The Arab Journal of Interventional Radiology
Latest Publications


TOTAL DOCUMENTS

130
(FIVE YEARS 73)

H-INDEX

2
(FIVE YEARS 2)

Published By Medknow Publications

2542-7075

Author(s):  
Mizuki Ozawa ◽  
Miyuki Sone ◽  
Yasuaki Arai ◽  
Shunsuke Sugawara ◽  
Chihiro Itou ◽  
...  

Abstract Purpose The aim of the study is to evaluate the feasibility, safety, and efficacy of the trans-colostomy placement of a button gastrostomy tube for patients with malignant bowel obstruction due to peritoneal carcinomatosis. Material and Methods Data from seven consecutive patients who presented with malignant bowel obstruction due to peritoneal carcinomatosis involving the colostomy site and underwent trans-colostomy button gastrostomy tube placement between 2013 and 2020 were retrospectively reviewed. We assessed technical and clinical success rate, procedure time, duration of improvement, and complication rate. Results The technical success rate of the trans-colostomy button gastrostomy tube placement was 100%, and average procedure time was 25 minutes. Clinical symptoms of malignant bowel obstruction resolved in four out of seven (57%) patients. Average duration of improvement in the four patients with clinical success was 170.8 days. There were no complications associated with the procedure. Conclusion Trans-colostomy button gastrostomy tube placement might be a safe and feasible treatment option for patients with malignant bowel obstruction due to peritoneal carcinomatosis.


Author(s):  
Rengarajan Rajagopal ◽  
Smily Sharma ◽  
Meenu Bagarhatta ◽  
Sarbesh Tiwari ◽  
Rajeev Bagarhatta

AbstractPseudoaneurysms of extracranial internal carotid artery (ICA) are rare in children. Main causes include trauma, iatrogenic causes, and neck space infection. Prompt diagnosis and management is vital, in view of life-threatening complications like fatal airway hemorrhage and stroke. Endovascular management has currently become the preferred treatment strategy due to its minimally invasive nature and lower complication rates. We report a rare case of mycotic pseudoaneurysm of extracranial ICA in a 4-year-old child as a complication of neck space infection, which was successfully managed with endovascular parent artery occlusion.


Author(s):  
I. Aljediea ◽  
M. Alshehri ◽  
K. Alenazi ◽  
A. Memesh ◽  
M. Fleet

Abstract Purpose We conducted this study to review our local experience of performing peripherally inserted central catheters by interventional radiology technologists. Materials and Methods This is a retrospective study of peripherally inserted central catheters performed by interventional radiology technologists. These procedures were performed using ultrasound guidance for venous puncture and fluoroscopy or electrocardiography guidance followed by chest X-ray to confirm tip location. Results We reviewed all peripherally inserted central catheters performed in interventional radiology between May 2017 and July 2020. The review process included the success rate, number of venous puncture attempts, method of guidance, procedure time, fluoroscopy time, catheter duration to removal, and complications. Conclusion Interventional radiology technologists can perform peripherally inserted central catheters safely with high success rate. Extending interventional radiology technologists' role to perform peripherally inserted central catheters allow interventional radiologists to do more complex procedures. This enhances the workflow, increases the interventional radiology team efficiency, and improves the waiting time.


Author(s):  
Mohamed Shaker ◽  
Essam Hashem ◽  
Ahmed Abdelrahman ◽  
Ahmed Okba

Abstract Context Prostatic artery embolization (PAE) has been established as a safe and effective treatment option for symptomatic benign prostatic hyperplasia (BPH). Thorough knowledge of detailed prostatic artery (PA) anatomy is essential. Aims The aim of this study was to provide a pictorial review of PA anatomy and prevalence of related anatomical variants, in addition to other anatomical and radiation dose considerations. Settings and Design Case series and review of literature. Materials and Methods We performed PAE for 210 patients from November 2015 to November 2020 under local anesthesia only. Anatomy, procedure duration, fluoroscopy time, radiation dose, technical success, and complications were analyzed. Statistical Analysis Used Descriptive statistics were analyzed using Microsoft Excel software. Results A total of 210 patients (420 sides) were analyzed. Double arterial supply on the same side was noted in 12 patients (5.7%). In 10 patients (4.7%), only a unilateral PA was identified. In two patients (0.9%), no PA could be identified. Frequencies of PA origins were calculated. Penile, rectal, and vesical anastomoses were identified with 79 (18.8%), 54 (12.9%), and 41 (9.8%) of PAs, respectively. Median skin radiation dose, procedure time, and fluoroscopy time were 505 mGy, 73 and 38 minutes, respectively. Complications occurred in nine patients (4.3%), none of them was major. Conclusions Knowledge of PA anatomy is essential when treating BPH by PAE for optimum results. There is no enough evidence to support routine use of preoperative computed tomography angiography and intraoperative cone-beam computed tomography as means of improving safety or efficacy.


Author(s):  
Yasuyuki Onishi ◽  
Yasuaki Arai ◽  
Miyuki Sone ◽  
Shunsuke Sugawara ◽  
Chihiro Itou ◽  
...  

