Verification of Control Method for a Loop Distribution System using Loop Power Flow Controller

Author(s):  
Naotaka Okada
Author(s):  
Shirui Feng ◽  
Xi Wu ◽  
Zhenquan Wang ◽  
Tao Niu ◽  
Qiong Chen

AbstractWith the continuous expansion of power systems and the application of power electronic equipment, forced oscillation has become one of the key problems in terms of system safety and stability. In this paper, an interline power flow controller (IPFC) is used as a power suppression carrier and its mechanism is analyzed using the linearized state-space method to improve the system damping ratio. It is shown that although the IPFC can suppress forced oscillation with well-designed parameters, its capability of improving the system damping ratio is limited. Thus, combined with the repetitive control method, an additional repetitive controller (ARC) is proposed to further dampen the forced power oscillation. The ARC control scheme is characterized by outstanding tracking performance to a system steady reference value, and the main IPFC controller with the ARC can provide higher damping, and further reduce the amplitude of oscillations to zero compared with a supplementary damping controller (SDC). Simulation results show that the IPFC with an ARC can not only greatly reduce the oscillation amplitude, but also actively output the compensation power according to the reference value of the ARC tracking system.


2014 ◽  
Vol 626 ◽  
pp. 184-189
Author(s):  
A.S. Monikandan ◽  
N. Kesavan Nair

The Interline Power Flow Controller (IPFC) is a voltage-source-converter (VSC)-based flexible ac transmission system (FACTS) controller for series compensation in a multiline transmission system of a substation. The capability of injecting series voltages with controllable magnitude and phase angle makes it a powerful tool for better utilization of existing transmission lines in a multiline transmission system. IPFC is used to regulate active and reactive power flow in a multiline system, usually. In this paper, a control method for IPFC is proposed to control magnitude and phase angle of one sending bus of a substation. All degrees of freedom of IPFC and decoupled synchronous frame concept are used in the proposed control structure. Simulation results in Matlab/Simulink are presented to show the capability of IPFC in compensating the bus voltage.


2014 ◽  
Vol 573 ◽  
pp. 352-355
Author(s):  
Bojaraj Soumya Latha ◽  
A. Amudha

A power system structure has the generation, transmission and the distribution systems. During the transfer of power from the generation system to the distribution system, transmission line losses are occurred. To reduce the losses and keep the system stable, many controllers are being used. The Flexible AC Transmission systems (FACTS) are the modern controllers finding application in the power systems. The Unified Power Flow Controller (UPFC) is considered to be the best among the FACTS devices. It is installed in the transmission line to maintain the voltage of the system within the prescribe limits. The location to fix the UPFC is found using Shuffled Leap Frog Algorithm (SLFA). The transformer ratio is varied from its nominal value. Testing is done using an IEEE 30 bus system and the results are discussed.


Sign in / Sign up

Export Citation Format

Share Document