scholarly journals The impact of two different inspiratory to expiratory ratios (1:1 and 1:2) on respiratory mechanics and oxygenation during volume-controlled ventilation in robot-assisted laparoscopic radical prostatectomy: a randomized controlled trial

2015 ◽  
Vol 62 (9) ◽  
pp. 979-987 ◽  
Author(s):  
Min-Soo Kim ◽  
Na Young Kim ◽  
Ki-Young Lee ◽  
Young Deuk Choi ◽  
Jung Hwa Hong ◽  
...  
2020 ◽  
Vol 24 (1) ◽  
pp. 36-41
Author(s):  
Asma Khan ◽  
Mukul Chandra Kapoor ◽  
Shaloo Garg ◽  
Archana Puri ◽  
Ashish Sinha

Background: A fear of potential gas leak limits the wide spread use of minimal flow anesthesia with supraglottic airway devices. Second generation supraglottic airway devices have been claimed to be come with good airway seal. I-gel is one of these and it has been extensively evaluated for spontaneous as well as assisted ventilation. We conducted this study to evaluate its use with low flow anesthesia and volume controlled ventilation. Methodology: In a prospective randomized controlled trial, 50 patients undergoing laparoscopic surgeries for less than 2 h duration were administered general anesthesia, with controlled ventilation, using either endotracheal tube or an I-gel for airway control. The total fresh gas flow was gradually reduced until it was 400 mL/min. Patients were monitored for evidence of loss of respiratory gas volume in the breathing circuit and other parameters for ventilation failure. Results: Ventilation could be maintained at a fresh gas flow of 400 mL/min, without clinical or volumetric evidence of gas leak in all patients in the two groups. Two patients in the I-gel group had intraoperative gas leak leading to ventilator failure alarm but the same was corrected by repositioning of the head. The vital signs, peak airway pressure, end-tidal carbon dioxide, set tidal volume and expired tidal volumes were statistically similar in the two groups. Conclusion: I-gel supraglottic airway can be safely and efficiently used for laparoscopic surgery using minimal flow anesthesia and volume controlled ventilation. Citation: Khan A, Kapoor MC, Garg S, Puri A, Sinha A. I-gel supraglottic airway use is efficient and safe during minimal flow anesthesia with volume controlled ventilation - a randomized controlled trial. Anaesth pain intensive care 2020;24(1):__ Abbreviations: Supraglottic airway device – SAD; Volume controlled ventilation – VCV; Pressure controlled ventilation – PCV; Endotracheal tube – ETT; Laryngeal Mask Airway - LMA   DOI: https://doi.org/10.35975/apic.v24i1. Received – 11 June 2019; Reviewed – 20, 23 October 2019; Revised – 31 January 2020; Second Review – 2, 7 January 2020; Accepted – 02 February 2020;


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Toshiyuki Nakanishi ◽  
Seishi Sakamoto ◽  
Manabu Yoshimura ◽  
Takashi Toriumi

Abstract Background During laparoscopic gynecological surgery, increased peak airway pressure (PAWP) can cause airway leak upon ventilation with the LMA® ProSeal™. We hypothesized that compared with the use of volume-controlled ventilation (VCV), the use of the AutoFlow® mode would decrease PAWP and airway leak during laparoscopic gynecological surgery with LMA ProSeal. Methods This single-center, randomized, controlled trial allocated 80 adult women undergoing elective laparoscopic gynecological surgery to one of two groups, namely, the AutoFlow group or the VCV group. Ventilation settings for both groups were 8 ml/kg of tidal volume and 5 cmH2O of positive end-expiratory pressure, and respiratory rate was adjusted to maintain end-tidal carbon dioxide at 35–40 mmHg. Airway leak, PAWP, and other ventilatory parameters and vital signs were recorded at four timepoints (1, 1 min after insertion of the gastric tube; 2, 2 min after intravenous administration of rocuronium 0.6–0.8 mg/kg; 3, 1 min after initiation of pneumoperitoneum; and 4, 1 min after changing to the Trendelenburg position). The primary outcome was PAWP during pneumoperitoneum and in the Trendelenburg position, whereas the secondary outcomes included PAWP at other timepoints and airway leak development. We used the Mann–Whitney U test for PAWP and Fisher’s exact test for comparing airway leak among the groups. Results Data from 40 patients in the AutoFlow group and 39 in the VCV group were used for analysis. PAWP at pneumoperitoneum pressure and in the Trendelenburg position was significantly lower in the AutoFlow group than in the VCV group [median (interquartile range), 16 (15–18) cmH2O vs. 18 (17–19) cmH2O; P < 0.001]. Similarly, patients in the AutoFlow group showed lower PAWP at the other three timepoints measured. Airway leak occurred in four patients in the AutoFlow group and in two patients in the VCV group; however, this incidence was not significantly different (P = 0.68). Conclusions Even though AutoFlow ventilation decreased PAWP, it did not reduce the incidence of airway leak compared with VCV during laparoscopic gynecological surgery with the LMA ProSeal. Trial registration UMIN Clinical Trials Registry, identifier UMIN000023173.


Sign in / Sign up

Export Citation Format

Share Document