Gamma Rays And Thermal Neutron Attenuation Studies Of Special Composite Mixes For Using In Different Applications

Author(s):  
A.M. Abdelmonem
2021 ◽  
Author(s):  
Ahmed Mohamed Reda ◽  
A A El-Daly ◽  
E. A. Eid

Abstract In this work, the shielding performance of (97.3–x)Pb–xCd–2.7Ag (x=10, 18, and 30) ternary alloys against neutrons and gamma rays has been investigated. The microstructure, thermal and mechanical properties of the ternary alloys were examined. The total mass attenuation coefficients, μ⁄ρ, for prepared alloys were determined at 662, 1173, and 1332 keV photon energies using NaI (Tl) scintillation detector. The theoretical values of μ⁄ρ were calculated using WinXCom program depending on the mixture rule. The estimated values were compared with the measured values for all investigated alloys. Atomic cross-section, σa, electronic cross-section, σe, effective atomic number, Zeff, effective electron number, Neff, and GP fitting parameters (b, c, a, Xk, and d) were determined. The exposure buildup factor, EBF, have been also calculated. Fast neutron attenuation for the prepared samples have been investigated via the macroscopic effective removal cross-section (∑_R) calculation. Also, thermal neutron attenuation has been evaluated via neutron scattering calculator. The results show that the alloys containing 10 and 30% Cd compromise between superior tensile strength and Young modulus, while the pasty range, heat of fusion and ductility decreased with increasing Cd content. Moreover, the prepared ternary alloys have a high attenuation ability for gamma rays as the standard Pb. The increase of Cd ratio also significantly enhances the thermal neutron attenuation by amazing way along with the increase in the attenuation rate of fast neutrons.


1969 ◽  
Vol 126 (2) ◽  
pp. 392-400 ◽  
Author(s):  
R. Hardell ◽  
S.O. Idetjärn ◽  
H. Ahlgren

2020 ◽  
Vol 126 (3) ◽  
Author(s):  
G. Lakshminarayana ◽  
M. G. Dong ◽  
M. S. Al-Buriahi ◽  
Ashok Kumar ◽  
Dong-Eun Lee ◽  
...  

1999 ◽  
Vol 32 (5) ◽  
pp. 878-882 ◽  
Author(s):  
Y. Karasawa Haga ◽  
S. Kumazawa ◽  
N. Niimura

The energy dependence of gamma-ray sensitivity of a neutron imaging plate (NIP) has been measured. The gamma-ray sensitivity is equivalent to one half that of a thermal neutron at a gamma-ray energy less than 300 keV, and 1/40 at greater than 300 keV. The shielding of the NIP, by lead, from gamma rays in the experimental hall of the reactor JRR-3M of the Japan Atomic Energy Research Institute (JAERI) was measured. It was found that lead of thickness 40 mm is sufficient to reduce the gamma-ray background to 1/10 on a normalized scale. Covering the NIP with lead foil of thickness 1 mm results in a decrease of the gamma-ray background without reduction of the neutron signal.


1985 ◽  
Vol 32 (1) ◽  
pp. 18-69 ◽  
Author(s):  
S. Raman ◽  
R. F. Carlton ◽  
J. C. Wells ◽  
E. T. Jurney ◽  
J. E. Lynn

1982 ◽  
Vol 25 (5) ◽  
pp. 2232-2254 ◽  
Author(s):  
R. W. Hoff ◽  
W. F. Davidson ◽  
D. D. Warner ◽  
H. G. Börner ◽  
T. von Egidy

Sign in / Sign up

Export Citation Format

Share Document