signal quality
Recently Published Documents


TOTAL DOCUMENTS

987
(FIVE YEARS 369)

H-INDEX

35
(FIVE YEARS 9)

2022 ◽  
Vol 12 ◽  
Author(s):  
Silvia Seoni ◽  
Simeon Beeckman ◽  
Yanlu Li ◽  
Soren Aasmul ◽  
Umberto Morbiducci ◽  
...  

Background: Laser-Doppler Vibrometry (LDV) is a laser-based technique that allows measuring the motion of moving targets with high spatial and temporal resolution. To demonstrate its use for the measurement of carotid-femoral pulse wave velocity, a prototype system was employed in a clinical feasibility study. Data were acquired for analysis without prior quality control. Real-time application, however, will require a real-time assessment of signal quality. In this study, we (1) use template matching and matrix profile for assessing the quality of these previously acquired signals; (2) analyze the nature and achievable quality of acquired signals at the carotid and femoral measuring site; (3) explore models for automated classification of signal quality.Methods: Laser-Doppler Vibrometry data were acquired in 100 subjects (50M/50F) and consisted of 4–5 sequences of 20-s recordings of skin displacement, differentiated two times to yield acceleration. Each recording consisted of data from 12 laser beams, yielding 410 carotid-femoral and 407 carotid-carotid recordings. Data quality was visually assessed on a 1–5 scale, and a subset of best quality data was used to construct an acceleration template for both measuring sites. The time-varying cross-correlation of the acceleration signals with the template was computed. A quality metric constructed on several features of this template matching was derived. Next, the matrix-profile technique was applied to identify recurring features in the measured time series and derived a similar quality metric. The statistical distribution of the metrics, and their correlates with basic clinical data were assessed. Finally, logistic-regression-based classifiers were developed and their ability to automatically classify LDV-signal quality was assessed.Results: Automated quality metrics correlated well with visual scores. Signal quality was negatively correlated with BMI for femoral recordings but not for carotid recordings. Logistic regression models based on both methods yielded an accuracy of minimally 80% for our carotid and femoral recording data, reaching 87% for the femoral data.Conclusion: Both template matching and matrix profile were found suitable methods for automated grading of LDV signal quality and were able to generate a quality metric that was on par with the signal quality assessment of the expert. The classifiers, developed with both quality metrics, showed their potential for future real-time implementation.


2022 ◽  
Vol 12 ◽  
Author(s):  
Eemu-Samuli Väliaho ◽  
Jukka A. Lipponen ◽  
Pekka Kuoppa ◽  
Tero J. Martikainen ◽  
Helena Jäntti ◽  
...  

Aim: Atrial fibrillation (AF) detection is challenging because it is often asymptomatic and paroxysmal. We evaluated continuous photoplethysmogram (PPG) for signal quality and detection of AF.Methods: PPGs were recorded using a wrist-band device in 173 patients (76 AF, 97 sinus rhythm, SR) for 24 h. Simultaneously recorded 3-lead ambulatory ECG served as control. The recordings were split into 10-, 20-, 30-, and 60-min time-frames. The sensitivity, specificity, and F1-score of AF detection were evaluated for each time-frame. AF alarms were generated to simulate continuous AF monitoring. Sensitivities, specificities, and positive predictive values (PPVs) of the alarms were evaluated. User experiences of PPG and ECG recordings were assessed. The study was registered in the Clinical Trials database (NCT03507335).Results: The quality of PPG signal was better during night-time than in daytime (67.3 ± 22.4% vs. 30.5 ± 19.4%, p < 0.001). The 30-min time-frame yielded the highest F1-score (0.9536), identifying AF correctly in 72/76 AF patients (sensitivity 94.7%), only 3/97 SR patients receiving a false AF diagnosis (specificity 96.9%). The sensitivity and PPV of the simulated AF alarms were 78.2 and 97.2% at night, and 49.3 and 97.0% during the daytime. 82% of patients were willing to use the device at home.Conclusion: PPG wrist-band provided reliable AF identification both during daytime and night-time. The PPG data’s quality was better at night. The positive user experience suggests that wearable PPG devices could be feasible for continuous rhythm monitoring.


