Intubation with Airtraq® and bronchial blocker compared with conventional intubation with double-lumen tube in thoracic surgery: Impact on the hemodynamic response

2011 ◽  
Vol 28 ◽  
pp. 236 ◽  
Author(s):  
Idrissi A. Ahamdanech ◽  
Martínez E. Payá ◽  
C. Ribera ◽  
García E. Sánchez ◽  
Carbonell A. Perez ◽  
...  
Author(s):  
Roberto Righetti ◽  
Gianluca Zani ◽  
Marina Diamanti ◽  
Aliza Scaramuzza ◽  
Matilde Papetti ◽  
...  

2021 ◽  
Author(s):  
Wenzhu Wang ◽  
Ji Li ◽  
Jian Liu ◽  
Chengwei Song ◽  
ya-nan Zhang

Abstract Background: Intubation difficulties, hypoxemia, inability to perform a one-lung ventilation, and high airway pressure often occur during double-lumen tube intubation. Tracheal bronchus is a very rare and difficult to find reason. We present a case of tracheal bronchus accidentally discovered during double-lumen tube intubation in a patient undergoing thoracic surgery. We are the first one to summarize the one-lung ventilation strategy for patients with tracheal bronchus. Case Presentation: A 53-year-old man underwent a scheduled thoracoscopic left upper lobectomy. After two unsuccessful attempts to pass the right-sided double-lumen tube through the right mainstem bronchus, fiberoptic bronchoscopy revealed an aberrant tracheal bronchus with an incidence of 0.1%–3%. Finally we used a left-sided DLT to ventilate the right lung. The patient had no airway complications and was discharged 7 days after the operation.Conclusions: This case serves to remind us that preoperative visits must be thorough and careful. Although a computed tomography chest examination was performed before surgery, we just looked at the inspection report and did not look at the images. We also reviewed relevant literature and summarized the one-lung ventilation strategies for patients with tracheal bronchus. For left-lung ventilation, either a left-sided double-lumen tube or a combination of a bronchial blocker and Fogarty artery embolization catheter can be used. For right-lung ventilation, a bronchial blocker or a left-sided double-lumen tube is a good choice.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jerome Defosse ◽  
Mark Schieren ◽  
Torsten Loop ◽  
Vera von Dossow ◽  
Frank Wappler ◽  
...  

Abstract Background The scientific working group for “Anaesthesia in thoracic surgery” of the German Society of Anaesthesiology and Intensive Care Medicine (DGAI) has performed an online survey to assess the current standards of care and structural properties of anaesthesia workstations in thoracic surgery. Methods All members of the European Society of Anaesthesiology (ESA) were invited to participate in the study. Results Thoracic anaesthesia was most commonly performed by specialists/board-certified anaesthetists and/or senior/attending physicians. Across Europe, the double lumen tube (DLT) was most commonly chosen as the primary device for lung separation (461/ 97.3%). Bronchial blockers were chosen less frequently (9/ 1.9%). Throughout Europe, bronchoscopy was not consistently used to confirm correct double lumen tube positioning. Respondents from Eastern Europe (32/ 57.1%) frequently stated that there were not enough bronchoscopes available for every intrathoracic operation. A specific algorithm for difficult airway management in thoracic anaesthesia was available to only 18.6% (n = 88) of the respondents. Thoracic epidural analgesia (TEA) is the most commonly used form of regional analgesia for thoracic surgery in Europe. Ultrasonography was widely available 93,8% (n = 412) throughout Europe and was predominantly used for central line placement and lung diagnostics. Conclusions While certain „gold standards “are widely met, there are also aspects of care requiring substantial improvement in thoracic anaesthesia throughout Europe. Our data suggest that algorithms and standard operating procedures for difficult airway management in thoracic anaesthesia need to be established. A European recommendation for the basic requirements of an anaesthesia workstation for thoracic anaesthesia is expedient and desirable, to improve structural quality and patient safety.


Sign in / Sign up

Export Citation Format

Share Document