Endoscopic ultrasound-guided fine-needle aspiration and fine-needle biopsy for solid lesions: Does a “belt and suspenders” approach add value?

Endoscopy ◽  
2019 ◽  
Vol 52 (01) ◽  
pp. 9-10
Author(s):  
Douglas G. Adler
2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Lachlan R. Ayres ◽  
Elizabeth K. Kmiotek ◽  
Eric Lam ◽  
Jennifer J. Telford

Background and Aims. Endoscopic ultrasound (EUS) guided fine-needle aspiration (FNA) is the method of choice for sampling pancreatic lesions. This study compares the diagnostic accuracy and safety of FNB using a novel core needle to FNA in solid pancreatic lesions. Methods. A retrospective review of patients in whom EUS FNA or FNB was performed for solid pancreatic lesions was conducted. Diagnostic performance was calculated based upon a dual classification system: classification 1, only malignant pathology considered a true positive, versus classification 2, atypical, suspicious, and malignant pathology considered a true positive. Results. 43 patients underwent FNB compared with 51 FNA. Using classification 1, sensitivity was 74.0% versus 80.0%, specificity 100% versus 100%, and diagnostic accuracy 77.0% versus 80.0% for FNB versus FNA, respectively (all p>0.05). Using classification 2, sensitivity was 97% versus 94.0%, specificity 100% versus 100%, and diagnostic accuracy 98.0% versus 94.0% for FNB versus FNA, respectively (all p>0.05). FNB required significantly fewer needle passes (median = 2) compared to FNA (median = 3; p<0.001). Adverse events occurred in two (4.5%) FNB patients compared with none in the FNA group (p>0.05). Conclusion. FNA and FNB have comparable sensitivity and diagnostic accuracy. FNB required fewer passes.


2020 ◽  
Vol 91 (6) ◽  
pp. AB317-AB318
Author(s):  
Diogo T. de Moura ◽  
Thomas R. McCarty ◽  
Pichamol Jirapinyo ◽  
Igor B. Ribeiro ◽  
Galileu F. Farias ◽  
...  

2019 ◽  
Vol 07 (10) ◽  
pp. E1281-E1287 ◽  
Author(s):  
John S Leeds ◽  
Manu K. Nayar ◽  
Noor L.H. Bekkali ◽  
Colin H. Wilson ◽  
Sarah J. Johnson ◽  
...  

Abstract Background and study aims Pancreatic neuroendocrine tumors (PanNETs) outcomes are dependent upon grading by Ki67. This study compared endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) to fine-needle aspiration (FNA) in assessing PanNETs. Patients and methods All pancreatic histology for PanNET between January 2009 and June 2017 was included if EUS sampling was performed prior to surgical resection. Ki67 and grade from FNA and FNB samples was compared to surgical histology using correlation coefficient and kappa values. Subgroup analysis was performed for purely solid lesions, lesions < 2 cm and FNB needle type. Results One hundred sixity-four patients had PanNET of which 57 underwent surgical resection. Thirty-five lesions underwent FNA and 26 FNB (4 had both) confirming PanNET. 23/ of 35 FNA samples reported Ki67/grading compared to all 26 FNB samples (P = 0.0006). Compared to surgical histology, Ki67 on FNA correlated poorly overall (r = –0.08), in solid lesions (r = –0.102) and lesions < 2 cm (r = –0.149) whereas FNB correlated moderately overall (r = 0.65), in solid lesions (r = 0.64) and lesions < 2 cm (r = 0.61). Tumor grade showed poor agreement (kappa) with FNA overall (0.026), in solid lesions (0.044) and lesions < 2 cm (0.00) whereas FNB showed moderate-good agreement overall (0.474), in solid lesions (0.58) and lesions < 2 cm (0.745). Fork-tip FNB needles Ki67 showed strong correlation with surgical histology (r = 0.788) compared to reverse bevel FNB needles (r = 0.521). Both FNB needles showed moderate agreement with tumor grade. Conclusion FNB samples were significantly more likely than FNA to provide adequate material for Ki67/grading and showed a closer match to surgical histology. FNB needle types require prospective investigation.


2018 ◽  
Vol 31 (2) ◽  
pp. 197-202 ◽  
Author(s):  
Ji Young Bang ◽  
Sachin Kirtane ◽  
Konrad Krall ◽  
Udayakumar Navaneethan ◽  
Muhammad Hasan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document