scholarly journals Test-retest Reliability of the Korean Matrix Sentence-in-noise Recognition in Sound-field Testing Condition

2021 ◽  
Vol 17 (4) ◽  
pp. 344-351
Author(s):  
Yukyeong Jung ◽  
Jae Ho Han ◽  
Seokyu Choi ◽  
Jae Hee Lee

Purpose: This study aimed to measure the test-retest reliability of the Korean Matrix sentence-in-noise test in a sound-field testing condition.Methods: Fifty-five listeners with normal hearing participated. The sound-field speech-in-noise test was administered with a front loudspeaker by presenting noise at a fixed level (65 dB SPL) while adaptively adjusting the sentence level based on the listener’s response. The speech reception thresholds (SRTs) corresponding to 50% sentence-in-noise intelligibility were obtained using speech-shaped noise (SSN), International Collegium of Rehabilitative Audiology (ICRA) noise, and International Speech Test Signal (ISTS) noise. For the test-retest reliability, each subject was tested twice in a 2-week interval. The test-retest reliabilities were judged by the intraclass correlation coefficient (ICC), the minimal detectable change (MDC) values, and Bland-Altman plots.Results: The test-retest reliabilities of the Korean Matrix sentence test were good (ICC, 0.84~0.86) across SSN, ICRA, ISTS noises. The MDC was 0.92 dB SNR for SSN and 2.83 and 2.98 dB SNR for ICRA and ISTS, indicating the random measurement error varied across the types of noise.Conclusion: The Korean Matrix sentence-in-noise test can be used as a reliable tool to assess speech-in-noise intelligibility in sound-field testing condition. Further study across various sessions would strengthen the present finding.

2011 ◽  
Vol 91 (1) ◽  
pp. 114-121 ◽  
Author(s):  
Sheau-Ling Huang ◽  
Ching-Lin Hsieh ◽  
Ruey-Meei Wu ◽  
Chun-Hwei Tai ◽  
Chin-Hsien Lin ◽  
...  

Background The minimal detectable change (MDC) is the smallest amount of difference in individual scores that represents true change (beyond random measurement error). The MDCs of the Timed “Up & Go” Test (TUG) and the Dynamic Gait Index (DGI) in people with Parkinson disease (PD) are largely unknown, limiting the interpretability of the change scores of both measures. Objective The purpose of this study was to estimate the MDCs of the TUG and the DGI in people with PD. Design This investigation was a prospective cohort study. Methods Seventy-two participants were recruited from special clinics for movement disorders at a university hospital. Their mean age was 67.5 years, and 61% were men. All participants completed the TUG and the DGI assessments twice, about 14 days apart. The MDC was calculated from the standard error of measurement. The percentage MDC (MDC%) was calculated as the MDC divided by the mean of all scores for the sample. Furthermore, the intraclass correlation coefficient was used to examine the reproducibility between testing sessions (test-retest reliability). Results The respective MDC and MDC% of the TUG were 3.5 seconds and 29.8, and those of the DGI were 2.9 points and 13.3. The test-retest reliability values for the TUG and the DGI were high; the intraclass correlation coefficients were .80 and .84, respectively. Limitations The study sample was a convenience sample, and the participants had mild to moderately severe PD. Conclusions The results showed that the TUG and the DGI have generally acceptable random measurement error and test-retest reliability. These findings should help clinicians and researchers determine whether a change in an individual patient with PD is a true change.


2019 ◽  
Vol 28 (3S) ◽  
pp. 736-741 ◽  
Author(s):  
Lisa Brown ◽  
Faheema Mahomed-Asmail ◽  
Karina C. De Sousa ◽  
De Wet Swanepoel

Purpose This study compared the speech reception thresholds (SRTs) and test–retest reliability of the smartphone digits-in-noise (DIN) test coupled to various sound-field transducers. Method Fifty normal-hearing participants (bilateral pure- tone thresholds 0.5–8kHz ≤ 15dB HL) between the ages of 18 and 25 years ( M = 20, SD = ±1.9) were recruited. The study used a repeated measure counterbalanced Latin square design to compare the SRTs of the smartphone DIN test recorded with earphones, 2 smartphone speakers, and 2 external loudspeakers in a sound booth. Test–retest reliability across sound field conditions was also determined. Results Mean SRTs across earphone and different sound field transducers ranged from −11.3 ( SD = 0.8) to −11.7 ( SD = 1.2). SRTs across the 4 different loudspeaker transducers and earphones were not significantly different ( p > .05) between test and retest sessions. Conclusion The smartphone DIN test is reliable and can be conducted using various sound field transducers in a sound booth. To allow home-based testing without earphones, with special application to aided performance for speech-in-noise testing, the smartphone DIN test should be evaluated in home environments.


