Fixed Angle Fixation of Distal Radius Fractures Through a Minimally Invasive Approach

2005 ◽  
Vol 9 (3) ◽  
pp. 142-148 ◽  
Author(s):  
Jorge L Orbay ◽  
Amel Touhami ◽  
Carolina Orbay
2011 ◽  
Vol 93 (1) ◽  
pp. 57-60 ◽  
Author(s):  
DC Perry ◽  
DMG Machin ◽  
JA Casaletto ◽  
DJ Brown

INTRODUCTION Rupture of extensor pollicis longus (EPL) tendon is a recognised complication following volar plate fixation of distal radius fractures, usually from attrition caused by prominent screws. We sought to identify the screw holes in some of the most commonly used plates which may precipitate tendon injury. SUBJECTS AND METHODS Three fixed-angle volar locking plates were sequentially positioned into 18 cadaveric arms. A wire was passed through each of the holes in the plates using a locking guide and the dorsal relationships noted. RESULTS Each plate had specific ‘high-risk’ holes which directed the wire towards the EPL groove. The central screw holes appeared mostly implicated in EPL injury. CONCLUSIONS Awareness of ‘high-risk’ holes and appropriate minor alterations in surgical technique may consequently decrease the incidence of EPL irritation and rupture.


2018 ◽  
Vol 2018 ◽  
pp. 1-5
Author(s):  
Kiyohito Naito ◽  
Yoichi Sugiyama ◽  
Mayuko Kinoshita ◽  
Ahmed Zemirline ◽  
Chihab Taleb ◽  
...  

In this study, we performed osteosynthesis for a distal radius fracture using a minimally invasive approach for a patient with skin disorder of the forearm and obtained favorable results. This case report may provide new findings confirming the usefulness of this surgical approach for distal radius fractures. Blister formation on the right forearm was observed in a 53-year-old female who was diagnosed with a distal fracture of the right radius and underwent splinting in a local hospital, and she was referred to our hospital 2 days after the injury. Minimally invasive locking plate osteosynthesis was performed, and there was no skin lesion at this incision site. Postoperatively, there were no complications in soft tissues and the operative scar was almost unrecognizable. We reported volar locking plate osteosynthesis using the minimally invasive approach in a patient with skin disorder of the forearm. Such patients are rarely encountered. However, this minimally invasive approach is extremely useful for utilizing the advantages of volar locking plate fixation without being affected by the soft tissue environment.


Hand ◽  
2017 ◽  
Vol 13 (3) ◽  
pp. 341-345
Author(s):  
Jacob Duncan ◽  
Marc Trzeciak

Background: The Conventus Distal Radius System (DRS) is an intramedullary fixation scaffold inserted into the lateral aspect of the distal radius. The purpose of this study was to identify insertion site anatomy to illustrate risks associated with the minimally invasive nature of radial-sided implant application. Methods: Ten cadavers were utilized. Using fluoroscopy, the 1.1-mm Kirschner wire and template was introduced per manufacturer’s guidelines, access guide assembled, and dissection carried out to the superficial radial nerve (SRN) with preservation of the native location. The access guide marked the insertion location for the side-cut drill. This point was measured in relationship to structures nearby, including the SRN, brachioradialis (BR), lateral antebrachial cutaneous nerve (LABCN), and radial styloid (RS). Results: The large guide contacted the SRN in 4 of 10 cadavers and was volar to it in 6 of 10. When volar, the mean distance was 1.7 mm. The tip of the RS to the large access guide averaged 44.5 mm. The small guide contacted the SRN in 2 of 10, was volar to it in 4 of 10, and between the bifurcation in 4 of 10. When volar, the distance averaged 3.25 mm. When bifurcated, the distance from the small guide to both the dorsal and volar branches was 3.5 mm. The distance from the RS to the small guide averaged 37.8 mm. The LABCN was found in the field of dissection in 4 of 10 cadavers. Conclusions: Several structures are at risk during insertion of the Conventus DRS; thus, knowledge of the relevant anatomy of this minimally invasive approach is crucial to optimize outcomes and patient satisfaction, and to avoid nerve injury.


2005 ◽  
Vol 19 (3) ◽  
pp. 187-191 ◽  
Author(s):  
Frank A. Liporace ◽  
Salil Gupta ◽  
Gerard K. Jeong ◽  
Michael Stracher ◽  
Fredrick Kummer ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document