scholarly journals Effective Delayed Neutron Fraction

Author(s):  
Masao Yamanaka

AbstractIn kinetic analyses on ADS, although adjoint flux distribution is defined under the existence of an external neutron source, an issue of the proper determination of the weighting function still remains in the definition to obtain the kinetics parameters in the fixed-source calculations. Here, an alternative methodology is proposed with the combined use of the k-ratio method and the reaction rates obtained by the fixed-source calculations, when the subcriticality level or the spectrum of the external neutron source is varied. In ADS experiments, the measurement of βeff is expected to provide complementary verification of the calculation and reliability of nuclear data. Then, the formulation of the Rossi-α method in the pulsed-neutron source has been already available for application to the subcriticality measurement in the pulsed-neutron source (PNS) experiments. Accordingly, the methodology is applied uniquely to deduce the βeff value with the pulsed-neutron source (spallation neutrons), with the combined use of the results of experiments and calculations. Using parameters α and ρ$, the values of βeff/Λ are deduced at near-critical configurations through experimental analyses. To estimate the numerical precision of Λ, the value of βeff/Λ is used as an index of Λ evaluation that is defined by a ratio of Λ values in the super-critical and subcritical states.

Author(s):  
Shibiao Pan

During the operating of nuclear reactor, the applicable condition of point reactor neutron kinetics is changed by control rods bulk insertion and reactor lattice deviating from the critical state, The measurement of reactivity, with the increase of subcriticality, shows that the results impact on the kinetic distortion effect, along with prompt neutron flux strongly deteriorated. According to the diffusion theory about prompt neutron and delayed neutron, the theoretical analysis and application of point reactor neutron kinetics have been carried out to quantify the kinetic distortion correction factors in subcritical systems, and these indicate that prompt neutron distributions are strongly affected by kinetic distortion. With the self-developed Pulsed Neutron Source measurement system, subcriticality measurement in different configuration of control rods in the zero power reactor of Nuclear Power Institute of China was carried out. In this paper the reactivity of the deep subcritical system are obtained by experiment of Pulsed Neutron Source method, meanwhile, the bias between experiment results of the areas-ratio method and the characteristic decay constant method are analyzed by comparing the condition of the experiment and the theory model, the main factors inducing the bias are found, which supplies helpful reference for other similar design and experiment.


2020 ◽  
Vol 15 (11) ◽  
pp. T11006-T11006
Author(s):  
A. Sumbaev ◽  
V. Kobets ◽  
V. Shvetsov ◽  
N. Dikansky ◽  
P. Logatchov

AIP Advances ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 075005
Author(s):  
Carlo Cazzaniga ◽  
Antonella Scherillo ◽  
Anna Fedrigo ◽  
Davide Raspino ◽  
Francesco Grazzi ◽  
...  

1979 ◽  
Vol 26 (3) ◽  
pp. 3006-3008 ◽  
Author(s):  
Antanas V. Rauchas ◽  
Franklin R. Brumwell ◽  
Gerald J. Volk

2013 ◽  
Vol 8 (10) ◽  
pp. P10001-P10001 ◽  
Author(s):  
G Burca ◽  
W Kockelmann ◽  
J A James ◽  
M E Fitzpatrick

Sign in / Sign up

Export Citation Format

Share Document