(i) Computer assisted surgical navigation (CASN) in total knee replacement. Soft tissue balancing and the role of dynamic assessment

2014 ◽  
Vol 28 (5) ◽  
pp. 279-285
Author(s):  
Ajeya Adhikari ◽  
Robin K. Strachan
Author(s):  
Daniel Hernandez-Vaquero ◽  
Alfonso Noriega-Fernandez ◽  
Sergio Roncero-Gonzalez ◽  
Gorka Luis Ruete-Gil ◽  
Jose Manuel Fernandez-Carreira

Abstract Introduction In complex and deformed knees, soft tissue release (STR) is required to obtain symmetry in the femorotibial gap. The objective of this study was to attempt to predict the need for soft tissue release using surgical navigation in total knee replacement (TKR). Methods Prospective and non-randomized study. One hundred thirty knees. At the start of navigation, an attempt was made to correct the femorotibial mechanical axis by applying force to the medial or lateral side of the knee (varus-valgus stress angle test). A gap balanced technique with computer-assisted surgery (CAS) was performed in all cases. The ligaments were tensioned, and using CAS visualization and control, progressive STR was performed in the medial or lateral side until a symmetry of the femorotibial gap was achieved. Results Eighty-two patients had a varus axis ≥ 3° and 38 had a valgus axis (P < 0.001). STR was performed under navigation control in 38.5% of cases, lateral release (LR) in 12 cases, and medial release (MR) in 38 cases. After performing the varus-valgus stress angle test (VVSAT), the axis of 0° could be restored at some point during the manoeuvre in 28 cases. STR was required in 44.6% of varus cases and 27% of valgus cases (P = 0.05). A significant relationship was found between the previous deformity and the need for MR (P < 0.001) or LR (P = 0.001). STR was more common in male patients (P = 0.002) and as obesity increased. Conclusion This study shows that pre-operative factors favouring the need to perform STR in a TKR implant can be defined.


The Knee ◽  
1995 ◽  
Vol 2 (1) ◽  
pp. 27-32
Author(s):  
R Johnson ◽  
K Barry ◽  
SAC Sampath ◽  
U Kanitkar

10.29007/t7tz ◽  
2019 ◽  
Author(s):  
Chumroonkiet Leelasestaporn ◽  
Tomorn Tarnpichprasert

INTRODUCTIONThe outcome of knee replacement depended on alignment, balancing of soft tissue, symmetrical andrectangular gaps adjustment, and accurate implant placement. Many techniques have been used toimprove these factors including navigator assisted knee replacement, which has precise bone cutand accurate soft tissue balancing. However, cementation may change gaps and alignment that canaffect outcome of knee replacement.OBJECTIVETo compare gaps and alignment after cementation in computer assisted total knee replacementMATERIAL AND METHODSProspective collecting data all cases performed computer assisted total knee replacement withcruciate retaining - mobile bearing implant design. Gaps and mechanical axis was collected andcompered between complete trial prosthesis and final cementation.RESULTLateral extension gap and flexion contracture significantly increase after cementation whencompared with trial implantation [0.6 mm (P = 0.021), 2.7o (P = 0.00)]. The mechanical axis was notdeviated after cementation (P = 1.00).CONCLUSIONCementation is able to influence gap and alignment. It may be useful to control and recheck gap andalignment with navigation system during cementation. Clinical correlation needs furtherinvestigation.


Author(s):  
Donald R. Johnson ◽  
Richard J. Friedman ◽  
John B. McGinty ◽  
J. Lorin Mason ◽  
Edward W.St. Mary

1994 ◽  
Vol 43 (4) ◽  
pp. 1399-1402
Author(s):  
Takashi Furugen ◽  
Nozomi Hatano ◽  
Masaaki Nohara ◽  
Tugukazu Touma ◽  
Hidemaro Higa