2022 ◽  
pp. 636-644
Author(s):  
Shreem Ghosh ◽  
Arijit Ghosh

In any electrical or electronic systems, unwanted signals known as noise signals are encountered which interact with the true signal and thus affecting signal quality. Noise may enter into a device or system in many forms and have a different order of impacts. Prevention and elimination of noise had attained paramount importance to ensure signal fidelity. This chapter presents a comprehensive analysis on elimination of noise by electronic grounding of instrumentation and automation systems as well as various engineering considerations for the same.


2021 ◽  
Vol 7 (4) ◽  
pp. 138-149
Author(s):  
S. Myshyanov

The article presents the results of measurements of the parameters of the digital radio broadcasting DRM signal quality in the experimental zone of St. Petersburg in order to determine the influence of the transmission modes laid down in the DRM standard on the size of the service area.


2021 ◽  
Vol 3 (2) ◽  
pp. 53-66
Author(s):  
Leboli Thamae ◽  
Itumeleng Potsanyane ◽  
Mpho Mokhetsengoane

This article presents the computer simulation and field test measurement results on Channel 29 for the preliminary performance evaluation and verification of the newly-installed Lesotho digital terrestrial television network based on DVB-T2 standard following the guidelines and techniques specified by the ITU-R BT.2035-2. It evaluates, at predetermined outdoor locations for fixed and mobile reception, parameters such as received signal strength, signal quality, bit-error rate (BER) and threshold-of-visibility (ToV) together with TV signal decoding (observation of screen artefacts) for quasi error-free reception. The results indicate that at over 97% of the test sites/points at the university town of Roma, the main Berea Plateau transmitter from the capital city (Maseru) broadcasts digital television service with enough signal level and quality to be properly decoded. The measured signal strength threshold ranges above -50 dBm for good reception, -64 dBm to -50 dBm for acceptable reception and -69 dBm to -64 dBm for poor reception. With the noise floor at about -73 dBm, the minimum required C/N of around 23 dB for good reception and about 4 dB for ToV have been recorded. The relative values of minimum required respective signal strength and signal quality for ToV obtained from the set-top box are 33% and 18% for stationary reception, while they give 37% and 20% for mobile reception.


2021 ◽  
Vol 8 ◽  
Author(s):  
Meseret N. Teferra ◽  
David A. Hobbs ◽  
Robyn A. Clark ◽  
Karen J. Reynolds

Background: With cardiovascular disease continuing to be the leading cause of death and the primary reason for hospitalization worldwide, there is an increased burden on healthcare facilities. Electronic-textile (e-textile)-based cardiac monitoring offers a viable option to allow cardiac rehabilitation programs to be conducted outside of the hospital.Objectives: This study aimed to determine whether signals produced by an e-textile ECG monitor with textile electrodes in an EASI configuration are of sufficient quality to be used for cardiac monitoring. Specific objectives were to investigate the effect of the textile electrode characteristics, placement, and condition on signal quality, and finally to compare results to a reference ECG obtained from a current clinical standard the Holter monitor.Methods: ECGs during different body movements (yawning, deep-breathing, coughing, sideways, and up movement) and activities of daily living (sitting, sitting/standing from a chair, and climbing stairs) were collected from a baseline standard of normal healthy adult male using a novel e-textile ECG and a reference Holter monitor. Each movement or activity was recorded for 5 min with 2-min intervals between each recording. Three different textile area electrodes (40, 60, and 70 mm2) and electrode thicknesses (3, 5, and 10 mm) were considered in the experiment. The effect of electrode placement within the EASI configuration was also studied. Different signal quality parameters, including signal to noise ratio, approximate entropy, baseline power signal quality index, and QRS duration and QT intervals, were used to evaluate the accuracy and reliability of the textile-based ECG monitor.Results: The overall signal quality from the 70 mm2 textile electrodes was higher compared to the smaller area electrodes. Results showed that the ECGs from 3 and 5 mm textile electrodes showed good quality. Regarding location, placing the “A” and “I” electrodes on the left and right anterior axillary points, respectively, showed higher signal quality compared to the standard EASI electrode placement. Wet textile electrodes showed better signal quality compared to their dry counterparts. When compared to the traditional Holter monitor, there was no significant difference in signal quality, which indicated textile monitoring was as good as current clinical standards (non-inferior).Conclusion: The e-textile EASI ECG monitor could be a viable option for real-time monitoring of cardiac activities. A clinical trial in a larger sample is recommended to validate the results in a clinical population.


