A Randomized, Double-blinded Comparison of Phenylephrine and Ephedrine Infusion Combinations to Maintain Blood Pressure During Spinal Anesthesia for Cesarean Delivery: The Effects on Fetal Acid-Base Status and Hemodynamic Control

2009 ◽  
Vol 29 (3) ◽  
pp. 140-141 ◽  
Author(s):  
W. D. Ngan Kee ◽  
A. Lee ◽  
K. S. Khaw ◽  
F. F. Ng ◽  
M. K. Karmakar ◽  
...  
2017 ◽  
Vol 127 (2) ◽  
pp. 241-249 ◽  
Author(s):  
Allison J. Lee ◽  
Ruth Landau ◽  
James L. Mattingly ◽  
Margaret M. Meenan ◽  
Beatriz Corradini ◽  
...  

Abstract Background Current recommendations for women undergoing cesarean delivery include 15° left tilt for uterine displacement to prevent aortocaval compression, although this degree of tilt is practically never achieved. We hypothesized that under contemporary clinical practice, including a crystalloid coload and phenylephrine infusion targeted at maintaining baseline systolic blood pressure, there would be no effect of maternal position on neonatal acid base status in women undergoing elective cesarean delivery with spinal anesthesia. Methods Healthy women undergoing elective cesarean delivery were randomized (nonblinded) to supine horizontal (supine, n = 50) or 15° left tilt of the surgical table (tilt, n = 50) after spinal anesthesia (hyperbaric bupivacaine 12 mg, fentanyl 15 μg, preservative-free morphine 150 μg). Lactated Ringer’s 10 ml/kg and a phenylephrine infusion titrated to 100% baseline systolic blood pressure were initiated with intrathecal injection. The primary outcome was umbilical artery base excess. Results There were no differences in umbilical artery base excess or pH between groups. The mean umbilical artery base excess (± SD) was −0.5 mM (± 1.6) in the supine group (n = 50) versus −0.6 mM (± 1.5) in the tilt group (n = 47) (P = 0.64). During 15 min after spinal anesthesia, mean phenylephrine requirement was greater (P = 0.002), and mean cardiac output was lower (P = 0.014) in the supine group. Conclusions Maternal supine position during elective cesarean delivery with spinal anesthesia in healthy term women does not impair neonatal acid–base status compared to 15° left tilt, when maternal systolic blood pressure is maintained with a coload and phenylephrine infusion. These findings may not be generalized to emergency situations or nonreassuring fetal status.


2015 ◽  
Vol 122 (4) ◽  
pp. 736-745 ◽  
Author(s):  
Warwick D. Ngan Kee ◽  
Shara W. Y. Lee ◽  
Floria F. Ng ◽  
Perpetua E. Tan ◽  
Kim S. Khaw

Abstract Background: During spinal anesthesia for cesarean delivery, phenylephrine can cause reflexive decreases in maternal heart rate and cardiac output. Norepinephrine has weak β-adrenergic receptor agonist activity in addition to potent α-adrenergic receptor activity and therefore may be suitable for maintaining blood pressure with less negative effects on heart rate and cardiac output compared with phenylephrine. Methods: In a randomized, double-blinded study, 104 healthy patients having cesarean delivery under spinal anesthesia were randomized to have systolic blood pressure maintained with a computer-controlled infusion of norepinephrine 5 μg/ml or phenylephrine 100 μg/ml. The primary outcome compared was cardiac output. Blood pressure heart rate and neonatal outcome were also compared. Results: Normalized cardiac output 5 min after induction was greater in the norepinephrine group versus the phenylephrine group (median 102.7% [interquartile range, 94.3 to 116.7%] versus 93.8% [85.0 to 103.1%], P = 0.004, median difference 9.8%, 95% CI of difference between medians 2.8 to 16.1%). From induction until uterine incision, for norepinephrine versus phenylephrine, systolic blood pressure and stroke volume were similar, heart rate and cardiac output were greater, systemic vascular resistance was lower, and the incidence of bradycardia was smaller. Neonatal outcome was similar between groups. Conclusions: When given by computer-controlled infusion during spinal anesthesia for cesarean delivery, norepinephrine was effective for maintaining blood pressure and was associated with greater heart rate and cardiac output compared with phenylephrine. Further work would be of interest to confirm the safety and efficacy of norepinephrine as a vasopressor in obstetric patients.


2015 ◽  
Vol 59 (6) ◽  
pp. 267-268
Author(s):  
Warwick D. Ngan Kee ◽  
Shara W. Y. Lee ◽  
Floria F. Ng ◽  
Perpetua E. Tan ◽  
Kim S. Khaw

Sign in / Sign up

Export Citation Format

Share Document