Optimisation of the round window opening in cochlear implant surgery in wet and dry conditions: impact on intracochlear pressure changes

2016 ◽  
Vol 273 (11) ◽  
pp. 3609-3613 ◽  
Author(s):  
Philipp Mittmann ◽  
A. Ernst ◽  
M. Mittmann ◽  
I. Todt
2016 ◽  
Vol 6 (1) ◽  
pp. 1-8 ◽  
Author(s):  
Ingo Todt ◽  
Arneborg Ernst ◽  
Philipp Mittmann

Intracochlear pressure changes during the cochlear implant insertion are assumed to be an important contributor to hearing preservation. The aim was to observe intracochlear pressure changes by different round window opening sizes and different hydrophilic electrode conditions. The experiments were performed in a cochlear model with a micropressure sensor in the helicotrema area. Different artificial round window membrane and different moisturized electrode conditions were compared. A punctured round window causes a significantly higher and an indirect moisturized electrode condition a significantly lower intracochlear pressure change. The degree of round window opening and the hydrophilic character of an electrode during insertion affect the intracochlear pressure significantly in a model.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
P. Mittmann ◽  
A. Ernst ◽  
I. Todt

To preserve residual hearing in cochlea implantation, the electrode design has been refined and an atraumatic insertion of the cochlea electrode has become one aspect of cochlea implant research. The opening of the round window can be assumed to be a contributing factor in an atraumatic concept. The aim of our study was to observe intracochlear pressure changes due to different opening conditions of an artificial round window membrane. The experiments were performed in an artificial cochlea model. A round window was simulated with a polythene foil and a pressure sensor was placed in the helicotrema area to monitor intraluminal pressure changes. Openings of the artificial round window membrane were performed using different ways. Opening the artificial round window mechanically showed a biphasic behaviour of pressure change. Laser openings showed a unidirectional pressure change. The lowest pressure changes were observed when opening the artificial round window membrane using a diode laser. The highest pressure changes were seen when using a needle. The openings with the CO2laser showed a negative intracochlear pressure and a loss of fluid. In our model experiments, we could prove that the opening of the artificial round window membrane causes various intracochlear pressure changes.


2020 ◽  
Vol 8 (2) ◽  
pp. 432-436 ◽  
Author(s):  
Mozafar Sarafraz ◽  
Mahsa Heidari ◽  
Arash Bayat ◽  
Mohammad Ghasem Hanafi ◽  
Ali Fahimi ◽  
...  

2019 ◽  
Vol 128 (6_suppl) ◽  
pp. 38S-44S ◽  
Author(s):  
Seong-Cheon Bae ◽  
You-Ree Shin ◽  
Young-Myoung Chun

Objectives: The benefit of round window (RW) approach for cochlear implant (CI) has been well studied. Because the RW represents a natural door to scala tympani, it facilitates precise electrode insertion. Atraumatic electrode insertion can also be performed without drilling the cochlear lateral wall. However, the RW approach has several limitations. The purpose of this study is to describe successful CI surgeries utilizing the RW approach except for severe cases of temporal bone anomaly. The authors’ successful surgical solution for cases involving difficult RW access is also described. Materials and Methods: We retrospectively analyzed 377 consecutive surgeries of cochlear implantation performed between June 2010 and December 2018 by a single experienced surgeon. Standard and alternative procedures were used according to anatomical variations. Standard procedures included modified techniques of mastoidectomy in the RW approach, opening of facial recess, exposure of RW membrane, and electrode insertion. Difficult cases involving severe rotated cochlea or hypoplastic mastoid were successfully treated with RW insertion using alternative procedures such as external auditory canal (EAC) wall mobilization and endomeatal approach. Results: We performed CI surgery through a reproducible RW technique in two cases involving endomeatal approach and three cases of EAC mobilization. Other cases were treated using the standard procedure. Conclusion: Cochlear implant surgery through RW is reliable, safe, and effective. The RW technique is reproducible via several surgical procedures in most CI cases. Identification and safe exposure of RW membrane is a prerequisite for successful electrode insertion in cochlear implant surgery.


2014 ◽  
Vol 273 (1) ◽  
pp. 43-50 ◽  
Author(s):  
Karl Fredrik Nordfalk ◽  
Kjell Rasmussen ◽  
Marie Bunne ◽  
Greg Eigner Jablonski