Late Cardiac Perforation After Percutaneous Closure of an Atrial Septal Defect Using an Amplatzer Device

2007 ◽  
Vol 60 (4) ◽  
pp. 451-453
Author(s):  
Marta Ruiz Lera ◽  
José M. de la Torre-Hernández ◽  
Javier Zueco ◽  
J. Francisco Nistal
2013 ◽  
Vol 23 (2) ◽  
pp. 202-205 ◽  
Author(s):  
Mohammed Omar Galal ◽  
Muhammad Arif Khan ◽  
Milad El-Segaier

2014 ◽  
Vol 55 (5) ◽  
pp. 441
Author(s):  
KelechiE Okonta ◽  
EmmanuelO Ocheli ◽  
FrancisU Iregbu

Author(s):  
Anna Kostopoulou ◽  
Epameinontas Fountas ◽  
Olga Karapanagiotou ◽  
Stamatis Kyrzopoulos

Abstract Background Inappropriate shocks have been reported in approximately 1/3 of patients with implantable cardiac defibrillators (ICDs). We report an unusual case of inappropriate ICD shocks due to atrial fibrillation (AF) caused by a missed atrial septal defect (ASD) in a patient with a modified Bentall procedure. Case summary A 67-year-old Caucasian male, with an ICD and a history of a modified Bentall procedure 24 years ago, reported to our outpatient clinic with recurrent inappropriate ICD shocks due to episodes of fast AF. The transthoracic echocardiographic exam revealed 2 large aneurysms at the ostia of the coronary arteries. We performed further evaluation with transesophageal echocardiogram (TOE) and computed tomography (CT) angiography. The aneurysms measured on CT were 3.14*2.29 cm on the right ostium and 1.9*0.99 cm on the left. A large secundum-type atrial septal defect (ASD) of 1.5 cm was revealed that was missed in all previous echocardiographic studies. The therapeutic options of surgical closure of the ASD and repair of the aneurysms or a more conservative approach with percutaneous closure of the ASD and closer follow-up were discussed with the patient. The patient declined the surgical option due to high complication risk, and closure of the ASD with an Amplatzer device was performed 3 months later. A 3 -year Follow-up was uneventful. Conclusion It is of major importance to comprehensively and thoroughly assess patients before and after a surgical intervention to not miss other treatable conditions preoperatively and complications in the postoperative period.


Author(s):  
Igor Ya Motus ◽  
Alexander V Bazhenov ◽  
Rauf T Basyrov ◽  
Anna S Tsvirenko

Abstract OBJECTIVES A bronchopleural fistula after pneumonectomy is a relatively rare but very serious complication. The development of endoscopic methods of treatment opens a new page in treating this condition. The goal of this paper was to confirm that the atrial septal defect Amplatzer device can be used for bronchopleural fistula closure in properly selected patients. METHODS A retrospective study of 13 patients with bronchopleural fistula after pneumonectomy was performed. There were 11 men and 2 women aged 26–70 years. Right-sided fistulas occurred in 10 patients and left-sided fistulas occurred in 3. The underlying disease was lung cancer in 7 patients and pulmonary tuberculosis in 6. Video-assisted thoracoscopic surgery (N = 7) and open-window thoracostomy (N = 6) were used to treat the empyema. To treat occlusion of the bronchial fistulas, we used Amplatzer atrial septal defect occluders originally intended for closure of ventricular and interatrial septal defects. The occluder was inserted from the bronchus by flexible bronchoscopy with the patient under local anaesthesia, with the help of video-assisted thoracoscopy or through a window thoracostomy from the pleural cavity. RESULTS We noted 3 complications after the procedure. In 2 patients, displacement of the occluders required re-installation in 1 patient and latissimus dorsi muscle coverage in the other. In the third patient, the occluder became dislodged during severe exacerbation of tuberculosis that occurred after the patient violated the treatment regimen. She died of tuberculosis 6 months after the occluder was inserted. The course in the remaining 10 patients was uneventful. CONCLUSIONS Our experience suggests that the use of an atrial septal defect occluder for the treatment of a bronchial fistula after pneumonectomy is a reliable option.