Effect on analgesia duration and pain intensity of adding dexamethasone to lidocaine in digital nerve block in patients with finger trauma

Author(s):  
E. Hazrati ◽  
M. Afsahi ◽  
M. Namazi ◽  
B. Kheradmand ◽  
M. Rafiei
2016 ◽  
Vol 21 (03) ◽  
pp. 369-373
Author(s):  
Solveig Ballo ◽  
Tonje Hjelseng ◽  
Lena Flatlandsmo Tangen ◽  
Janne Svindal Lundbom ◽  
Trine Skarsvåg ◽  
...  

Background: Digital nerve block is associated with pain. In a search for methods to reduce the discomfort, we investigated how the volume of anaesthetic fluid influences pain during subcutaneous digital nerve block, and how it affects the success of the anaesthesia. Methods: A randomized blinded prospective study was performed on 36 healthy volunteers. The single injection subcutaneous digital block technique was used to anaesthetize the participants´ 4th digit on both hands. The same amount of lidocaine was used, but in two different volumes; 1 ml 2% lidocaine and 2ml 1% lidocaine. After each injection the participant was asked to estimate pain intensity on a visual analogue scale (VAS). The distribution of anaesthesia was then measured by using a Semmes-Weinstein 4.56 monofilament. Finally, participants gave a verbal assessment of which injection was least painful. Results: In total, 72 blocks were performed. There were no statistically significant differences in pain intensity or preference between the two groups. Furthermore, the 1 ml injection gave poorer anaesthesia and had longer time to onset. Neither injection anaesthetized the dorsal aspect of the proximal phalanx. Conclusions: The two volumes cause the same degree of discomfort. Greater volume gives a greater area of distribution and more rapid onset of anaesthesia. It seems unreasonable to use a smaller volume of more concentrated anaesthetic when performing the subcutaneous technique.


1998 ◽  
Vol 23 (4) ◽  
pp. 490-493 ◽  
Author(s):  
N. S. SARHADI ◽  
J. SHAW-DUNN

Injection studies using methylene blue and latex were used in 60 digits from 40 cadavers to study how anaesthetic fluid injected into the flexor tendon sheath might spread around the proximal part of the finger. The injected solution escaped from the flexor tendon sheath around the vincular vessels which are present near the base and head of the proximal phalanx. Outside the digital canal, the dye flowed smoothly through the perivascular loose areolar tissue and spread alongside the main digital vessels and nerves and their palmar and dorsal branches.


2007 ◽  
Vol 24 (11) ◽  
pp. 789-790 ◽  
Author(s):  
P P Mohan ◽  
P T Cherian

Sign in / Sign up

Export Citation Format

Share Document