Author(s):  
Karrar Shakir Muttair ◽  
Ali Z. Ghazi Zahid ◽  
Oras A. Shareef Al-Ani ◽  
Ahmed Mohammed Q. AL-Asadi ◽  
Mahmood F. Mosleh

With the development of various wireless communication networks, Wi-Fi Router positioning and deployment systems have become widely popular in recent years to improve coverage in various environments. In this paper, we present an appropriate mechanism for defining the deployment of Wi-Fi Routers to improve coverage in the Oxford Languages Institute (OLI) environment. In addition, the institute's environment was simulated using the Wireless InSite (WI) Package. In this work, two types of Wi-Fi Routers are used. The first is the TP-Link, while the second is the Rocket. These two devices operate at 2.4 and 5 GHz frequencies. There are two objectives in this work. The first aim is to determine the best location to cover the simulated scene environment in a better way. The second aim is to compare Wi-Fi Routers to find out which Wi-Fi Router is better and find out how many Wi-Fi Routers we need to cover the institute's environment. The comparison between Wi-Fi Routers was based on basic parameters to measure the performance of wireless networks, the most important of which are Coverage Rate (CR) Percentage, Signal Quality Rate (SQR), and Received Power Rate (RPR). According to the results that were shown on the Graphical User Interface (GUI) using MATLAB Software. We noticed that the CR, SQR, and RPR of the Rocket are 83.9080%, 97.0082%, and -35.2337 dBm respectively, and these results are better than the results provided by the TP-Link, as it gave the CR, SQR, and RPR are 32.1839%, 77.8690%, and -58.1685 dBm, respectively. Finally, we conclude that CR using the Rocket is good and we need one device to cover the institute’s environment. While CR using the TP-Link is bad and we need five devices to reach the coverage provided by the Rocket because the Rocket has high transmitted power and gain capacity.


2021 ◽  
Vol 3 ◽  
Author(s):  
Jochen Kempfle ◽  
Kristof Van Laerhoven

As depth cameras have gotten smaller, more affordable, and more precise, they have also emerged as a promising sensor in ubiquitous systems, particularly for detecting objects, scenes, and persons. This article sets out to systematically evaluate how suitable depth data can be for picking up users’ respiration, from small distance changes across the torso over time. We contribute a large public dataset of depth data over time from 19 persons taken in a large variety of circumstances. On this data, we evaluate and compare different state-of-the-art methods and show that their individual performance significantly depends on a range of conditions and parameters. We investigate the influence of the observed torso region (e.g., the chest), the user posture and activity, the distance to the depth camera, the respiratory rate, the gender, and user specific peculiarities. Best results hereby are obtained from the chest whereas the abdomen is least suited for detecting the user’s breathing. In terms of accuracy and signal quality, the largest differences are observed on different user postures and activities. All methods can maintain a mean accuracy of above 92% when users are sitting, but half of the observed methods only achieve a mean accuracy of 51% while standing. When users are standing and additionally move their arms in front of their upper body, mean accuracy values between the worst and best performing methods range from 21 to 87%. Increasing the distance to the depth camera furthermore results in lower signal quality and decreased accuracy on all methods. Optimal results can be obtained at distances of 1–2 m. Different users have been found to deliver varying qualities of breathing signals. Causes range from clothing, over long hair, to movement. Other parameters have shown to play a minor role in the detection of users’ breathing.