Arterial Stenosis Affecting Arteriovenous Fistulae and Grafts in Hemodialysis Patients: Approach to Diagnosis and Management

2021 ◽  
pp. 165-175
Author(s):  
Diego A. Covarrubias ◽  
Chieh Suai Tan ◽  
Shaker S. Qaqish ◽  
Karthik Ramani ◽  
Steven Wu
2021 ◽  
Vol 36 (Supplement_1) ◽  
Author(s):  
Marieta Theodorakopoulou ◽  
Foteini Iatridi ◽  
Charalampos Loutradis ◽  
Maria Eleni Alexandrou ◽  
Antonios Karpetas ◽  
...  

Abstract Background and Aims Hypertension is highly prevalent in hemodialysis patients. Current recommendations suggest the use of ambulatory-BP-monitoring (ABPM) as the gold-standard for hypertension diagnosis and management in these subjects. This study assessed the accuracy of peridialytic, intradialytic and scheduled interdialytic recordings in diagnosing high 44-h interdialytic BP. Method A total of 242 hemodialysis patients that underwent valid 48-h ABPM were included in the analysis. We used ambulatory BP as reference standard and tested the accuracy of the following BP metrics: Pre- and post-dialysis, Intradialytic, Intradialytic plus pre/post-dialysis readings and Scheduled interdialytic BP (out-of-dialysis day: readings at 8:00 am, 8:00 pm or their average). Results 44-h SBP/DBP levels had significant differences with and pre- or post-dialysis BP, but no or minor differences with any of the other BP metrics. 44-h SBP and DBP correlated strongly with Intradialytic (r=0.713/0.753, p<0.001), Intradialytic plus pre/post-dialysis (r=0.725/0.758, p<0.001) and averaged Scheduled interdialytic BP (r=0.874/0.823, p<0.001). Bland-Altman plots showed absence of systemic bias for all index metrics, but large between-method difference and wider 95% limits of agreement for pre- and post-dialysis BP compared to Intradialytic, Intradialytic plus pre/post-dialysis and averaged Scheduled interdialytic BP. In ROC-analysis for diagnosing 44-h SBP≥130mmHg, the Area-Under-the-Curve of pre-dialysis (0.723) and post-dialysis SBP (0.746) were significantly lower than that of Intradialytic (0.850), Intradialytic plus pre/post-dialysis (0.850) and Scheduled interdialytic SBP (0.917) (z-test, p<0.001 for all pairwise comparisons). The corresponding sensitivity/specificity values were 76.6%/54.5%, 78.7%/59.4%, 73.0%/81.2%, 68.1%/88.1% and 82.3%/89.1%, respectively. Similar observations were made for DBP. Conclusion In contrast to pre- and post-dialysis BP, the average of intradialytic, intradialytic plus pre/post-dialysis or scheduled interdialytic BP recordings show reasonable agreement with ambulatory BP and may be used for hypertension diagnosis and management in hemodialysis.


Author(s):  
Robert J. Rothrock ◽  
Clayton Haldeman ◽  
Ashish Shah ◽  
Victor M. Lu ◽  
Efrat Saraf Lavi ◽  
...  

2006 ◽  
Vol 25 (2) ◽  
pp. 151-154 ◽  
Author(s):  
J. Janzen ◽  
V. Mickley

ASAIO Journal ◽  
2003 ◽  
Vol 49 (5) ◽  
pp. 554-555 ◽  
Author(s):  
Terrence F. Oder ◽  
Victoria Teodorescu ◽  
Jaime Uribarri

Sign in / Sign up

Export Citation Format

Share Document