Fraction-specific post-treatment quality assurance for active breath-hold radiation therapy

2019 ◽  
Vol 18 (03) ◽  
pp. 262-270
Author(s):  
Rajesh Thiyagarajan ◽  
Arunai Nambiraj ◽  
Durai Manigandan ◽  
Tamilseivan Singaravelu ◽  
Rajesh Selvaraj ◽  
...  

AbstractPurposeThe purpose of this study is to evaluate variation in the treatment hold pattern and quantify its dosimetric impact in breath-hold radiotherapy, using fraction-specific post-treatment quality assurance.Material and MethodsA patient with lung mets treated using intensity-modulated radiation therapy (IMRT) with active breath coordinator (ABC) was recruited for the study. Treatment beam hold conditions were recorded for all the 25 fractions. The linearity and reproducibility of the dosimetric system were measured. Variation in the dose output of unmodulated open beam with beam hold was studied. Patient-specific quality assurance (PSQA) was performed with and without beam hold, and the results were compared to quantify the dosimetric impact of beam hold.ResultsThere was a considerable amount of variation observed in the number of beam hold for the given field and the monitor unit at which the beam held. Linearity and reproducibility of the dosimetric system were found within the acceptable limits. The average difference over the 25 measurements was 0·044% (0·557 to −0·318%) with standard deviation of 0·248.ConclusionPatient comfort with the ABC system and responsiveness to the therapist communication help to maintain consistent breathing pattern, in turn consistent treatment delivery pattern. However, the magnitude of dosimetric error is much less than the acceptable limits recommended by IROC. The dosimetric error induced by the beam hold is over and above the dose difference observed in conventional PSQA.

2015 ◽  
Vol 49 (3) ◽  
pp. 307-313 ◽  
Author(s):  
Jaeman Son ◽  
Taesung Baek ◽  
Boram Lee ◽  
Dongho Shin ◽  
Sung Yong Park ◽  
...  

Abstract Background. This study was designed to compare the quality assurance (QA) results of four dosimetric tools used for intensity modulated radiation therapy (IMRT) and to suggest universal criteria for the passing rate in QA, irrespective of the dosimetric tool used. Materials and methods. Thirty fields of IMRT plans from five patients were selected, followed by irradiation onto radiochromic film, a diode array (Mapcheck), an ion chamber array (MatriXX) and an electronic portal imaging device (EPID) for patient-specific QA. The measured doses from the four dosimetric tools were compared with the dose calculated by the treatment planning system. The passing rates of the four dosimetric tools were calculated using the gamma index method, using as criteria a dose difference of 3% and a distance-to-agreement of 3 mm. Results. The QA results based on Mapcheck, MatriXX and EPID showed good agreement, with average passing rates of 99.61%, 99.04% and 99.29%, respectively. However, the average passing rate based on film measurement was significantly lower, 95.88%. The average uncertainty (1 standard deviation) of passing rates for 6 intensity modulated fields was around 0.31 for film measurement, larger than those of the other three dosimetric tools. Conclusions. QA results and consistencies depend on the choice of dosimetric tool. Universal passing rates should depend on the normalization or inter-comparisons of dosimetric tools if more than one dosimetric tool is used for patient specific QA.


2014 ◽  
Vol 2014 ◽  
pp. 1-5 ◽  
Author(s):  
Siji Cyriac ◽  
M. M. Musthafa ◽  
R. Ganapathi Raman ◽  
K. Abdul Haneefa ◽  
V. T. Hridya

Pretreatment quality assurance (QA) is a major concern in complex radiation therapy treatment plans like intensity modulated radiation therapy (IMRT). Present study considers the variations in gamma index for gantry dependent pretreatment verification and commonly practiced zero gantry angle verifications for ten prostate IMRT plans using two commercial medical linear accelerators (Varian 2300 CD, Varian Clinac iX). Two verification plans (the one with all fields at the actual treatment angles and one with all fields merged to 0 degree gantry angles) for all the patients were generated to obtain dose fluence mapping using amorphous silicon electronic portal imaging device (EPID). The gamma index was found depend on gantry angles but the difference between zero and the nonzero treatment angles is in the confidence level for clinical acceptance. The acceptance criteria of gamma method were always satisfied in both cases for two machines and are stable enough to execute the patient specific pretreatment quality assurance at 0 degree gantry angle for prostate IMRTs, where limited number of gantry angles are used.