The Elongation Behavior of the Anterior Cruciate Ligament Graft in Vivo

2001 ◽  
Vol 29 (2) ◽  
pp. 161-166 ◽  
Author(s):  
Bruce D. Beynnon ◽  
Benjamin S. Uh ◽  
Robert J. Johnson ◽  
Braden C. Fleming ◽  
Per A. Renström ◽  
...  
2000 ◽  
Vol 122 (6) ◽  
pp. 600-603 ◽  
Author(s):  
Isaac Zacharias ◽  
M. L. Hull ◽  
Stephen M. Howell

To determine which exercises do not overload the graft-fixation complex during intensive rehabilitation from reconstructive surgery of the anterior cruciate ligament (ACL), it would be useful to measure ACL graft loads during rehabilitative activities in vivo in humans. A previous paper by Ventura et al. (1998) reported on the design of an implantable transducer integrated into a femoral fixation device and demonstrated that the transducer could be calibrated to measure graft loads to better than 10 percent full-scale error in cadaveric knees. By measuring both the static and fatigue strengths of the transducer, the purpose of the present study was to determine whether the transducer could be safely implanted in humans without risk of structural failure. Eight devices were loaded to failure statically. Additionally, seven devices were tested using the up-and-down method to estimate the median fatigue strength at a life of 225,000 cycles. The average ultimate strength was 1856±74 N and the median fatigue strength was 441 N at a life of 225,000 cycles. The maximum graft load during normal daily activities is estimated to be 500 N and the 225,000 cycle life corresponds to that of the average healthy individual during a 12-week period. Considering that patients who have had an ACL reconstruction are less ambulatory than normal immediately following surgery and that biologic incorporation of the graft should be well developed by 12 weeks thus decreasing the load transmitted to the fixation device, the FDT can be safely implanted in humans without undue risk of structural failure. [S0148-0731(00)00606-3]


2010 ◽  
Vol 132 (8) ◽  
Author(s):  
Conrad K. Smith ◽  
M. L. Hull ◽  
S. M. Howell

A millimeter-for-millimeter relation between an increase in length of an anterior cruciate ligament graft construct and an increase in anterior laxity has been demonstrated in multiple in vitro studies. Based on this relation, a 3 mm increase in length of the graft construct following surgery could manifest as a 3 mm increase in anterior laxity in vivo, which is considered clinically unstable. Hence, the two primary objectives were to determine whether the millimeter-for-millimeter relation exists in vivo for slippage-resistant fixation of a soft-tissue graft and, if it does not exist, then to what extent the increase in stiffness caused by biologic healing of the graft to the bone tunnel offsets the potential increase in anterior laxity resulting from lengthening at the sites of fixation. Sixteen subjects were treated with a fresh-frozen, nonirradiated, nonchemically processed tibialis allograft. Tantalum markers were injected into the graft, fixation devices, and bones. On the day of surgery and at 1, 2, 3, and 4 months, Roentgen stereophotogrammetric analysis was used to compute anterior laxity at 150 N of anterior force and the total slippage from both sites of fixation. A simple linear regression was performed to determine whether the millimeter-for-millimeter relation existed and a springs-in-series model of the graft construct was used to determine the extent to which the increase in stiffness caused by biological healing of the graft to the bone tunnel offset the increase in anterior laxity resulting from lengthening at the sites of fixation. There was no correlation between lengthening at the sites of fixation and the increase in anterior laxity at 1 month (R2=0.0, slope=0.2). Also, the increase in stiffness of the graft construct caused by biologic healing of the graft to the bone tunnel offset 0.7 mm of the 1.5 mm potential increase in anterior laxity resulting from lengthening at the sites of fixation. This relatively large offset of nearly 50% occurred because lengthening at the sites of fixation was small.


2018 ◽  
Vol 32 (05) ◽  
pp. 441-447
Author(s):  
Richard Ma ◽  
Mark Stasiak ◽  
Xiang-Hua Deng ◽  
Scott Rodeo

AbstractThe purpose of this study is to establish a small animal anterior cruciate ligament (ACL) reconstruction research model where ACL graft force can be varied to create different graft force patterns with controlled knee motion. Cadaveric (n = 10) and in vivo (n = 10) rat knees underwent ACL resection followed by reconstruction using a soft tissue autograft. Five cadaveric and five in vivo knees received a nonisometric, high-force femoral graft tunnel position. Five cadaveric and five in vivo knees received a more isometric, low-force graft tunnel position. ACL graft force (N) was then recorded as the knee was ranged from extension to 90 degrees using a custom knee flexion device. Our results demonstrate that distinct ACL graft force patterns were generated for the high-force and low-force femoral graft tunnels. For high-force ACL grafts, ACL graft forces increased as the knee was flexed both in cadaveric and in vivo knees. At 90 degrees of knee flexion, high-force ACL grafts had significantly greater mean graft force when compared with baseline (cadaver: 7.76 ± 0.54 N at 90 degrees vs. 4.94 ± 0.14 N at 0 degree, p = 0.004; in vivo: 7.29 ± 0.42 N at 90 degrees vs. 4.74 ± 0.13 N at 0 degree, p = 0.007). In contrast, the graft forces for low-force ACL grafts did not change with knee flexion (cadaver: 4.94 ± 0.11 N at 90 degrees vs. 4.72 ± 0.14 N at 0 degree, p = 0.41; in vivo: 4.78 ± 0.26 N at 90 degrees vs. 4.77 ± 0.06 N at 0 degree, p = 1). Compared with nonisometric ACL grafts, the graft force for grafts placed in an isometric position had significantly lower ACL graft forces at 15, 30, 45, 60, 70, and 90 degrees in both cadaveric and in vivo knees. In conclusion, we have developed a novel ACL reconstruction model that can reproducibly produce two ACL graft force patterns. This model would permit further research on how ACL graft forces may affect subsequent graft healing, maturation, and function.


1997 ◽  
Vol 15 (5) ◽  
pp. 645-651 ◽  
Author(s):  
William R. Lundberg ◽  
Jack L. Lewis ◽  
Joel J. Smith ◽  
Conrad Lindquist ◽  
Toni Meglitsch ◽  
...  

2018 ◽  
Vol 24 (3-4) ◽  
pp. 322-334 ◽  
Author(s):  
Corina Adriana Ghebes ◽  
Nathalie Groen ◽  
Yau Chuk Cheuk ◽  
Sai Chuen Fu ◽  
Hugo Machado Fernandes ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document