scholarly journals Convenience of Hgb-O detected by optical method in XN-series hematology analyzers in evaluating hemoglobin concentration in samples with chylous turbidity

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yu Aruga ◽  
Chiaki Ikeda ◽  
Arisa Hanai ◽  
Sakiko Yoshimura ◽  
Momoko Kito ◽  
...  

AbstractThe chylous turbidity of blood samples is one of the causes of false-high hemoglobin (Hgb) concentration measurements by the colorimetric method, which has been widely applied in hematology analyzers. In such cases, additional manual procedures are required to correct Hgb concentrations. We therefore examined the effectiveness of an optical method for measuring Hgb concentrations in samples with chylous turbidity using Hgb-O in the reticulocyte channel equipped in XN-series analyzers (Sysmex, Kobe, Japan). Hgb-O showed excellent basic performance, including linear correlation and invariability with sodium lauryl sulfate (SLS)-Hgb detected by the colorimetric method. In the analysis of samples from healthy volunteers supplemented with fat emulsion, chylous turbidity did not affect Hgb-O but SLS-Hgb, which was falsely increased according to the dose of fat emulsion. Actually, SLS-Hgb was falsely elevated in 34 of 40 chylous turbidity 3+ samples. The remaining 6 samples were measured in hematology analyzers where Hgb-O was inconsistent with SLS-Hgb in the internal quality control records. For these samples, the correction factors calculated from the internal quality control records could contribute to providing the corrected Hgb-O value. These findings suggested that the optical method was effective and convenient for accurately evaluating Hgb concentrations in samples with extremely chylous turbidity.

2018 ◽  
Vol 33 (1) ◽  
pp. e22643 ◽  
Author(s):  
Huizhen Sun ◽  
Wei Wang ◽  
Haijian Zhao ◽  
Chuanbao Zhang ◽  
Falin He ◽  
...  

2021 ◽  
Vol 6 (2) ◽  
pp. 115-118
Author(s):  
Kafil Akhtar ◽  
Radhika Arora ◽  
Umrah Malik ◽  
Ankita Parashar ◽  
Murad Ahmad ◽  
...  

Quality control describes steps taken by blood and component bank to ensure that tests are performed correctly. Primary goal of quality control is transfusion of safe quality of blood. It is to ensure availability of efficient supply of blood and blood components. Internal quality control is the backbone of quality assurance program. To analyze the internal quality control of blood components in modern blood banking as an indicator of our blood bank performance. An observational cross sectional study conducted at the Blood and Component Bank, JN Medical College and Hospital from 2018 to 2020. Each blood component was arbitrarily chosen during the study on monthly basis. Selection criteria was 1.0% of total collection or minimum 4 bags per month. Packed red cells were evaluated for hemoglobin, hematocrit, RBC count; platelet concentrates for pH, yield and culture; fresh frozen plasma and cryoprecipitate were evaluated for unit volume, factor VIII and fibrinogen concentration. The mean HCT of packed red cells was 65.75+7.42%, volume was 238+26.25ml, Hb was 20.5+0.15g/dL and RBC count of 5.89x10+0.30x10. The mean platelet yield was 5.7x10, pH was ≥6.8+0.175 and volume was 82.5+13.75ml; cultures were negative and swirling was present in all the platelet units tested. Mean factor VIII and fibrinogen levels were found to be 95.25 +7.37and 307.5+41.37gm/l for FFP respectively. Mean volume, PT and APTT were 215+32.5ml, 14.15+0.325 sec and 29.50+1.5 sec respectively. The quality control of blood components ensures the timely availability of a blood component of high quality with maximum efficacy and minimal risk to potential recipients.


Sign in / Sign up

Export Citation Format

Share Document