scholarly journals An analysis of harmonic heating in smart buildings and distribution network implications with increasing non-linear (domestic) load and embedded generation

2018 ◽  
Vol 126 ◽  
pp. 524-536
Author(s):  
Chittesh Veni Chandran ◽  
Keith Sunderland ◽  
Malabika Basu
Author(s):  
Akram Qashou ◽  
Sufian Yousef ◽  
Abdallah A. Smadi ◽  
Amani A. AlOmari

AbstractThe purpose of this paper is to describe the design of a Hybrid Series Active Power Filter (HSeAPF) system to improve the quality of power on three-phase power distribution grids. The system controls are comprise of Pulse Width Modulation (PWM) based on the Synchronous Reference Frame (SRF) theory, and supported by Phase Locked Loop (PLL) for generating the switching pulses to control a Voltage Source Converter (VSC). The DC link voltage is controlled by Non-Linear Sliding Mode Control (SMC) for faster response and to ensure that it is maintained at a constant value. When this voltage is compared with Proportional Integral (PI), then the improvements made can be shown. The function of HSeAPF control is to eliminate voltage fluctuations, voltage swell/sag, and prevent voltage/current harmonics are produced by both non-linear loads and small inverters connected to the distribution network. A digital Phase Locked Loop that generates frequencies and an oscillating phase-locked output signal controls the voltage. The results from the simulation indicate that the HSeAPF can effectively suppress the dynamic and harmonic reactive power compensation system. Also, the distribution network has a low Total Harmonic Distortion (< 5%), demonstrating that the designed system is efficient, which is an essential requirement when it comes to the IEEE-519 and IEC 61,000–3-6 standards.


Author(s):  
Vito Calderaro ◽  
Vincenzo Galdi ◽  
Antonio Piccolo ◽  
Pierluigi Siano

The connection of distributed generation (DG) essentially changes the distribution network operation and creates a range of well-documented effects varying the voltage levels and short circuit currents. Among others, DG can alter protection system operations in distribution networks, leading to the failure of reclosing, the disconnection of the healthy feeder or the prevention of a protection operation. This paper proposes a procedure, based on Petri nets and supported by a centralized monitoring architecture, for monitoring failures of the protection systems in radial distribution networks. Some case studies applied to a real Italian distribution network proved the effectiveness of the proposed procedure that can therefore represent an effective solution to improve distribution systems reliability in the presence of DG.


2015 ◽  
Vol 8 (9) ◽  
pp. 1616-1624 ◽  
Author(s):  
Yong Li ◽  
Fang Liu ◽  
Tapan Kumar Saha ◽  
Olav Krause ◽  
Yijia Cao