Elective mapping and surgical division of the bundle of kent in a patient with Ebstein's anomaly who required tricuspid valve replacement

1978 ◽  
Vol 41 (3) ◽  
pp. 602-605 ◽  
Author(s):  
John D. Kugler ◽  
Paul C. Gillette ◽  
Desmond F. Duff ◽  
Denton A. Cooley ◽  
Dan G. McNamara
CHEST Journal ◽  
1988 ◽  
Vol 94 (5) ◽  
pp. 1096 ◽  
Author(s):  
Francesco Di Letto ◽  
Robert J. Flemma ◽  
Donald C. Mullen ◽  
Leonard H. Kleinman ◽  
Paul H. Werner

2020 ◽  
Vol 59 (1) ◽  
pp. 170-179
Author(s):  
Peng Liu ◽  
Dong-Sheng Xia ◽  
Wei-Hua Qiao ◽  
Dan Hu ◽  
Adnan Ahmed ◽  
...  

Abstract OBJECTIVES The debate concerning the optimal choice of tricuspid position continues. We compared the long-term results of mechanical and biological prostheses in patients who underwent isolated or combined tricuspid valve replacement, at 2 major cardiac surgical centres in central China. METHODS From January 1999 to December 2018, 338 patients underwent tricuspid valve replacement. Patients were divided into an isolated group or a combined group according to whether their surgery was combined with a left heart valve surgery. Mechanical tricuspid valve replacement was performed in 142 patients (isolated group: 41 vs combined group: 101), and 196 patients underwent bioprosthetic tricuspid valve replacement (isolated group: 145 vs combined group: 51). Operative results, long-term survival and tricuspid valve-related events were compared. RESULTS Early mortality in the combined group was higher (n = 6, 4%) than that in the isolated group (n = 3, 2%), but no significant difference was observed between the mechanical and biological subgroups. In the isolated group, there was a higher event-free rate in the biological subgroup than in the mechanical subgroup (P = 0.042) and a similar result was also observed for patients without Ebstein’s anomaly (P = 0.039). In the combined group, no significant difference was observed (P = 0.98). Survival rates were similar between the mechanical and biological subgroups in both the isolated (P = 0.54) and combined (P = 0.81) groups. Mechanical valves in isolated tricuspid valve replacement were more prone to valve thrombosis and bleeding. CONCLUSIONS Every decision regarding tricuspid valve prostheses should be individualized, but biological prostheses may be an optimal choice for patients, especially for patients without Ebstein’s anomaly, in isolated tricuspid valve replacement.


1998 ◽  
Vol 66 (5) ◽  
pp. 1539-1544 ◽  
Author(s):  
H.Tarik Kiziltan ◽  
David A Theodoro ◽  
Carole A Warnes ◽  
Patrick W O’Leary ◽  
Betty J Anderson ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document