Abstract Purpose The purpose was to assess the diagnostic accuracy and safety of percutaneous transhepatic biopsy for extrahepatic lesions. Materials and Methods Between January 2008 and December 2019, 26 patients (17 men and 9 women; median age, 60 years) underwent percutaneous transhepatic needle biopsy for extrahepatic lesions at our institution. Transhepatic biopsy was deemed appropriate compared with other biopsy routes or methods (i.e., endoscopic or surgical). The lesions were in the porta hepatis (n = 9), retroperitoneum (n = 6), right adrenal gland (n = 4), right kidney (n = 3), lesser omentum (n = 2), duodenum (n = 1), pleura (n = 1), and inferior vena cava (n = 1). The median maximal diameter of the lesions was 45.5 mm (range, 18–148 mm). Core-needle biopsy was performed in all patients. Eighteen-gauge and 21-G needles were used in 25 and one patient, respectively. Ultrasound was used for biopsy in 21 patients, and CT fluoroscopy was used in five patients. Postbiopsy tract embolization was performed in three patients. Technical success and diagnostic accuracy of the biopsy were evaluated. Complications were recorded using the systemic inflammation response (SIR) criteria. Results The pathological results of biopsy were carcinoma (n = 10), lymphoma (n = 9), and other diagnoses (n = 7). Technical success was obtained in all patients. The accurate diagnosis was achieved in 24 of the 26 patients (92.3%). A major complication, a bladder tamponade, was observed in one patient (3.8%) after biopsy of a right kidney lesion. A hematoma caused by iatrogenic renal injury likely obstructed the bladder outlet. Minor complications were observed in three patients (11.5%). Conclusions Percutaneous transhepatic biopsy for extrahepatic lesions is feasible with acceptable safety.


Author(s):  
Chihiro Itou ◽  
Yasuaki Arai ◽  
Miyuki Sone ◽  
Shunsuke Sugawara

AbstractThermal injury to the surrounding hollow organs should be avoided during thermal ablation therapy. Although this type of injury is rare, severe complications, such as perforation or stricture, have been reported. Despite the development of various adjunctive thermoprotection techniques, there are a few reports of their use for protecting the esophagus during liver ablation therapy. Endoluminal irrigation is a well-known technique for protecting hollow organs, such as the biliary tract, renal pelvis, ureter, and rectum; however, it is used infrequently for avoiding thermal injury to the esophagus. There may be hesitation in treating juxtaesophageal liver tumors with conventional ultrasound-guided ablation because the location restricts the ultrasonic window due to the poor visibility. We successfully treated two consecutive cases of juxtaesophageal liver tumor with computed tomography-guided ablation by applying endoluminal irrigation and cooling via a 12-French nasal feeding tube placed in the lower esophagus.


Author(s):  
Salha Al Bahkali ◽  
Ali Al Harbi ◽  
Fatimah Kamili ◽  
Ibrahim Al Rashidi

Abstract Context Lack of awareness among the students in the medical field is the greatest challenge to overcome in the emergence of contemporary interventional radiology (IR). Objectives We aimed to conduct a survey among medical students of Jazan University to explore their knowledge about IR, interest in IR as a future career, and preferred methods of training in IR. Materials and Methods This was a cross-sectional, self-directed questionnaire study. The target population was all medical students at Jazan University. Surveys were sent to 600 students. The questionnaire consisted of 11 closed and open-ended questions. Statistical Analysis We calculated the size of the sample using the Raosoft Sample Size Calculator Web site. Data analysis was performed using SPSS statistics. Results A total of 270 students responded (45%); more than half of the respondents (58.5%) were in the preclinical stage, while the rest were in the clinical stage. About 62.5% of clinical students and 66.4% preclinical students reported that their perception regarding the terminology of IR was good or excellent. Regarding the identification of interventional radiologists, 50.9% from the clinical students thought them to be radiologists and 50% from preclinical students also identified them as such.About 29.5% from the clinical students and 27.8% from the preclinical students thought them special surgeons, and 31.3% clinical students compared with 30.4% preclinical students believed they are vascular surgeons working with X-rays. About 19.6% clinical students compared with 17.7% preclinical students said they are general surgeons working with X-rays, and 48.2% clinical students compared with 45.6% preclinical students said they are special radiologists who work with percutaneous techniques. There was a significant difference (p = 0.041) in the responses between preclinical and clinical students regarding knowledge about what this medical specialty does. About 60.8% of clinical students reported that their knowledge and information regarding IR are efficient in comparison to 39.2% of preclinical students. Conclusion This study demonstrated that the basic knowledge among Jazan medical students is poor. About half of the respondents were clinical students who understood the radiology specialty, compared with one-third of preclinical students. This could impact the student’s decision toward IR as a future career.


Author(s):  
Mohammed Aljarie ◽  
Mohammed Alahmari ◽  
Mohammad Arabi

Abstract Objective The aim of this study was to assess the safety and effectiveness of the central venous angioplasty in patients with central venous occlusion and cardiac implantable electronic device (CIED) without lead extraction. Materials and Methods A retrospective study was used to evaluate the effectiveness of 37 central venous angioplasty procedure for 15 patients with CIED without lead extraction. Results Technical success was achieved in 97% (n = 36/37) and clinical success was achieved in 89% (33/37) of the procedures. One procedure failed recanalization of chronic total occlusion of the left subclavian vein, and the patient required fistula embolization due to severe arm swelling. Another procedure failed initially to recanalize long-segment occlusion involving the right subclavian vein/brachiocephalic vein and superior vena cava in a patient with a history of Hickman line and left-sided CIED. This was successfully recanalized and angioplastied on a subsequent session. No lead fracture or dislodgment was documented in any procedure. No procedure-related complication was documented within 2 weeks after the angioplasty. Six-month primary patency was achieved in 62% (23/37) of the procedures. Ten patients (66%) required an average of 1.4 reinterventions (range: 1–4 interventions) during the follow-up time with mean time to reintervention of 318 days (5–1,380 days). Two patients required early reinterventions within 10 days due to catheter dysfunction. Conclusion Findings of this study support the existing evidence on the safety and effectiveness of balloon angioplasty without lead extraction.


Sign in / Sign up

Export Citation Format

Share Document