scholarly journals Percutaneous Purse-String Suture: An Innovative Percutaneous Technique for Inframammary Fold Creation and Improved Breast Projection in Reconstructive Surgery

2017 ◽  
Vol 38 (12) ◽  
pp. 1298-1303 ◽  
Author(s):  
Moustapha Hamdi ◽  
Alexander Anzarut ◽  
Benoit Hendrickx ◽  
Socorro Ortiz ◽  
Assaf Zeltzer ◽  
...  
2018 ◽  
Vol 23 (1) ◽  
pp. 67-68 ◽  
Author(s):  
R. Wu ◽  
R. Benedict ◽  
A. Caycedo-Marulanda

2020 ◽  
pp. 112972982095474
Author(s):  
Sung-Joon Park ◽  
Hwan Hoon Chung ◽  
Seung Hwa Lee ◽  
Sung Beom Cho ◽  
Tae-Seok Seo ◽  
...  

Purpose: To evaluate the usefulness and feasibility of using a reversible clinch knot with a guidewire in place rather than eliminating the access route during an arteriovenous hemodialysis access (AV access) intervention using the facing sheath technique. Material and methods: From July 2016 to June 2019, we retrospectively studied 78 sessions performed as interventional treatment for arteriovenous (AV) hemodialysis (HD) access using the “facing-sheath technique.” In all sessions, all antegrade sheaths were removed while a 0.035-inch guidewire remained in place with purse-string suture and the clinch knot. Seventy-two sessions were performed in patients with thrombosed AV accesses (69 arteriovenous grafts [AVGs] and three arteriovenous fistulas [AVFs]), and six sessions were carried out to treat non-thrombosed AV accesses (four AVGs and two AVFs). We evaluated whether proper hemostasis and successful reinsertion of the sheath over the wire into the clinch knot was achieved. Clinical success was defined as achieving prompt restoration of blood flow for AV access, and the postintervention primary and secondary patency were also evaluated. Result: In all 87 clinch knots created in 78 total sessions, proper hemostasis was achieved. All clinch knots that required reversal for additional procedures were successfully reopened (55 clinch knots in 50 sessions). The postintervention primary patency rates at 1, 3, and 6 months, and at 1 year were 77.8%, 68.9%, 55.6%, and 33.3%, respectively. The postintervention secondary patency rates at 1, 3, and 6 months, and also at 1 year were 93.3%, 91.1%, 86.7%, and 86.7%, respectively. Conclusion: Our AV access intervention which used a clinch knot with purse-string suture while the guidewire remained in place was both useful and feasible for maintaining temporary hemostasis.


2015 ◽  
Vol 3 (7) ◽  
pp. e453 ◽  
Author(s):  
Stephanie A. Caterson ◽  
Mansher Singh ◽  
Simon G. Talbot ◽  
Elof Eriksson

Author(s):  
Jo Anne Au Yong ◽  
Daniel D. Smeak

Abstract OBJECTIVE To compare 3 anal purse-string suture techniques for resistance to leakage and to identify the suture technique requiring the fewest tissue bites to create a consistent leak-proof orifice closure. ANIMALS 18 large-breed canine cadavers. PROCEDURES 3 purse-string suture techniques (3 bites with 0.5 cm between bites [technique A], 5 bites with 0.5 cm between bites [technique B], and 3 bites with 1.0 cm between bites [technique C]) were evaluated. Each technique involved 2-0 monofilament nylon suture that was placed in the cutaneous tissue around the anus and knotted with 6 square throws. Standardized 2.0-cm-diameter circular templates with the designated bite number and spacing indicated were used for suture placement. Leak-pressure testing was performed, and the pressure at which saline was first observed leaking from the anus was recorded. The median and interquartile (25th to 75th percentile) range (IQR) were compared among 3 techniques. RESULTS Median leak pressure for technique A (101 mm Hg; IQR, 35 to 131.3 mm Hg) was significantly greater than that for technique C (19 mm Hg; IQR, 14.3 to 25.3 mm Hg). Median pressure did not differ between techniques A and B (50 mm Hg; IQR, 32.5 to 65 mm Hg) or between techniques B and C. CLINICAL RELEVANCE Placement of an anal purse-string suture prevented leakage at physiologic colonic and rectal pressures, regardless of technique. Placement of 3 bites 0.5 cm apart (technique A) is recommended because it used the fewest number of bites and had the highest resistance to leakage.


2018 ◽  
Vol 36 (3) ◽  
pp. 218-225 ◽  
Author(s):  
Wen-Ping Wang ◽  
Long-Qi Chen ◽  
Han-Lu Zhang ◽  
Yu-Shang Yang ◽  
Song-Lin He ◽  
...  

Background: Intrathoracic esophagogastrostomy plays an important role in minimally invasive Ivor-Lewis esophagectomy for cancer. Intrathoracic anastomosis with robot-assisted Ivor-Lewis esophagectomy (RAILE) includes hand-sewn and circular stapler methods, which remain technically challenging. In this study, we modified the techniques for intrathoracic anastomosis at RAILE, in order to simplify the complex procedures. Methods: “Side-insertion” technique was used for anvil placement and purse string suture for intrathoracic anastomosis at RAILE. Medical records for consecutive patients who had undergone robot-assisted minimally invasive Ivor-Lewis esophagectomy for cancer between January 2015 and June 2018 were analyzed. Results: A total of consecutive 31 patients were enrolled. There was no conversion to open thoracotomy in this cohort. Mean operation duration in the robotic group was 387.4 ± 68.2 min. Median estimated blood loss was 110 mL (range 50–400 mL). Two patients (6.5%) had postoperative anastomotic leak. No postoperative reoperation was needed and there were no mortality. Six patients (19.4%) had anastomotic stricture and 2 patients of them needed endoscopic dilation. Conclusion: RAILE is safe and feasible. Our modified procedure highlighting the “side-insertion” method may simplify the process of intrathoracic anvil placement and purse string suture for anastomosis at RAILE.


2017 ◽  
Vol 41 (4) ◽  
pp. 806-814 ◽  
Author(s):  
Bishara Atiyeh ◽  
Amir Ibrahim ◽  
Salim Saba ◽  
Raffy Karamanoukian ◽  
Fadl Chahine ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document