scholarly journals Totally endoscopic aortic valve replacement via an anterolateral approach using a standard prosthesis

2019 ◽  
Vol 30 (3) ◽  
pp. 424-430 ◽  
Author(s):  
Masayoshi Tokoro ◽  
Sadanari Sawaki ◽  
Takahiro Ozeki ◽  
Mamoru Orii ◽  
Akihiko Usui ◽  
...  

Abstract OBJECTIVES Totally endoscopic aortic valve replacement (AVR) is still a challenging operation, and only a few series reports exist in the literature. The purposes of this study were to establish a method for endoscopic AVR and evaluate its initial results. METHODS A total of 47 patients (median age 76 years, 17 men) underwent endoscopic AVR. The main wound was created in the right anterolateral 4th intercostal space through a 4-cm skin incision. No rib spreader was used. A 3-dimensional endoscope was inserted at the midaxillary line. A 5.5-mm trocar was inserted in the 3rd intercostal space, thus creating a 3-port setting similar to that used for endoscopic mitral valve surgery. A standard prosthesis was used, and the sutures were tied using a knot pusher. Results were compared with those of 157 patients who underwent right transaxillary AVR with direct vision plus endoscopic assist. RESULTS Patient backgrounds did not differ significantly between the 2 groups. No deaths occurred in the entire series. There was no conversion to thoracotomy or sternotomy in the endoscopic AVR group. The complication rate did not differ significantly between the 2 groups. The total operating time was significantly shorter in endoscopic AVR (188–206 min); the cardiopulmonary bypass time (130–128 min) and the cross-clamp time (90–95 min) did not differ significantly (median, endoscopic AVR, right transaxillary AVR). Two patients underwent endoscopic double-valve (aortic and mitral) surgery under the same conditions. CONCLUSIONS Endoscopic AVR was possible through 3 ports created in the right anterolateral chest, similar to the procedure for endoscopic mitral valve surgery. By adopting a common approach for both the aortic and the mitral valve operations, endoscopic double-valve surgery can be performed seamlessly.

2002 ◽  
Vol 74 (4) ◽  
pp. 1115-1119 ◽  
Author(s):  
Jong-Won Ha ◽  
Seung-Hyuck Choi ◽  
Byung-Chul Chang ◽  
Chung Mo Nam ◽  
Yangsoo Jang ◽  
...  

2017 ◽  
Vol 3 (1) ◽  
pp. 30
Author(s):  
Anupama Barua ◽  
Rose J. Mills ◽  
Pankaj Kaul ◽  
David J. O’Regan

Atrioventricular groove (AVG) disruption is a fatal complication after mitral valve surgery with high mortality. Here we present a case of aortic valve replacement complicated with AVG disruption.


Sign in / Sign up

Export Citation Format

Share Document