Ultra-Widefield Fundus Images are a Better Exploratory Technique than Indirect Ophthalmoscopy in Patients with a Type 1 Boston Keratoprosthesis

2020 ◽  
Vol 4 (6) ◽  
pp. 645-647
Author(s):  
Raul Velez-Montoya ◽  
Daniela Meizner-Grezemkovsky ◽  
Valeria Sanchez-Huerta ◽  
Emmanuel Cabrera ◽  
Juan Manuel Jimenez-Sierra ◽  
...  
Author(s):  
Dominique Geoffrion ◽  
Salima I. Hassanaly ◽  
Michael Marchand ◽  
Roy Daoud ◽  
Younes Agoumi ◽  
...  

2016 ◽  
Vol 37 (1) ◽  
pp. 263-266
Author(s):  
Riccardo Scotto ◽  
Aldo Vagge ◽  
Carlo E. Traverso

2012 ◽  
Vol 96 (6) ◽  
pp. 776-780 ◽  
Author(s):  
Marie-Claude Robert ◽  
Krystel Moussally ◽  
Mona Harissi-Dagher

2015 ◽  
Vol 235 (1) ◽  
pp. 61-61
Author(s):  
María Isabel Relimpio López ◽  
María Gessa Sorroche ◽  
Antonio Manuel Garrido Hermosilla ◽  
Teresa Laborda Guirao ◽  
Francisco Espejo Arjona ◽  
...  

Purpose: The aim is to describe the main characteristics of an anterior/posterior segment surgery and how to resolve intraoperative complications. Setting/Venue: The anterior and posterior segment surgical video was created at the Department of Ophthalmology, Virgin Macarena University Hospital, Seville, Spain. Methods: We present the case of a male with Stevens-Johnson syndrome and severe limbal deficiency who needed a Boston type 1 keratoprosthesis, reaching a visual acuity of 0.4 (0.05 before surgery). In the course of follow-up, he developed corneal melting with perforation, immune vitritis, and a large epimacular membrane. We decided to perform a 23-gauge vitrectomy associated with keratoprosthesis exchange. As a consequence of inappropriate anesthesia, the patient woke up during the surgery, provoking a retinal tear besides a choroidal detachment. These damages needed endolaser photocoagulation as well as silicone oil tamponade, forcing us to postpone the exchange. An intravitreal dexamethasone implant was also injected. Two months later, the silicone oil was removed, and the Boston keratoprosthesis was replaced by a new type 1 model with a titanium back plate, which likely improves biocompatibility and retention and may reduce complications such as retroprosthetic membranes and stromal corneal melts. Results: Good anatomical results were achieved, and visual acuity slightly improved to 0.2. Conclusions: Combined anterior and posterior segment surgery represents a great challenge that can improve not only visual acuity but also quality of life in patients with severe diseases such as Stevens-Johnson syndrome.


2018 ◽  
Vol 53 (3) ◽  
pp. 284-290 ◽  
Author(s):  
Jay C. Wang ◽  
Christopher J. Rudnisky ◽  
Michael W. Belin ◽  
Joseph B. Ciolino

Sign in / Sign up

Export Citation Format

Share Document