conformer enables retention of a well-fitted ocular prosthesis in previously failed socket surgeries. Initial treatment of both upper and lower fornices is recommended to avoid subsequent surgeries for functional reasons.


Sign in / Sign up

Export Citation Format

Share Document