2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Juan Pablo Martinez-Cano ◽  
Daniel Vernaza-Obando ◽  
Julián Chica ◽  
Andrés Mauricio Castro

Abstract Objective The aim of this study was to translate to Spanish the patellofemoral pain and osteoarthritis subscale of the knee injury and osteoarthritis outcome score (KOOS-PF) and validate this Spanish version of a disease-specific patient-reported outcome measure (PROM) for patellofemoral pain. Results The KOOS-PF was translated to Spanish and sixty patients with patellofemoral pain and/or osteoarthritis accepted to complete the questionnaire. 1-week later 58 patients answered the questions again for the test–retest reliability validation and finally 55 patients completed 1-month later for the responsiveness assessment. The Spanish version showed very good internal consistency (Cronbach’s alpha: 0.93) and test–retest reliability (intraclass correlation coefficient: 0.82). Responsiveness was confirmed, showing a strong correlation with the global rating of change (GROC) score (r 0.64). The minimal detectable change was 11.1 points, the minimal important change was 17.2 points, and there were no floor or ceiling effects for the score.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Kuan-Wei Chen ◽  
Ya-Chen Lee ◽  
Tzu-Ying Yu ◽  
Li-Jung Cheng ◽  
Chien-Yu Chao ◽  
...  

Abstract Background Fluid intelligence deficits affect executive functioning and social behaviors in patients with schizophrenia. To help clinicians manage fluid intelligence deficits, a psychometrically sound measure is needed. The purposes of this study were to examine the test–retest reliability and convergent validity of the Test of Nonverbal Intelligence-Fourth Edition (TONI-4) assessing fluid intelligence in patients with schizophrenia. Methods A total of 103 patients with stable condition were assessed with the TONI-4 twice with a 4-week interval to examine the test–retest reliability. We further used the Montreal Cognitive Assessment (MoCA) and the Tablet-Based Symbol Digit Modalities Test (T-SDMT) to examine the convergent validity of the TONI-4. Results The intra-class correlation coefficient was 0.73 for the TONI-4. The percentages of standard error of measurement and minimal detectable change for the TONI-4 were 5.1 and 14.2%, respectively. The practice effect of the TONI-4 was small (Cohen’s d = − 0.03). Convergent validity showed small to moderate significant correlations between the TONI-4 and the MoCA as well as the T-SDMT (r = 0.35, p = .011 with the T-SDMT and r = 0.61, p < .001 with the MoCA). The results demonstrated that the TONI-4 had good test–retest reliability, limited random measurement error, and a trivial practice effect. The convergent validity of the TONI-4 was good. Conclusions These findings indicate that the TONI-4 has potential to be a reliable and valid assessment of fluid intelligence in patients with schizophrenia.


2021 ◽  
Author(s):  
A Wallin ◽  
M Kierkegaard ◽  
E Franzén ◽  
S Johansson

Abstract Objective The mini-BESTest is a balance measure for assessment of the underlying physiological systems for balance control in adults. Evaluations of test–retest reliability of the mini-BESTest in larger samples of people with multiple sclerosis (MS) are lacking. The purpose of this study was to investigate test–retest reliability of the mini-BESTest total and section sum scores and individual items in people with mild to moderate overall MS disability. Methods This study used a test–retest design in a movement laboratory setting. Fifty-four people with mild to moderate overall MS disability according to the Expanded Disability Status scale (EDSS) were included, with 28 in the mild subgroup (EDSS 2.0–3.5) and 26 in the moderate subgroup (EDSS 4.0–5.5). Test–retest reliability of the mini-BESTest was evaluated by repeated measurements taken 1 week apart. Reliability and measurement error were analyzed. Results Test–retest reliability for the total scores were considered good to excellent, with intraclass correlation coefficients of .88 for the whole sample, .83 for the mild MS subgroup, and .80 for the moderate MS subgroup. Measurement errors were small, with standard error of measurement and minimal detectable change of 1.3 and 3.5, respectively, in mild MS, and 1.7 and 4.7, respectively, in moderate MS. The limits of agreement were − 3.4 and 4.6. Test–retest reliability for the section scores were fair to good or excellent; weighted kappa values ranged from .62 to .83. All items but 1 showed fair to good or excellent test–retest reliability, and percentage agreement ranged from 61% to 100%. Conclusions The mini-BESTest demonstrated good to excellent test–retest reliability and small measurement errors and is recommended for use in people with mild to moderate MS. Impact Knowledge of limits of agreement and minimal detectable change contribute to interpretability of the mini-BESTest total score. The findings of this study enhance the clinical usefulness of the test for evaluation of balance control and for designing individually customized balance training with high precision and accuracy in people with MS.


