Development of the peritoneal cavity, gastrointestinal tract and its adnexae

2008 ◽  
pp. 1203-1223
2011 ◽  
Vol 96 (2) ◽  
pp. 148-152 ◽  
Author(s):  
Tamuro Hayama ◽  
Soichiro Ishihara ◽  
Norihito Yamazaki ◽  
Takuya Akahane ◽  
Ryu Shimada ◽  
...  

Abstract One rare complication of a ventriculoperitoneal (VP) shunt is perforation of the gastrointestinal tract by the catheter. We report a case in which the catheter severed spontaneously inside the peritoneal cavity, creating a communication between the intestinal tract and the peritoneal cavity. The patient was a 41-year-old man who presented with a VP shunt catheter protruding from the anus. Computed tomography showed that the VP shunt catheter, which had been put in place 25 years earlier, had severed spontaneously. The distal end had then perforated and entered the intestinal tract. The patient was hospitalized and emergency surgery was performed to repair the intestinal tract perforation caused by the end of the VP shunt catheter. Laparotomy revealed that the catheter had perforated the sigmoid colon. The VP shunt catheter was removed, and the perforation in the intestinal tract was closed by suturing. The patient was discharged on postoperative day 20.