scholarly journals Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating

2012 ◽  
Vol 98 (2) ◽  
pp. 151-158 ◽  
Author(s):  
E. Sariali ◽  
R. Mauprivez ◽  
F. Khiami ◽  
H. Pascal-Mousselard ◽  
Y. Catonné
2021 ◽  
Vol 49 (11) ◽  
pp. 030006052110588
Author(s):  
Xuzhuang Ding ◽  
Bingshi Zhang ◽  
Wenao Li ◽  
Jia Huo ◽  
Sikai Liu ◽  
...  

Objective We performed a retrospective study to compare the accuracy of preoperative planning using three-dimensional AI-HIP software and traditional two-dimensional manual templating to predict the size and position of prostheses. The purpose of this study was to evaluate the accuracy of AI-HIP in preoperative planning for primary total hip arthroplasty. Methods In total, 316 hips treated from April 2019 to June 2020 were retrospectively reviewed. A typical preoperative planning process for patients was implemented to compare the accuracy of the two preoperative planning methods with respect to prosthetic size and position. Intraclass correlation coefficients (ICCs) were used to evaluate the homogeneity between the actual prosthetic size and position and the preoperative planning method. Results When AI-HIP software and manual templating were used for preoperative planning, the stem agreement was 87.7% and 58.9%, respectively, and the cup agreement was 94.0% and 65.2%, respectively. The results showed that when AI-HIP software was used, an extremely high level of consistency (ICC > 0.95) was achieved for the femoral stem size, cup size, and femoral osteotomy level (ICC = 0.972, 0.962, and 0.961, respectively). Conclusion AI-HIP software showed excellent reliability for predicting the component size and implant position in primary total hip arthroplasty.


2016 ◽  
Vol 45 (10) ◽  
pp. 1431-1435 ◽  
Author(s):  
Joseph Zerr ◽  
Yonatan Chatzinoff ◽  
Rajiv Chopra ◽  
Kenneth Estrera ◽  
Avneesh Chhabra

2018 ◽  
Vol 33 (2) ◽  
pp. 601-607 ◽  
Author(s):  
Yasushi Wako ◽  
Junichi Nakamura ◽  
Michiaki Miura ◽  
Yuya Kawarai ◽  
Masahiko Sugano ◽  
...  

2019 ◽  
Vol 2019 ◽  
pp. 1-7 ◽  
Author(s):  
Y. Knafo ◽  
F. Houfani ◽  
B. Zaharia ◽  
F. Egrise ◽  
I. Clerc-Urmès ◽  
...  

Two-dimensional (2D) planning on standard radiographs for total hip arthroplasty may not be sufficiently accurate to predict implant sizing or restore leg length and femoral offset, whereas 3D planning avoids magnification and projection errors. Furthermore, weightbearing measures are not available with computed tomography (CT) and leg length and offset are rarely checked postoperatively using any imaging modality. Navigation can usually achieve a surgical plan precisely, but the choice of that plan remains key, which is best guided by preoperative planning. The study objectives were therefore to (1) evaluate the accuracy of stem/cup size prediction using dedicated 3D planning software based on biplanar radiographic imaging under weightbearing and (2) compare the preplanned leg length and femoral offset with the postoperative result. This single-centre, single-surgeon prospective study consisted of a cohort of 33 patients operated on over 24 months. The routine clinical workflow consisted of preoperative biplanar weightbearing imaging, 3D surgical planning, navigated surgery to execute the plan, and postoperative biplanar imaging to verify the radiological outcomes in 3D weightbearing. 3D planning was performed with the dedicated hipEOS® planning software to determine stem and cup size and position, plus 3D anatomical and functional parameters, in particular variations in leg length and femoral offset. Component size planning accuracy was 94% (31/33) within one size for the femoral stem and 100% (33/33) within one size for the acetabular cup. There were no significant differences between planned versus implanted femoral stem size or planned versus measured changes in leg length or offset. Cup size did differ significantly, tending towards implanting one size larger when there was a difference. Biplanar radiographs plus hipEOS planning software showed good reliability for predicting implant size, leg length, and femoral offset and postoperatively provided a check on the navigated surgery. Compared to previous studies, the predictive results were better than 2D planning on conventional radiography and equal to 3D planning on CT images, with lower radiation dose, and in the weightbearing position.


Sign in / Sign up

Export Citation Format

Share Document