Author(s):  
Katherine L. Marks ◽  
Alessandra Verdi ◽  
Laura E. Toles ◽  
Kaila L. Stipancic ◽  
Andrew J. Ortiz ◽  
...  

Objective The purpose of this study was to examine the psychometric properties of an ecological vocal effort scale linked to a voicing task. Method Thirty-eight patients with nodules, 18 patients with muscle tension dysphonia, and 45 vocally healthy control individuals participated in a week of ambulatory voice monitoring. A global vocal status question was asked hourly throughout the day. Participants produced a vowel–consonant–vowel syllable string and rated the vocal effort needed to produce the task on a visual analog scale. Test–retest reliability was calculated for a subset using the intraclass correlation coefficient, ICC(A, 1). Construct validity was assessed by (a) comparing the weeklong vocal effort ratings between the patient and control groups and (b) comparing weeklong vocal effort ratings before and after voice rehabilitation in a subset of 25 patients. Cohen's d, the standard error of measurement ( SEM ), and the minimal detectable change (MDC) assessed sensitivity. The minimal clinically important difference (MCID) assessed responsiveness. Results Test–retest reliability was excellent, ICC(A, 1) = .96. Weeklong mean effort was statistically higher in the patients than in controls ( d = 1.62) and lower after voice rehabilitation ( d = 1.75), supporting construct validity and sensitivity. SEM was 4.14, MDC was 11.47, and MCID was 9.74. Since the MCID was within the error of the measure, we must rely upon the MDC to detect real changes in ecological vocal effort. Conclusion The ecological vocal effort scale offers a reliable, valid, and sensitive method of monitoring vocal effort changes during the daily life of individuals with and without vocal hyperfunction.


2019 ◽  
Vol 48 (Supplement_4) ◽  
pp. iv18-iv27 ◽  
Author(s):  
Kitima Rongsawad ◽  
Laddawon Worawan ◽  
Karnsiree Jirarojprapa ◽  
Sararat Kaewkham ◽  
Sarawut Khattiwong

Abstract Introduction Static postural stability is the ability to maintain the posture with minimum sway. Increasing postural sway during standing in different sensory conditions is associated with aging due to decline in sensory and motor functions. Sway area measured by using sway meter is usually simple method for assessing postural stability in elderly subjects. Like many biological measurements, sway area has an intrinsic variability that affects their test-retest reliability and responsiveness of postural stability assessment. The minimal detectable change (MDC) is ability to detect smallest change beyond measurement error that reflects a reliable change. Therefore, the MDC value could provide information of clinical relevance on postural stability. The aims of this study were to determine test-retest reliability and MDC of sway area obtained from sway meter in elderly subjects. Methods Twelve healthy elderly subjects aged 60 years and above were participated in this study. The test and retest repeatability of postural sway measurements were performed twice with a 1-hour interval. For each subject was assess postural sway using Lord’s sway meter during standing on 4 sensory conditions for 30 seconds of each condition. The test-retest reliability of sway area was calculated using intraclass correlation coefficient. The MDC for each sway area was calculated to quantify clinical relevance. Results The test-retest reliability of sway area revealed good to excellent reliability ranged from 0.85 to 0.94. Standard error of measurement (SEM) and MDC ranged from 75 to 205 mm2 and 209 to 568 mm2, respectively. Discussion and Conclusion Our findings reveal that sway area in different sensory conditions could be used in assessment of postural stability in elderly subjects. SEM and MDC of sway area increased when subjects were asked to close their eyes and on foam surface. The sway meter is a reliable tool for assessing postural stability in clinical setting.


2020 ◽  
Vol 47 (4) ◽  
pp. 479-486
Author(s):  
Yuki Kondo ◽  
Kyota Bando ◽  
Yosuke Ariake ◽  
Wakana Katsuta ◽  
Kyoko Todoroki ◽  
...  

