Letter to the Editor: “Fluid reservoir thickness and corneal oedema during closed eye scleral lens wear,” by Damien Fisher, Michael J. Collins, and Stephen J. Vincent

Author(s):  
Young Hyun Kim ◽  
Meng C. Lin ◽  
Clayton J. Radke
2021 ◽  
Vol 5 (1) ◽  
pp. e1-e8
Author(s):  
Langis Michaud ◽  
Gabriella Courey

PurposeThis study aims to determine if lens or tear fluid reservoir thicknesses (LT/FRT) may influence the presence of residual astigmatism and participant’s visual acuity. MethodsThe study was a randomized, non-dispensing, prospective study. Empirically and randomly chosen participants were fitted with 4 combinations (350 and 250 um LT fitted with 250 and 350 um FRT) of 16 mm diameter scleral lenses, designed using a corneo-scleral profiler software (sMap 3D, Visionary Optics, US). Lenses haptics were kept spherical for all lenses. They were evaluated under a slit lamp, anterior segement OCT (objective fluid reservoir and lens thicknesses), topography over lenses and aberrometry, after 30 minutes of lens wear. Spherico-cylindrical refraction and logMar acuity were also assessed. ResultsStudy population was composed of 24 participants aged 24.2 + 4.7 years old. Baseline refractive error was -2.3 + 1.6 D with -0.48 + 0.26 D of astigmatism. In vivo (OCT) lens A was 344.1 ± 15.4 um thick, fitted with a vault of 213.6 ± 42.4 um; Lens B was 346.2 ± 12.5/327.2 ± 44.8; Lens C was 260.3 ± 17.7/214.0 ± 40.6 um and Lens D was 262.2 ±13.2/330.8 ± 52.0 respectively. All lenses were found similarly decentered inferiorly by 0.10 to 0.15 um. BCVA was −0.32 + 0.08 (A), −0.21 + 0.10 (B), −0.28 + 0.08 (C), and −0.14 + 0.10 (D), compared to −0.25 + 0.08 (A), −0.11 + 0.10 (B), −0.23 + 0.06 (C), and −0.05 + 0.12 (D) when sphere only was compensated. Residual refractive astigmatism (RA = -0.50 to -0.75D) is found significantly higher based on the FRT (F=9.560; p=0.037) and not LT(F=0.429; p=0.522). There is no correlation be-tween RA and over-k readings (Lens A r=-0.078, p=0.773; Lens B r=−0.073, p=0.788; Lens C r=−0.345, p=0.171; Lend D r=0.019, p=0.944). Higher order aberrations, mostly vertical coma, were found clinically significant but not statistically different between lenses (A= 0.350 + 0.032; B=0.382 + 0.053, C=0.329 + 0.044 and D=0.385+ 0.062; p=0.776) ConclusionThis study proves that low level of RA may be found when scleral lenses are fitted on normal corneas. Its occurrence is related to the presence of high-order aberrations and less likely to lens flexure.


2021 ◽  
Vol 5 (1) ◽  
pp. e32-e43
Author(s):  
Obinwanne Junior Chukwuemeka ◽  
Damian C. Echendu ◽  
Isaura Ilorena D'Alva Brito dos Santos ◽  
Sharon Onwuka ◽  
Osazee Agbonlahor

Purpose: To determine if regional variation in post lens fluid reservoir thickness (PLFT) during scleral lens wear leads to regional variation in oxygen transmissibility and corneal edema during 4 hours of non-fenestrated scleral lens wear.Methods: About 20 healthy subjects (mean age, 28.8 ± 4.2 years) were fitted with nonfenestrated rotationally symmetric scleral lenses. Anterior segment optical coherence tomography was used to measure cornea thickness before and after lens wear, PLFT 10 minutes and 4 hours after lens application, and scleral lens thickness (with the scleral lens in situ) 4 hours after scleral lens application. These measurements were limited to the central 6 mm and divided into three zones (central, mid-peripheral, and peripheral zones). In the mid-peripheral and peripheral zones, eight principal meridians were measured, generating 17 measurement points in total. Scleral lens thickness and PLFT measurements were corrected for optical distortions by a series of equations. Oxygen transmissibility was calculated by dividing the scleral lens oxygen permeability by the optically-corrected scleral lens thickness, taking into account the oxygen permeability of saline and fluid reservoir thickness.Results: A significant regional variation in PLFT (F = 12.860, P = 0. 012) was observed after 10 minutes of the lens application, PLFT was thickest and thinnest in the inferotemporal and the superonasal region of the peripheral zones( 322.6 ± 161.8 µm and 153.8 ± 96.4 µm, respectively); however, this variation was not statistically significant at 4 hours of scleral lens wear (F = 4.692; P = 0.073). Despite significant regional variation in oxygen transmissibility (F = 48.472; P = 0.001) and relatively low oxygen transmissibility through the scleral lens, induced corneal edema did not vary significantly in different regions (F = 3.346; P = 0.126). In the central corneal region, the induced corneal edema correlated moderately with PLFT (r = 0.468; P = 0.037) and oxygen transmissibility (r = -0.528; P = 0.017). This relationship was insignificant in the peripheral cornea.Conclusion: The inferotemporal peripheral region had the thickest PLFT and least oxygen transmissibility, and the superonasal region had the vice versa. Despite significant variation in PLFT and oxygen transmissibility initially, in healthy corneas, this variation does not seem to induce statistically significant regional variation in corneal edema. Increased central PLFT and decreased oxygen transmissibility moderately correlate with central corneal edema.


2020 ◽  
Vol 97 (9) ◽  
pp. 683-689 ◽  
Author(s):  
Damien Fisher ◽  
Michael J. Collins ◽  
Stephen J. Vincent

2020 ◽  
Vol 43 (6) ◽  
pp. 577-584 ◽  
Author(s):  
Maria K Walker ◽  
Carolina Lema ◽  
Rachel Redfern
Keyword(s):  

2019 ◽  
Vol 42 (1) ◽  
pp. 49-54 ◽  
Author(s):  
Stephen J. Vincent ◽  
David Alonso-Caneiro ◽  
Michael J. Collins

Sign in / Sign up

Export Citation Format

Share Document