Self locking tension band technique in transverse patellar fractures

1997 ◽  
Vol 20 (6) ◽  
pp. 357-358 ◽  
Author(s):  
A. K. Us ◽  
H. Kinik
2016 ◽  
Vol 22 ◽  
pp. 2736-2741 ◽  
Author(s):  
Zichao Xue ◽  
Hui Qin ◽  
Haoliang Ding ◽  
Haitao Xu ◽  
Zhiquan An

2020 ◽  
Vol 11 (06) ◽  
pp. 127-132
Author(s):  
Yogesh S. Salphale ◽  
Nitin Kimmatkar ◽  
Hrishikesh R. Badve

2020 ◽  
Vol 6 (1) ◽  
pp. 207-211
Author(s):  
T Naveen Babu ◽  
M Bhavyachand ◽  
K Deepak ◽  
SM Venugopal

2013 ◽  
Vol 95 (7) ◽  
pp. 653-659 ◽  
Author(s):  
C. Max Hoshino ◽  
Wesley Tran ◽  
John V. Tiberi ◽  
Mary Helen Black ◽  
Bonnie H. Li ◽  
...  

2017 ◽  
Vol 31 (2) ◽  
pp. e66-e72 ◽  
Author(s):  
Dustin S. Hambright ◽  
Kempland C. Walley ◽  
Amber Hall ◽  
Paul T. Appleton ◽  
Edward K. Rodriguez

2019 ◽  
Vol 27 (3) ◽  
pp. 230949901987401
Author(s):  
Fasheng Wang ◽  
Tianyi David Luo ◽  
Chunyong Chen ◽  
Yun Xie ◽  
Zhangxiong Lin ◽  
...  

Purpose: The purpose of this study was to assess the outcomes in a series of patients, who underwent cerclage and figure-of-eight tension band wiring using a single titanium cable for comminuted patellar fractures. Methods: We describe a modified tension band technique using a single titanium cable to create an ellipsoidal cap structure that combines the circumferential and figure-of-eight wrapping in the fixation of closed Association for the Study of Internal Fixation/Orthopaedic Trauma Association 34C2 and 34C3 patellar fractures. We retrospectively reviewed 25 patients (16 males and 9 females, mean age 54 years) who underwent the described fixation technique between 2015 and 2017. Postoperative function was evaluated using the Böstman score. Results: At the mean follow-up of 25 months (range 17–39 months), the mean Böstman score was 27.3 ± 2.6 points (range 23–30). Eighteen patients (72%) had excellent results (score ≥28); seven patients (28%) had good results (score 20–27); and no patients had an unsatisfactory result (score < 20). All surgical incisions healed without major wound complications. Two patients reported minor complications (soft tissue irritation, cellulitis). No patients demonstrated loss of reduction or implant failure during the follow-up period. Conclusion: The modified anterior ellipsoidal cap tension band using a single titanium cable created an effective tension band structure in the treatment of comminuted patella fractures. It is a simple operative technique that produced a stable fixation construct, which allowed early functional rehabilitation and weight-bearing with a high rate of excellent outcomes at 2 years after surgery.


Sign in / Sign up

Export Citation Format

Share Document