BACKGROUND: The reliability of the evaluation of the Balance Evaluation Systems Test (BESTest) and its two abbreviated versions are confirmed for balance characteristics and reliability. However, they are not utilized in cases of spinocerebellar ataxia (SCA). OBJECTIVE: We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BESTest and its abbreviated versions in persons with mild to moderate spinocerebellar ataxia. METHODS: The BESTest was performed in 20 persons with SCA at baseline and one month later. The scores of the abbreviated version of the BESTest were determined from the BESTest scores. The interclass correlation coefficient (1,1) was used as a measure of relative reliability. Furthermore, we calculated the MDC in the BESTest and its abbreviated versions. RESULTS: The intraclass correlation coefficients (1,1) and MDC at 95% confidence intervals were 0.92, 8.7(8.1%), 0.91, 4.1(14.5%), and 0.81, 5.2(21.6%) for the Balance, Mini-Balance, and Brief-Balance Evaluation Systems Tests, respectively. CONCLUSIONS: The BESTest and its abbreviated versions had high test-retest reliability. The MDC values of the BESTest could enable clinicians and researchers to interpret changes in the balance of patients with SCA more precisely.


2016 ◽  
Vol 96 (12) ◽  
pp. 1955-1964 ◽  
Author(s):  
Cathy C. Harro ◽  
Alicia Marquis ◽  
Natasha Piper ◽  
Chris Burdis

Abstract Background Complex movement and balance impairments in people with Parkinson disease (PD) contribute to high fall risk. Comprehensive balance assessment is warranted to identify intrinsic fall risk factors and direct interventions. Objective The purpose of this study was to examine the psychometric properties of 3 balance measures of a force platform (FP) system in people with PD. Methods Forty-two community-dwelling individuals with idiopathic PD completed the testing protocol. Test-retest reliability was assessed for the Limits of Stability Test (LOS), Motor Control Test (MCT), and Sensory Organization Test (SOT). Intraclass correlation coefficients (ICC [2,1]) were calculated to determine test-retest reliability and minimal detectable change. Validity was assessed by comparing the FP measures with criterion gait and balance measures using Pearson product moment correlations. Multiple regression analyses examined the contribution of PD characteristics to FP measures. Results All primary FP variables demonstrated excellent test-retest reliability (ICC=.78–.92). The SOT and LOS demonstrated fair to good correlations with criterion measures, whereas the MCT had fair correlations to balance measures only. Both SOT composite equilibrium and MCT average latency were moderately associated with disease severity. Limitations This study's sample had a relatively small number of participants with a positive fall history, which may limit the generalizability of the findings. Conclusions This study's findings provide support that FP measures are reliable and valid tests of balance impairment in people with PD. Disease severity was significantly associated with SOT and MCT measures, perhaps reflecting that these tests are meaningful indicators of decline in postural control with disease progression. Force platform measures may provide valuable quantitative information about underlying balance impairments in people with PD to guide therapeutic interventions for fall risk reduction.


2021 ◽  
pp. 1-4
Author(s):  
Jamon Couch ◽  
Marc Sayers ◽  
Tania Pizzari

Context: An imbalance between shoulder internal rotation (IR) and external rotation (ER) strength in athletes is proposed to increase the risk of sustaining a shoulder injury. Hand-held (HHD) and externally fixed dynamometry are reliable forms of assessing shoulder IR and ER strength. A new externally fixed device with an attachable fixed upper-limb mold (The ForceFrame) exists; however, its reliability in measuring shoulder strength is yet to be investigated. Objective: To determine the test–retest reliability of the ForceFrame, with and without the fixed upper-limb mold, in the assessment of shoulder IR and ER strength, as compared with HHD. Design: Test–retest reliability study. Setting: Laboratory, clinical. Participants: Twenty-two healthy and active individuals were recruited from the university community and a private physiotherapy practice. Main Outcome Measures: Maximal isometric shoulder IR and ER strength was measured using the ForceFrame and traditional HHD in neutral and at 90° shoulder abduction. Mean (SD) strength measures were calculated. Test–retest reliability was analyzed using intraclass correlation coefficients (3, 1). The SEM and minimal detectable change were calculated. Results: Good to excellent test–retest reliability was found for all shoulder strength tests across Hand-held dynamometry (HHD) and externally fixed dynamometry (EFD) are reliable forms (intraclass correlation coefficients [3, 1] = .854–.916). The minimal detectable changes ranged between 25.61 and 41.84 N across tests. Test–retest reliability was not affected by the dynamometer or testing position. Conclusions: The results from this study indicate that both the ForceFrame and HHD are suitable for measuring shoulder strength in clinical practice. The use of the fixed upper-limb mold with the ForceFrame does not improve reliability.


Sign in / Sign up

Export Citation Format

Share Document