The Use of Mesh Versus Primary Fascial Closure of the Abdominal Donor Site When Using a Transverse Rectus Abdominus Myocutaneous (TRAM) Flap for Breast Reconstruction

2014 ◽  
Vol 134 ◽  
pp. 26-27 ◽  
Author(s):  
Abhishek Chatterjee ◽  
Dipak Ramkumar ◽  
Tamara B. Dawli ◽  
Mitchell Stotland ◽  
John F. Nigriny ◽  
...  
2018 ◽  
Vol 35 (05) ◽  
pp. 335-340 ◽  
Author(s):  
Sumanas Jordan ◽  
Steven Schulz ◽  
Amanda Carraher ◽  
David Cabiling

Background Abdominal wall morbidity following microvascular breast reconstruction continues to be an area of interest due to both functional and aesthetic concerns. Donor-site closure technique has been shown to affect bulge and hernia rates and ranges from primary closure to various uses of mesh. Few studies to date have compared types of mesh. The present study compares BARD polypropylene to bioabsorbable GORE Bio-A (polyglycolic acid/trimethylene carbonate) mesh used as a fascial underlay with primary fascial closure. Methods A retrospective review of all consecutive deep inferior epigastric artery-based microvascular breast reconstructions, including perforator and muscle-sparing flaps, performed between September 2014 and February 2017 was performed. All patients underwent primary fascial closure with mesh underlay. Risk factors for the formation of an abdominal bulge or hernia were identified by multivariate logistic regression. Results Eighty-seven patients, with 123 abdominal donor sites, were included. Heavy-weight polypropylene mesh was used for 58 donor sites, while polyglycolic acid/trimethylene carbonate mesh was used in 65 donor sites. The overall incidence of bulge or hernia was 11.4%. The bioabsorbable cohort experienced significantly more bulges/hernias than the polypropylene mesh cohort (20% vs. 1.7% by donor site). Time to diagnosis of bulge was longer for the bioabsorbable group (219 ± 107 vs. 69 days). Flap type and perforator row were not associated with bulge/hernia. The polyglycolic acid/trimethylene carbonate mesh was associated with a 13.3-fold risk of bulge/hernia (p = 0.016). Conclusion Polyglycolic acid/trimethylene carbonate mesh is not appropriate for anterior rectus fascia reinforcement following abdominal tissue transfer.


2007 ◽  
Vol 119 (3) ◽  
pp. 788-795 ◽  
Author(s):  
Scott L. Spear ◽  
Ivica Ducic ◽  
Frank Cuoco ◽  
Nathan Taylor

2010 ◽  
Vol 43 (02) ◽  
pp. 166-172
Author(s):  
Chacko Cyriac ◽  
Ramesh Kumar Sharma ◽  
Gurpreet Singh

ABSTRACT Background: The pedicled TRAM flap has been a workhorse of autologous breast reconstruction for decades. However, there has been a rising concern about the abdominal wall donor site morbidity with the use of conventional TRAM flap. This has generally been cited as one of the main reasons for resorting to “abdominal wall friendly” techniques. This study has been undertaken to assess the abdominal wall function in patients with pedicled TRAM flap breast reconstruction. The entire width of the muscle and the overlying wide disk of anterior rectus sheath were harvested with the TRAM flap in all our patients and the anterior rectus sheath defect was repaired by a Proline mesh. Materials and Methods: Abdominal wall function was studied in 21 patients who underwent simultaneous primary unipedicled TRAM flap reconstruction after mastectomy for cancer. In all the patients, the abdominal wall defect was repaired using wide sheet of Proline mesh both as inlay and onlay. The assessment tools included straight and rotational curl ups and a subjective questionnaire. The abdominal wall was also examined for any asymmetry, bulge, or hernia. The minimal follow-up was 6 months postoperative. The objective results were compared with normal unoperated volunteers. Results and Conclusions: The harvesting the TRAM flap certainly results in changes to the anterior abdominal wall that can express themselves to a variable degree. A relatively high incidence of asymptomatic asymmetry of the abdomen was seen. There was total absence of hernia in our series even after a mean follow-up period of 15.5 months. A few patients were only able to partially initiate the sit up movement and suffered an important loss of strength. In most patients, synergists took over the functional movement but as the load increased, flexion and rotation performances decreased. The lack of correlation between exercise tests and the results of the questionnaire suggests that this statistically significant impairment was functionally not important. The patients encountered little or no difficulty in theis day-to-day activities. Our modification of use of a wide mesh as inlay and onlay repair minimizes the donor site morbidity. This also avoids maneuvers meant for primary closure of the rectus sheath defects, which can result in distortion of umbilicus. Therefore, in conclusion, the unipedicled TRAM flap should be regarded as a valuable option in breast reconstruction provided careful repair of the abdominal wall defect is undertaken using Proline mesh.


2014 ◽  
Vol 72 (4) ◽  
pp. 391-397 ◽  
Author(s):  
Luis Antonio Rossetto ◽  
Elvio Bueno Garcia ◽  
Luiz Eduardo Felipe Abla ◽  
Lydia Masako Ferreira

Sign in / Sign up

Export Citation Format

Share Document